Abstract
When performing spatial or temporal laser speckle contrast imaging (LSCI), contrast is generally estimated from localized windows containing limited numbers of independent speckle grains NS. This leads to a systematic bias in the estimated speckle contrast. We describe an approach to determine NS and largely correct for this bias, enabling a more accurate estimation of the speckle decorrelation time without recourse to numerical fitting of data. Validation experiments are presented where measurements are ergodic or non-ergodic, including in vivo imaging of mouse brain.
© 2022 Optica Publishing Group
Full Article | PDF ArticleMore Like This
Shuqi Zheng and Jerome Mertz
Biomed. Opt. Express 13(8) 4118-4133 (2022)
Shuqi Zheng, Sheng Xiao, Lisa Kretsge, Alberto Cruz-Martín, and Jerome Mertz
Opt. Lett. 46(19) 5059-5062 (2021)
Péter Földesy, Máté Siket, Ádám Nagy, and Imre Jánoki
Opt. Express 30(12) 21523-21534 (2022)