Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Three-photon absorption in optical parametric oscillators based on OP-GaAs

Open Access Open Access

Abstract

We report on, to the best of our knowledge, the first singly resonant (SR), synchronously pumped optical parametric oscillator (OPO) based on orientation-patterned gallium arsenide (OP-GaAs). Together with a doubly resonant (DR) degenerate OPO based on the same OP-GaAs material, the output spectra cover 3 to 6 μm within 3dB of relative power. The DR-OPO has the highest output power reported to date from a femtosecond, synchronously pumped OPO based on OP-GaAs. We observed strong three-photon absorption with a coefficient of 0.35±0.08cm3/GW2 for our OP-GaAs sample, which limits the output power of these OPOs as mid-IR light sources. We present a detailed study of the three-photon loss on the performance of both the SR- and DR-OPOs, and compare them to those without this loss mechanism.

© 2016 Optical Society of America

Mid-IR frequency combs have emerged as a new generation of spectroscopic tools for molecular science [13] due to their ability to quickly acquire a broadband molecular spectrum with high spectral resolution. High average power frequency combs allow for increased sensitivity and shorter acquisition times. To date, the highest power frequency comb source in the mid-IR beyond 3 μm is a singly resonant optical parametric oscillator (SR-OPO) based on a lithium niobate crystal (transparent out to 5 μm), with >1W average output power [1]. However, frequency comb techniques are currently limited in the fingerprint region beyond 5 μm where no watt-level high-power sources exist [46]. Gallium arsenide (GaAs) is considered a promising material for the generation of mid-IR in the fingerprint region due to its large transparency range from 0.9 to 17 μm (bandgap of 1.42 eV) [7,8], its large nonlinear coefficient of d14=94pm/V (at 4 μm) [9], and the availability of quasi-phase matching (QPM).

In this Letter, we demonstrate the first SR-OPO based on orientation-patterned (OP)-GaAs. We were able to achieve a maximum output power of 11 mW around 5.5 μm at a threshold pump power of 940 mW. The SR-OPO is built around a 470 μm thick OP-GaAs crystal with a QPM period of 58 μm. The crystal was mounted at the Brewster angle and rotated by 35° to the [011] crystallographic direction. This assures the highest nonlinear coefficient along [111] as well as linearly p-polarized light in the signal and idler [9].

A detailed schematic of the SR-OPO is shown in Fig. 1. The resonator is set up as a standing wave cavity that drastically simplifies alignment, at the expense of increased intracavity loss. One of the flat mirrors is used as an input coupler for the pump, and the other flat mirror serves as an output coupler for the generated idler. Both flat mirrors are highly transparent for the pump laser centered around 1.95 μm. The pump laser is a Tm-fiber laser that is amplified to 2 W average output power. The laser has a repetition rate of 110 MHz and a pulse duration of 157 fs (FWHM).

 figure: Fig. 1.

Fig. 1. Setup of the SR- and DR-OPO. A telescope matches a 1.95 μm, 110 MHz mode-locked laser to a standing wave cavity formed by M1–M4. An OP-GaAs crystal is placed at the cavity focus between the focusing mirrors M2 and M3 [radius of curvature (ROC) of 50 mm] with a waist size of 21μm (1/e2 intensity radius). SR-OPO: M1 and M4 highly transmissive (HT) for the pump and highly reflective (HR) for the signal wavelength (2.5–3.1 μm). M4 output couples the idler wavelength (T>85%). DR-OPO: M1 is HR at 3.0–6.6 μm with 80% pump transmission, and M4 is a broadband gold mirror. Light is coupled out of the OPO at the sapphire Brewster plate.

Download Full Size | PDF

With the pump power threshold, Pth, of 940 mW and the available pump power of 1.8 W inside the resonator, our expectation was to generate at least several tens of mW in the mid-IR, as shown by the red dashed line in Fig. 2(a). However, we found a strong saturation of the output power, as evidenced by the measurement (blue circles) in Fig. 2(a).

 figure: Fig. 2.

Fig. 2. Output power versus pump power for (a) the SR-OPO and (b) the DR-OPO. The red dashed lines indicate the output power of the OPOs without 3PA. The blue circles are the measured output power, and the blue solid line is the calculated output power based on our measurements for the 3PA coefficient and the threshold of the OPOs.

