Abstract
Dispersive pulse-stretching at 2.0 μm has long been hindered by the high intrinsic optical loss from conventional dispersive media. Here a flexible pulse-stretching technique at 2.0 μm is demonstrated over a broad bandwidth with large-scale dispersion and low intrinsic optical loss. The technique employs the newly proposed pulse-stretching scheme, namely, free-space angular-chirp-enhanced delay. Both normal and anomalous temporal dispersion (up to ) with low intrinsic loss () over a spectral bandwidth of at 2.0 μm is obtained with low nonlinear effects. Based on this method, an optical wavelength-swept source at 2.0 μm is realized and applied to spectrally encoded imaging at a line scan rate of , proving the potential of this pulse-stretching technique for continuous single-shot measurements at the 2.0 μm wavelength regime, particularly for optical microscopy and spectroscopy.
© 2017 Optical Society of America
Full Article | PDF ArticleMore Like This
Sisi Tan, Lingxiao Yang, Xiaoming Wei, Can Li, Nan Chen, Kevin K. Tsia, and Kenneth K. Y. Wong
Opt. Lett. 42(8) 1540-1543 (2017)
Sisi Tan, Xiaoming Wei, Bowen Li, Queenie T. K. Lai, Kevin K. Tsia, and Kenneth K. Y. Wong
Opt. Lett. 43(16) 3822-3825 (2018)
Yiqing Xu and Stuart G. Murdoch
Opt. Lett. 44(15) 3697-3700 (2019)