Femtosecond timing synchronization at megahertz repetition rates for an x-ray free-electron laser

Open Access Open Access

Abstract

A critical challenge of pump-probe experiments with x-ray free-electron lasers (XFELs) is accurate synchronization of x-ray and optical pulses. At the European XFEL we observed megahertz rate timing jitter of ${24.0} \pm {12.4}\;{\rm fs}$.

Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI.

The emergence of x-ray free-electron lasers (XFELs) operating at photon energies of around 10 keV (hard x-rays) over the past decade has opened up new possibilities for the physical, chemical, and biological sciences due to their high brightness and femtosecond (fs) pulses [1]. These intense and ultrashort x-ray pulses are used to record so-called molecular movies on fs time scales using a pump-probe (PP) measurement to achieve both high temporal and spatial resolution—a necessary step to truly understand the dynamics of matter. One of the greatest difficulties to achieve fs time resolution in PP experiments is the shot-to-shot timing jitter, which can be hundreds of fs in XFELs [2]. Therefore, the temporal resolution of an experiment may be severely limited by the timing jitter if the relative PP delay time is not monitored on a single-shot basis, prohibiting studies of fs dynamics. Unlike other hard x-ray FELs so far, which have been operating at ${\le}120\;{\rm Hz}$, the European XFEL (EuXFEL) has been designed to deliver up to 27,000 pulses per second at megahertz (MHz) repetition rates with burst operation [1]. In order to fully benefit from the increased number of x-ray pulses that the EuXFEL can provide for PP experiments, a unique optical PP laser system was developed to deliver pulses as short as 15 fs with a burst structure matching that of the x-rays while maintaining minimal jitter between the XFEL and the optical laser using an optical synchronization system [3].

Characterization of the PP jitter at MHz repetition rate in the hard x-ray regime, which is presented here, was made possible with the installation of the photon arrival time monitor (PAM) at the Single Particles, Clusters, and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) instrument [4]. The PAM uses the spectral encoding technique that has already been successfully applied at other hard x-ray FELs [5] at up to 120 Hz. A 100 µm thick Ce:YAG was utilized as a target sample. Two GOTTHARD (Gain Optimizing microsTrip sysTem witH Analog ReaDout) detectors [6] operating at 564 kHz recorded alternating optical pulses in each MHz pulse train. Using radiofrequency (RF) pre-lock synchronization [7], the inter-train RMS jitter was measured to be $279 \pm 32\;{\rm fs}$. Figure 1 shows the relative time of arrival of x-ray and optical pulses using the RF and optical synchronization (OS) systems. An extremely low inter-train RMS jitter of 24.0 fs with an uncertainty of 12.4 fs was observed over a period of 10 min using OS [Fig. 1]. Additionally, measurements over a period of 2 h show no significant slow drift while using OS. These results demonstrate a significant advance towards fs PP experiments at MHz repetition rates.

 figure: Fig. 1.

Fig. 1. The black line shows the rolling mean over a 5 s window. The inset shows a histogram of the relative arrival times using 100 x-ray pulses per train (10 Hz inter-train and 1.128 MHz intra-train repetition rates) with RF synchronization (blue, 854,430 pulses) measured using a 3.1 ps temporal window and optical synchronization (red, 431,300 x-ray pulses) measured using a 1.2 ps temporal window.

Download Full Size | PDF

In conclusion, the spectral encoding technique was developed for operation in the hard x-ray regime at a MHz repetition rate. The PP inter- and intra-train timing jitter was characterized at the EuXFEL with optical synchronization. Since the previous report [7], the inter-train RMS jitter has been reduced by 1 order of magnitude, down to 24.0 fs with 12.4 fs uncertainty, which can be attributed to the OS system and improved optical laser beam transport. Furthermore, the intra-train jitter was measured at 1.128 MHz repetition rate using a device that is available for users of the SPB/SFX instrument [Fig. 2]. Our work highlights the importance of the OS for future PP studies at high repetition rate and ultrashort x-ray sources. Owing to the excellent synchronization between the XFEL and the PP laser at EuXFEL, experiments requiring a temporal resolution above 100 fs will not require the conventional “measure and sort” approach and can thus be performed much more readily.

 figure: Fig. 2.

Fig. 2. Arrival time for each pulse with respect to the first pulse in its train when averaging over 5000 x-ray trains. The error bars show the standard deviation for each pulse in the train over a period of about 500 s.