Download Full Size | PDF

We identified three-photon absorption (3PA) as a limiting factor for the performance of optical parametric oscillators based on GaAs. Previous measurements of the 3PA coefficient γ yielded a value of 0.35±0.5cm3/GW2 at a wavelength of 2.3 μm and a value of 0.25cm3/GW2 at 2 μm [10].

In order to characterize the exact contribution of 3PA in our system, we measured the 3PA coefficient γ of the OP-GaAs crystal in our setup. The z-scan measurements were carried out according to [11]. The crystal was placed close to perpendicular to the incident beam and the polarization had an angle of 35° to the [011] crystallographic direction. The pulse duration of the amplified mode-locked Tm-fiber laser was measured with the frequency-resolved optical gating technique. The wavelength of the laser is centered around 1.95 μm, which corresponds to 44% of the bandgap of GaAs. The spot size in the focus was 15.6±0.4μm (1/e2 intensity radius) and was determined from the fit parameters of the z-scan. This leads to a peak on-axis intensity of 10±1GW/cm2. Since the OP-GaAs crystal was not anti-reflection coated we corrected the incident power for the Fresnel reflection on the surface. A z-scan measurement in the patterned region of the GaAs crystal is shown in Fig. 3. We analyzed the z-scan data according to [10,11] and determined that 3PA is indeed the dominant absorption mechanism at our pump wavelength of 1.95 μm.

 figure: Fig. 3.

Fig. 3. Top: Z-scan measured in the patterned region of a 58 μm QPM-period OP-GaAs crystal. This measurement reveals a 3PA coefficient of 0.35±0.08cm3/GW2. Bottom: microscope image of the measured crystal. Typical OP-GaAs crystals offer a 2 mm by 1 mm surface area and a thickness around 500 μm.

Download Full Size | PDF

We measured the three-photon coefficient in our OP-GaAs crystal (58 μm pattern) to be 0.30±0.08cm3/GW2 in the substrate, and 0.35±0.08cm3/GW2 in the patterned region of the crystal. The increased values for the 3PA coefficient in the patterned region might be due to the existence of midgap states in GaAs [12], or an increased free-carrier lifetime in hydride vapor phase epitaxy grown samples due to the absence of defect states that decrease carrier lifetimes [13].

The 3PA coefficient of GaAs is high compared to, for example, the 3PA coefficient of ZnO or Si, reported with values of 0.003±0.0015cm3/GW2 [11] and 0.022±0.01cm3/GW2 [14], respectively. Both values were measured with photons carrying an energy of 44% of their respective bandgap (3.3 eV for ZnO and 1.1 eV for Si).

Losses from 3PA have a quadratic dependence on input power. These additional losses will increase the threshold of the OPO. Their influence on the threshold of the OPO can be calculated with the threshold criteria for SR-OPOs under the assumption of perfect phase matching [15,16]:

g2Leff2=2l=2(l0+l3PA).

Leff stands for the effective crystal length, l0 denotes the losses for the signal in the OPO without 3PA, and l3PA is the induced loss due to 3PA. The parametric gain coefficient, g, links the losses to the average pump power, Pav, and is given by the expression [15]

g2=8π2deff2Pavnpnsniλsλicϵ0frepτpw02πτp2τp2+τs2.

Here we assume perfect spatial coupling. np,ns,ni refer to the refractive indices of the pump, signal, and idler. λs and λi refer to their respective wavelengths. τp and τs correspond to the pulse duration of the pump laser and the signal, respectively.

The output power of a SR-OPO can then be expressed as

Pout,3PA=DSR,i(PinPth,3PA)=DSR,i(PinPth,no3PAbPin2),
where DSR,i is the photon conversion efficiency into the idler, and b is calculated numerically via Eqs. (1) and (2) including the measured 3PA loss coefficient. b has a value of 0.31W1 in our system. Clearly, Pth,3PA is input power dependent.

For the SR-OPO, we estimate the losses l0 to be 10.2%, limited mainly by the mirrors used for the OPO cavity. At the threshold of the SR-OPO, we calculate a value of 4.2% for l3PA by using Eq. (6) in Ref. [11]. Here we assume that the 3PA loss (caused by the pump light) carries over to the signal. We used τs as a fitting parameter to self-consistently describe the losses at the threshold and the threshold power, Pth,3PA, of 940 mW. The signal pulse duration is then kept constant. In a second step, we calculate the threshold without 3PA, Pth,no3PA to be 660 mW.

The conversion efficiency DSR,i was adjusted in order to achieve the best fit of the theoretical model to our measured output power. In this way, we find a total photon conversion efficiency DSR of 20%. This corresponds to a conversion efficiency into the idler DSR,i of 7%.

