Abstract
Digital holographic microscopy (DHM) allows optical-path-difference (OPD) measurements with nanometric accuracy. OPD induced by transparent cells depends on both the refractive index (RI) of cells and their morphology. This Letter presents a dual-wavelength DHM that allows us to separately measure both the RI and the cellular thickness by exploiting an enhanced dispersion of the perfusion medium achieved by the utilization of an extracellular dye. The two wavelengths are chosen in the vicinity of the absorption peak of the dye, where the absorption is accompanied by a significant variation of the RI as a function of the wavelength.
© 2008 Optical Society of America
Full Article | PDF ArticleMore Like This
Benjamin Rappaz, Pierre Marquet, Etienne Cuche, Yves Emery, Christian Depeursinge, and Pierre J. Magistretti
Opt. Express 13(23) 9361-9373 (2005)
Siqing Dai, Jingyu Mi, Jiazhen Dou, Tongyao Yu, Mengmeng Zhang, Jianglei Di, Jiwei Zhang, and Jianlin Zhao
Opt. Lett. 47(9) 2306-2309 (2022)
Florian Charrière, Anca Marian, Frédéric Montfort, Jonas Kuehn, Tristan Colomb, Etienne Cuche, Pierre Marquet, and Christian Depeursinge
Opt. Lett. 31(2) 178-180 (2006)