Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

In vitro glucose concentration measurement by a reusable enzymatic glucose sensor and a highly stable circular heterodyne polarimeter

Not Accessible

Your library or personal account may give you access

Abstract

A reliable glucose concentration measurement system was proposed that consisted of a circular heterodyne polarimeter and a reusable enzymatic sensor. The circular heterodyne polarimeter was constructed using a highly stable circular heterodyne light source and a compact alignment-free apparatus that provided phase stability of less than 1° within 20 min. The reusable enzymatic glucose sensor can be reused more than 100 times and retain 90% of its initial performance under optimum storage conditions within a month. The proposed method can be used to determine glucose concentrations in aqueous solutions and human serum. The optimum resolution of the proposed method was approximately 0.88 mg/dl for the glucose solution and 0.68 mg/dl for the serum-based sample.

© 2021 Optical Society of America

Full Article  |  PDF Article
More Like This
Fabrication of glucose fiber sensor based on immobilized GOD technique for rapid measurement

Ting-Qian Lin, Yin-Lin Lu, and Cheng-Chih Hsu
Opt. Express 18(26) 27560-27566 (2010)

Photothermal microfluidic-assisted self-cleaning effect for a highly reusable SERS sensor

Shaojing Liu, Huiqing Zhong, Zongbao Li, Yu Xu, Xiaowen Hu, Zhidong Zheng, Liu Liu, Pengxin Chen, Xiang Cai, Xiaofang Jiang, Aiping Luo, Jianlin Huang, and Xiaobo Xing
Opt. Lett. 46(19) 4714-4717 (2021)

Interferometric optical sensor for measuring glucose concentration

Kun-Huang Chen, Cheng-Chih Hsu, and Der-Chin Su
Appl. Opt. 42(28) 5774-5776 (2003)

Data Availability

Data underlying the results presented in this Letter are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (6)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (1)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (5)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.