The measured output power versus pump power can be seen in Fig. 2(a). The output power has a maximum of 11 mW and follows a quadratic behavior that is well described by Eq. (3). An idealized SR-OPO with the slope efficiency DSR and without 3PA losses is displayed to highlight the detrimental effect of 3PA in Fig. 2(a). In the absence of 3PA, an output power of 90 mW in the idler is calculated even at our relatively low photon conversion efficiency of 20%. The nondegenerate spectra of signal and idler of the SR-OPO are displayed in Fig. 4.

 figure: Fig. 4.

Fig. 4. Spectra of the pump laser (black circles), the output of DR-OPO (green, inverted pyramids), signal of SR-OPO (blue squares), and the idler of the SR-OPO (red pyramids). The spectrum of the pump laser was measured with a commercial mid-IR spectrometer. The remaining spectra were measured with a monochromator and a mid-IR photodiode.

Download Full Size | PDF

After we understood the limiting factor of 3PA for the SR-OPO, we exchanged the in-coupling and outcoupling mirrors of the OPO to enable doubly resonant (DR) degenerate operation. To enable direct comparison of the two OPOs we kept the mode matching, crystal position, and cavity type identical to the SR case. We exchanged the OP-GaAs crystal for a 510 μm thick, 53 μm QPM period, in order to allow for degenerate operation of the DR-OPO. As in the SR case, the crystal was mounted at the Brewster angle and rotated by 35° with respect to the [011] crystallographic direction.

The pump is coupled into the cavity via a flat input coupling mirror, M1 in Fig. 1, with about 80% pump transmission and high reflectivity from 3.0 to 6.6 μm, supporting the operation of a degenerate DR-OPO. The remaining mirror, M4, is chosen to be another broadband gold-coated mirror. We used a sapphire plate on a rotation stage as an output coupler of variable reflectivity.

The output power, Pout, as a function of pump power, Pin, of the DR-OPO is displayed in Fig. 2(b). The DR-OPO was optimized for output power while maintaining the mode matching and spot size of the SR-OPO by gradually increasing the output coupling losses ηOC to 16.7%. At this relatively high outcoupling rate, we estimate a total loss of about ltot,th=28% for the signal/idler of the OPO at the threshold of operation. We achieved a maximum output power of 137 mW (summed over all four reflections from the sapphire plate) at a pump power of 1.2 W, measured inside the cavity after the input coupling mirror. The output power of the DR-OPO clearly deviates from the expected linear slope [16], see Fig. 2(b).

The linear slope (red dashed line) is the expected output power Pout,no3PA without the inclusion of any power-dependent losses. Its zero crossing is given by the measured threshold, Pth, of the DR-OPO of 100 mW. The slope of this idealized output power is given by photon conversion efficiency, DDR, of 30% (deduced from the measured pump depletion) and the outcoupling rate, ηOC, in relation to the total losses, ltot,th, and has the following form:

Pout,no3PA=DηOCltot,th(PinPth).

Analogously to the SR-OPO, we include the effect of 3PA on the performance of the DR-OPO by first calculating the pump power dependent losses that are introduced into the system. Here we use our measured value for 3PA in OP-GaAs.

The influence of 3PA on the threshold of the DR-OPO can be calculated with the threshold criteria for DR-OPOs under the assumption of perfect phase matching [15,16]:

g2Leff2=l2.

In the case of the DR-OPO, the additional losses due to 3PA will also decrease the outcoupling rate to ηOC/(ltot+l3PA), see Eq. (4).

For the DR-OPO, the mirror M1 (see Fig. 1) had a pump reflectivity of 20%. The remaining mirrors M2–M4 were all gold coated. This led to a slight pump enhancement within the cavity as well as a second pass of the high average power pump light through the GaAs crystal. As in the SR-OPO, the additional pump power dependent losses, l3PA, led to an increased threshold of the DR-OPO, Pth,3PA. Considering these effects, the output power Pout,3PA of the DR-OPO can be expressed as

Pout,3PA=DDRηOCltot+l3PA(PinPth,3PA).

The measured output power versus pump power is displayed in Fig. 2(b), blue open circles. The prediction of Eq. (6) is depicted with a solid blue line. Inclusion of 3PA effects provides good agreement with the measured performance of the DR-OPO.

