Subnanosecond mJ eye-safe laser with an intracavity optical parametric oscillator in a shared resonator

Open Access Open Access

Abstract

We theoretically verify that the threshold of an intracavity optical parametric oscillator pumped by a passively Q-switched laser is entirely controlled by the bleach of the saturable absorber not by the signal output reflectivity. We use a series of different output couplers to optimize the output performance. With a signal output reflectivity of 15%, we experimentally achieve an efficient subnanosecond eye-safe laser with 3.3 mJ pulse energy and 1.5 MW peak power.

©2009 Optical Society of America

1. Introduction

Human exposure is usually inevitable in many applications such as laser radar, remote sensing, rangefinder, target designation, and laser countermeasures; consequently, protection again injury of the eye is one of the most important issues [1–3]. Since water absorption in eye tissue and the intraocular fluid prevents light in the spectral range of 1.4–1.8 μm from reaching the retina, there is a considerable interest in compact laser sources with wavelengths in this eye-safe regime. One of the most promising approaches for high-peak-power eye-safe laser sources is based on intracavity optical parametric oscillators (OPO) [4–15]. The advent of high damage threshold nonlinear crystals and diode-pumped Nd-doped lasers leads to a renaissance of interest in intracavity OPO’s. In recent years, a number of efficient eye-safe intracavity OPOs pumped by actively [5–7] or passively [8–10] Q-switched Nd-doped lasers have been demonstrated to produce pulse energies of tens of μJ with pulse peak powers of 1–100 kW. Nevertheless, eye-safe laser systems with pulse energies in the mJ range and peak powers greater than MW are indispensable for the many long-distance applications [11–15].

The intracavity OPOs are mostly constructed with the coupled cavity configuration in which the resonators for the signal and fundamental wave fields are separate. Recently, it was found [16,17] that the shared cavity configuration in which the pump and signal beams share the same resonator provides a substantially superior amplitude stability, in comparison with the coupled cavity configuration. Even so, the maximum peak power in a shared cavity is usually several times lower than that in a coupled cavity under the circumstance of the same output coupler. Therefore, it is a practical interest to explore an intracavity OPO in a shared resonator in quest of optimal pulse energies and peak powers.

Here, for what is believed to be the first time, a subnanosecond mJ eye-safe laser is experimentally demonstrated with an intracavity OPO pumped in a shared resonator. We first confirm that the threshold of an intracavity OPO pumped by a passively Q-switched laser is essentially determined by the bleach of the saturable absorber not by the signal output reflectivity. As a result, a series of different output couplers are used to ascertain the design criteria for the output optimization. With a signal output reflectivity of 15%, we realize an efficient subnanosecond eye-safe laser with 3.3 mJ pulse energy and 1.5 MW peak power.

2. Experimental setup

Figure 1 shows the experimental setup for an intracavity OPO pumped by a high-power quasi-continuous-wave (QCW) diode-pumped passively Q-switched Nd:YAG laser in a shared resonator. The fundamental laser cavity was formed by a coated Nd:YAG crystal and an output coupler. The OPO cavity entirely overlapped with the fundamental laser cavity. The pump source is a high-power QCW diode stack (Quantel Laser Diodes) that consists of three 10-mm-long diode bars generating 130 W per bar, for a total of 390 W at the central wavelength of 808 nm. The diode stack is designed with 0.4 mm spacing between the diode bars so the overall area of emission is approximately 10 mm (slow axis) × 0.8 mm (fast axis). The full divergence angles in the fast and slow axes are approximately 35° and 10°, respectively. A lens duct was exploited to couple the pump light from the diode stack into the laser crystal. The lens duct has the benefits of simple structure, high coupling efficiency, and unaffected by slight misalignment. The geometric parameters of a lens duct include r, L, H 1, H 2, and H 3, where r is the radius of the input surface, L is the length of the duct, H 1 is the width of the input surface, H 2 is the width of the output surface, and H 3 is the thickness of the duct [18, 19]. Here a lens duct with the parameters of r = 10 mm, L = 32 mm, H 1 = 12 mm, H 2 = 2.7 mm, and H 3 = 2.7 mm was manufactured and used in the experiment. The coupling efficiency of this lens duct is found to be approximately 85%.

 figure: Fig. 1.

Fig. 1. Experimental setup for an intracavity OPO pumped by a high-power QCW diode-pumped passively Q-switched Nd:YAG laser in a shared resonator.

Download Full Size | PDF

The gain medium was a 1.0 at. % Nd:YAG crystal with a diameter of 5 mm and a length of 10 mm. The incident surface of the laser crystal was coated to be highly reflective at 1064 nm and 1573 nm (R>99.8%) and highly transmitted at the pump wavelength of 808 nm (T>90%). The other surface of the laser crystal was coated to be antireflective at 1064 nm and 1573 nm (R<0.2%). The nonlinear material for the intracavity OPO was an x-cut KTP crystal with a size of 4×4×20 mm3. The saturable absorber for the passive Q-switching was a Cr4+:YAG crystal with a thickness of 3 mm and an initial transmission of 60% at 1064 nm. Both surfaces of the KTP and Cr4+:YAG crystals were coated for antireflection at 1573 nm and 1064 nm. All crystals were wrapped with indium foil and mounted in conductively cooled copper blocks. The output coupler had a dichroic coating that was highly reflective at 1064 nm (R > 99.8%) and partially reflective at 1573 nm. Several output couplers with different reflectivities (10% ≤ Rs ≤ 70%) at 1573 nm were used in the experiment to investigate the output optimization. The total cavity length was approximately 5.5 cm. The pulse temporal behavior at 1063 nm and 1571 nm was recorded by a LeCroy digital oscilloscope (Wavepro 7100; 10 G samples/sec; 1 GHz bandwidth) with a fast InGaAs photodiode. The spectral information was monitored by an optical spectrum analyzer (Advantest Q8381A) that employs a diffraction grating monochromator to for measure highspeed light pulses with the resolution of 0.1 nm. In all investigations, the diode stack was driven to emit optical pulses 250 μs long, at a repetition rate less than 40 Hz, with a maximum duty cycle of 1%.

