Abstract

We present an erratum to our Letter [Opt. Lett. 40, 4249 (2015) [CrossRef]  ]. This erratum corrects the nuclear Lande factor gI in Eq. (2). After correcting the error, the final ground-state hyperfine splitting frequency of the $^{113}{\rm{C}}{{\rm{d}}^ +}$ ion is determined to be 15199862855.0287(10) Hz.

© 2021 Optica Publishing Group

There was a calculation error in our Letter [1] that we intend to correct in this erratum. The nuclear Lande factor ${g_I}$ in Eq. (2) should be $0.6748(1) \times {10^{- 3}}$. Thus, the second-order Zeeman frequency shift should be 3.57920(76) Hz, and the ground-state hyperfine splitting frequency of $^{113}{\rm{C}}{{\rm{d}}^ +}$ ions in zero magnetic field should be 15199862855.0286 Hz. After correcting the error, the final ground-state hyperfine splitting frequency of the $^{113}{\rm{C}}{{\rm{d}}^ +}$ ion is determined to be 15199862855.0287(10) Hz.

REFERENCE

1. K. Miao, J. W. Zhang, X. L. Sun, S. G. Wang, A. M. Zhang, K. Liang, and L. J. Wang, Opt. Lett. 40, 4249 (2015). [CrossRef]  