Instead of a linear increase in output power, we observed saturation behavior due to the increase in losses and the decrease in the relative outcoupling rate. Nevertheless, to the best of our knowledge, the reported output power here is the highest output power ever reported from a femtosecond, synchronously pumped DR-OPO based on OP-GaAs [4,5,17]. In the work of Smolski and co-workers [4,17], 3PA is not apparent due to the lower available pump power. In comparison, the output power of our DR-OPO could be further increased by using a ring cavity configuration, and hence reducing the cavity round trip losses and threshold. At our highest available pump power (measured within the OPO cavity) of 1.46 W the losses for the signal/idler wavelength increase from 28% to 41.5%, which reduces the outcoupling rate from 63% down to 40%.

The spectrum of the DR-OPO is displayed in Fig. 4. The degenerate DR-OPO produces a spectrum that spans 600 nm around a central wavelength of 3.9 μm. No effort was undertaken to optimize the intracavity dispersion, but this would increase spectral coverage [17,18].

In this Letter, we have presented what is to our knowledge the first SR-OPO based on OP-GaAs. In addition, we have presented the highest output power of a DR-OPO based on the same nonlinear material. The output power of both the DR-OPO and the SR-OPO could be increased by at least a factor of two by working with a ring cavity. The performance of both the SR- and DR-OPO in high peak power regimes are greatly hindered by the presence of 3PA in GaAs if pumped at wavelengths with photon energies corresponding to a third of its bandgap or higher. In particular, SR-OPOs are very susceptible to intracavity losses. In our case, this meant that the SR-OPO based on OP-GaAs barely met the threshold condition. It did, however, allow us to clearly model and understand its limitations in light of 3PA.

Our results show that for future work on high average power mid-IR light sources in the fingerprint region beyond 5 μm, significant OP-GaAs process improvements will be needed to minimize extrinsic defect contributions to 3PA when pumped with standard wavelengths (Yb- or Tm-based laser systems). Our results also highlight the benefits of gallium phosphide (GaP), a promising new alternative with a higher 2.26 eV bandgap that also allows for QPM. Recently, a study of SR-OPOs based on GaP has been demonstrated by Maidment et al. [19] where the authors extended the wavelength coverage to above 11 μm at several mW of output power. The system was pumped with a 1 μm source of 2 W average power.

Funding

Defense Advanced Research Projects Agency (DARPA) SCOUT; Air Force Office of Scientific Research (AFOSR); National Institute of Standards and Technology (NIST); National Science Foundation (NSF) Physics Frontier Center at JILA.

Acknowledgment

We thank K. Iwakuni, V. O. Smolski, and K. L. Vodopyanov for helpful discussions. O. H. H. is partially supported through an Alexander-von-Humboldt Fellowship. P. B. C. is supported by the NSF GRFP. B. S. and T. Q. B. are supported through the NRC Postdoctoral Fellowship program.

REFERENCES

1. F. Adler, K. C. Cossel, M. J. Thorpe, I. Hartl, M. E. Fermann, and J. Ye, Opt. Lett. 34, 1330 (2009). [CrossRef]  

2. A. Schliesser, N. Picque, and T. W. Hänsch, Nat. Photonics 6, 440 (2012). [CrossRef]  

3. B. Spaun, P. B. Changala, D. Patterson, B. J. Bjork, O. H. Heckl, J. M. Doyle, and J. Ye, Nature 533, 517 (2016). [CrossRef]  

4. V. O. Smolski, S. Vasilyev, P. G. Schunemann, S. B. Mirov, and K. L. Vodopyanov, Opt. Lett. 40, 2906 (2015). [CrossRef]  

5. V. Petrov, Prog. Quantum Electron. 42, 1 (2015). [CrossRef]  

6. B. Metzger, B. Pollard, I. Rimke, E. Büttner, and M. B. Raschke, Opt. Lett. 41, 4383 (2016). [CrossRef]  

7. T. Skauli, P. S. Kuo, K. L. Vodopyanov, T. J. Pinguet, O. Levi, L. A. Eyres, J. S. Harris, M. M. Fejer, B. Gerard, L. Becouarn, and E. Lallier, J. Appl. Phys. 94, 6447 (2003). [CrossRef]  

8. D. N. Nikogosyan, Nonlinear Optical Crystals: A Complete Survey (Springer-Verlag, 2005).

9. P. S. Kuo, K. L. Vodopyanov, M. M. Fejer, X. Yu, J. S. Harris, D. F. Bliss, and D. Weyburne, Opt. Lett. 32, 2735 (2007). [CrossRef]  