Download Full Size | PDF

Funding

Helmholtz Association Strategic Investment funds; BioXFEL Science and Technology Center (STC-1231306); Max Planck Society for Medical Research; Australian Nuclear Science and Technology Organisation; Australian Research Council Center of Excellence in Advanced Molecular Imaging (CE140100011); Stiftelsen för Strategisk Forskning; Röntgen-Ångström Cluster; Knut och Alice Wallenbergs Stiftelse; Vetenskapsrådet (822-2013-2014); Ministerstvo školstva, vedy, výskumu a športu Slovenskej republiky; Bundesministerium für Bildung und Forschung (05E13GU1, 05K13GU7); Wellcome Trust.

Acknowledgment

We acknowledge European XFEL GmbH in Schenefeld, Germany, for provision of x-ray free-electron laser beamtime at the SPB/SFX instrument, and we thank the instrument group and facility staff for their great assistance. We thank T. Katayama and S. Owada for fruitful discussions.

Disclosures

The authors declare no conflicts of interest.

REFERENCES

1. B. W. J. McNeil and N. R. Thompson, Nat. Photonics 4, 814 (2010). [CrossRef]  

2. J. M. Glownia, K. Gumerlock, H. T. Lemke, T. Sato, D. Zhu, and M. Chollet, J. Synchrotron Radiat. 26, 685 (2019). [CrossRef]  

3. G. Palmer, M. Kellert, J. Wang, M. Emons, U. Wegner, D. Kane, F. Pallas, T. Jezynski, S. Venkatesan, D. Rompotis, E. Brambrink, B. Monoszlai, M. Jiang, J. Meier, K. Kruse, M. Pergament, and M. J. Lederer, J. Synch. Radiat. 26, 328 (2019). [CrossRef]  

4. A. P. Mancuso, A. Aquila, L. Batchelor, R. J. Bean, J. Bielecki, G. Borchers, K. Doerner, K. Giewekemeyer, R. Graceffa, O. D. Kelsey, Y. Kim, H. J. Kirkwood, A. Legrand, R. Letrun, B. Manning, L. Lopez Morillo, M. Messerschmidt, G. Mills, S. Raabe, N. Reimers, A. Round, T. Sato, J. Schulz, C. Signe Takem, M. Sikorski, S. Stern, P. Thute, P. Vagovič, B. Weinhausen, and T. Tschentscher, J. Synch. Radiat. 26, 660 (2019). [CrossRef]  

5. M. R. Bionta, H. T. Lemke, J. P. Cryan, J. M. Glownia, C. Bostedt, M. Cammarata, J.-C. Castagna, Y. Ding, D. M. Fritz, A. R. Fry, J. Krzywinski, M. Messerschmidt, S. Schorb, M. L. Swiggers, and R. N. Coffee, Opt. Express 19, 21855 (2011). [CrossRef]  

6. A. Mozzanica, A. Bergamaschi, R. Dinapoli, H. Graafsma, D. Greiffenberg, B. Henrich, I. Johnson, M. Lohmann, R. Valeria, B. Schmitt, and S. Xintian, J. Instrum. 7, C01019 (2012). [CrossRef]  

7. H. J. Kirkwood, R. Letrun, T. Tanikawa, J. Liu, M. Nakatsutsumi, M. Emons, T. Jezynski, G. Palmer, M. Lederer, R. Bean, J. Buck, S. D. D. Cafisio, R. Graceffa, J. Grünert, S. Göde, H. Höppner, Y. Kim, Z. Konopkova, G. Mills, M. Makita, A. Pelka, T. R. Preston, M. Sikorski, C. M. S. Takem, K. Giewekemeyer, M. Chollet, P. Vagovič, H. N. Chapman, A. P. Mancuso, and T. Sato, Opt. Lett. 44, 1650 (2019). [CrossRef]  

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (2)

Fig. 1.
Fig. 1. The black line shows the rolling mean over a 5 s window. The inset shows a histogram of the relative arrival times using 100 x-ray pulses per train (10 Hz inter-train and 1.128 MHz intra-train repetition rates) with RF synchronization (blue, 854,430 pulses) measured using a 3.1 ps temporal window and optical synchronization (red, 431,300 x-ray pulses) measured using a 1.2 ps temporal window.
Fig. 2.
Fig. 2. Arrival time for each pulse with respect to the first pulse in its train when averaging over 5000 x-ray trains. The error bars show the standard deviation for each pulse in the train over a period of about 500 s.