Abstract
Herein is presented an optical diffraction tomography (ODT) technique for measuring 3-D refractive index (RI) maps of optical plastic lenses. A Mach–Zehnder interferometer was used to measure multiple complex optical fields of a plastic lens immersed in RI-matching oil at various rotational orientations. From this, ODT was used to reconstruct a 3-D RI distribution of the plastic lens with unprecedented RI sensitivity () and high resolution (12.8 μm). As a demonstration, 3-D RI distributions of a 2 mm-diameter borosilicate sphere and a 5 mm-diameter plastic lens were reconstructed. Defects in the lens, generated by pulsed laser ablation, were also detected using the present method.
© 2016 Optical Society of America
Full Article | PDF ArticleMore Like This
KyeoReh Lee, Kyoohyun Kim, Geon Kim, Seungwoo Shin, and YongKeun Park
Opt. Lett. 42(5) 999-1002 (2017)
Walter D. Furlan, Vicente Ferrando, Juan A. Monsoriu, Przemysław Zagrajek, Elżbieta Czerwińska, and Mieczysław Szustakowski
Opt. Lett. 41(8) 1748-1751 (2016)
Jos van Rooij and Jeroen Kalkman
Biomed. Opt. Express 10(4) 1782-1793 (2019)