10. W. C. Hurlbut, Y.-S. Lee, K. L. Vodopyanov, P. S. Kuo, and M. M. Fejer, Opt. Lett. 32, 668 (2007). [CrossRef]  

11. J. He, Y. Qu, H. Li, J. Mi, and W. Ji, Opt. Express 13, 9235 (2005). [CrossRef]  

12. S. D. Benjamin, H. S. Loka, A. Othonos, and P. W. E. Smith, Appl. Phys. Lett. 68, 2544 (1996). [CrossRef]  

13. L. P. Gonzalez, J. Murray, A. Carpenter, D. Upchurch, J. O. Barnes, P. G. Schunemann, K. Zawilski, and S. Guha, Nonlinear Freq. Gener. Convers. Mater. Devices, Appl. IX 7582, 75821A (2010).

14. S. Pearl, N. Rotenberg, and H. M. van Driel, Appl. Phys. Lett. 93, 131102 (2008). [CrossRef]  

15. M. J. McCarthy and D. C. Hanna, J. Opt. Soc. Am. B 10, 2180 (1993). [CrossRef]  

16. R. W. Boyd, Nonlinear Optics (Academic, 1992).

17. V. O. Smolski, H. Yang, S. D. Gorelov, P. G. Schunemann, and K. L. Vodopyanov, Opt. Lett. 41, 1388 (2016). [CrossRef]  

18. N. Leindecker, A. Marandi, R. L. Byer, K. L. Vodopyanov, J. Jiang, I. Hartl, M. Fermann, and P. G. Schunemann, Opt. Express 20, 7046 (2012). [CrossRef]  

19. L. Maidment, P. G. Schunemann, and D. T. Reid, Opt. Lett. 41, 4261 (2016). [CrossRef]  

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (4)

Fig. 1.
Fig. 1. Setup of the SR- and DR-OPO. A telescope matches a 1.95 μm, 110 MHz mode-locked laser to a standing wave cavity formed by M1–M4. An OP-GaAs crystal is placed at the cavity focus between the focusing mirrors M2 and M3 [radius of curvature (ROC) of 50 mm] with a waist size of 21 μm ( 1 / e 2 intensity radius). SR-OPO: M1 and M4 highly transmissive (HT) for the pump and highly reflective (HR) for the signal wavelength (2.5–3.1 μm). M4 output couples the idler wavelength ( T > 85 % ). DR-OPO: M1 is HR at 3.0–6.6 μm with 80% pump transmission, and M4 is a broadband gold mirror. Light is coupled out of the OPO at the sapphire Brewster plate.
Fig. 2.
Fig. 2. Output power versus pump power for (a) the SR-OPO and (b) the DR-OPO. The red dashed lines indicate the output power of the OPOs without 3PA. The blue circles are the measured output power, and the blue solid line is the calculated output power based on our measurements for the 3PA coefficient and the threshold of the OPOs.
Fig. 3.
Fig. 3. Top: Z -scan measured in the patterned region of a 58 μm QPM-period OP-GaAs crystal. This measurement reveals a 3PA coefficient of 0.35 ± 0.08 cm 3 / GW 2 . Bottom: microscope image of the measured crystal. Typical OP-GaAs crystals offer a 2 mm by 1 mm surface area and a thickness around 500 μm.
Fig. 4.
Fig. 4. Spectra of the pump laser (black circles), the output of DR-OPO (green, inverted pyramids), signal of SR-OPO (blue squares), and the idler of the SR-OPO (red pyramids). The spectrum of the pump laser was measured with a commercial mid-IR spectrometer. The remaining spectra were measured with a monochromator and a mid-IR photodiode.

Equations (6)

Equations on this page are rendered with MathJax. Learn more.

g 2 L eff 2 = 2 l = 2 ( l 0 + l 3 PA ) .
g 2 = 8 π 2 d eff 2 P av n p n s n i λ s λ i c ϵ 0 f rep τ p w 0 2 π τ p 2 τ p 2 + τ s 2 .
P out , 3 PA = D SR , i ( P in P th , 3 PA ) = D SR , i ( P in P th , no 3 PA b P in 2 ) ,
P out , no 3 PA = D η OC l tot , th ( P in P th ) .
g 2 L eff 2 = l 2 .
P out , 3 PA = D DR η OC l tot + l 3 PA ( P in P th , 3 PA ) .
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.