Abstract
The pulse signal’s transients and low duty cycle characteristics lead to excessive omission and erroneous amplitude measurement in signal capture. We offer a combined microwave photonics frequency–time mapping and optical delay electrical pulse measurement system. Beneficial from the true delay of a long fiber with several paths, the pulse is extended to have a more significant duty cycle so as to boost the capturing possibility. We adopt the bandpass filter to avoid sampling the low-frequency range, prevent phase noise from affecting the signal measurement, and improve the signal-to-noise ratio (SNR). This solves the phase noise issue induced by multiple optical delay paths. The proof-of-concept experiments conduct that a 25 μs pulse with a 50 μs period is stretched to a continuous wave, and the SNR is improved by 7 dB.
© 2023 Optica Publishing Group
Full Article | PDF ArticleMore Like This
Xin Gui, Siqi He, Yiming Wang, Xuelei Fu, Yongxing Guo, and Zhengying Li
Opt. Lett. 48(7) 1814-1817 (2023)
Matteo Petrini, Seyedmohammad Seyedinnavadeh, Vittorio Grimaldi, Maziyar Milanizadeh, Francesco Zanetto, Giorgio Ferrari, Francesco Morichetti, and Andrea Melloni
Opt. Lett. 48(2) 460-463 (2023)
Langfeng Zhou, Wei Wei, Weilin Xie, and Yi Dong
Opt. Lett. 48(17) 4492-4495 (2023)