3. Theoretical analysis

The advantage of the intracavity OPO mainly consists in the exploit of high photon density of the fundamental wave. First of all, we analyze the maximum value of the intracavity photon density for the fundamental wave in a passively Q-switched laser. Next, we verify that the intracavity photon density of the present laser cavity can generally exceed the threshold of a singly resonant intracavity OPO by far, even though the reflectivity of the output mirror at the signal wavelength is nearly zero. In a passively Q-switched laser with a fast Q-switching condition, the maximum value of the intracavity photon density of the fundamental wave can be expressed as [20]

ϕf,max=lgmlcav{nint[1+ln(nint)]}

where ni=12σlgm[ln(1/To2)+ln(1/R)+L];nt=12σlgm[βln(1/To2)+ln(1/R)+L];β=σes;σgsni is the initial population density in the gain medium; σ is the stimulated emission cross section of the gain medium; lgm is the length of the gain medium; lcav is the cavity length; To is the initial transmission of the saturable absorber; σgs and σes are the ground-state and excited-state absorption cross sections in the saturable absorber, respectively; R is the reflectivity of the output mirror at the fundamental wavelength; and L is the nonsaturable intracavity round-trip loss. With the properties of the Nd:YAG and Cr4+:YAG crystals and the typical cavity parameters: σ = 2.8×10-19cm , σgs = 8.7×10-19 cm , σes = 2.2×10-19 cm , lcav = 5.5 cm, R = 99.8%, To = 0.6, and L = 0.01, it can be found that ϕ f,max can be up to 1.56×1017 cm-3.

With Brosnan and Byer’s equation [21], the threshold photon density for the double-pass pumped, single resonant OPO is derived to be given by

ϕf,th(Rs)=1.12Ggs(1+γ)2[33lcavcτp+ln(1Rs)+Ls+ln4]2

with the gain coefficient

G=2ħω3ω1ω2deff2lnl2n3n1n2ε0c2

where gs is the mode coupling coefficient, γ is the ratio of backward to forward pump amplitude in the cavity; ω 1, ω 2 and ω 3 are the signal, idler and pump frequencies, respectively;, n 2 and n 3 are the refractive indices at the signal, idler and pump wavelengths, respectively; τp is the FWHM of the pump pulse; deff is the effective non-linear coefficient; ε0 is the vacuum permittivity; c is the speed of light; lnl is the length of the nonlinear crystal; L s is the round-trip signal wave intensity loss in the cavity; and R s is the output reflectivity at the signal wavelength.

Figure 2 depicts the calculated results for the dependence of the threshold photon density ϕf,th(R s) on the output reflectivity R s with the properties of the KTP crystal and the typical cavity parameters: ω 1 = 1.198×1015 sec-1, ω 2 = 5.712×1014 sec-1, ħω 3 = 1.865×10-19 J, deff = 3.64 pm/V, lnl = 20 cm, n 1 = 1.737 n 2 = 1.771, n 3 = 1.748, ε0 = 8.854 pF/m, L s = 0.01, γ = 0.9, gs = 0.9, τp = 10 ns and c = 3×108 m/s. It can be seen that the threshold photon density ϕf,th increases from 6×10 cm-3 to 6×1016 cm-3 for the reflectivity R s varying from 99.9% to 0.1%. As analyzed earlier, the obtainable intracavity photon density of the fundamental wave generally exceeds 1017 cm-3. Therefore, the intracavity OPO for any value of Rs can be promisingly generated in the shared cavity, as long as the pump energy can excite the fundamental wave to bleach the saturable absorber and to overcome the lasing threshold.

 figure: Fig. 2.

Fig. 2. Calculated results for the dependence of the threshold photon density on the output reflectivity R s.

Download Full Size | PDF

4. Experimental results and discussions

Figure 3 shows the experimental results for the threshold pump energy versus the OPO output reflectivity. Experimental results confirm that the threshold pump energy is determined by the bleach of the saturable absorber not by the signal output reflectivity. Consequently, a wide range of the signal output reflectivity can be used to optimize the output performance. Figure 4 depicts the experimental results for the pulse energy of the signal output versus the signal output reflectivity. The optimal output reflectivity for the output pulse energy can be found to be within R s =40–50%. With the optimum output coupler, the conversion efficiency from the diode input energy to the signal output energy is approximately 7%, which is slightly superior to the efficiency of 4–6% obtained in a coupled cavity [15].

 figure: Fig. 3.

Fig. 3. Experimental results for the threshold pump energy versus the OPO output reflectivity.

Download Full Size | PDF

 figure: Fig. 4.

Fig. 4. Experimental results for the pulse energy of the signal output versus the OPO output reflectivity.

Download Full Size | PDF

Figures 5(a)–(c) show the experimental results for the temporal shapes of the fundamental and the signal pulses obtained with three different output couplers. It can be seen that the pulse durations of the signal output are 4.4 ns, 2.1 ns, and 0.85 ns for R s=60%, 50%, and 15%, respectively. The pulse width obtained with R s = 15% is 2.4 times shorter than that obtained with R s = 50%; however, the pulse energy is only 20% less than the maximum value. In other words, the peak power reached with R s = 15% can be nearly two times higher than that obtained with R s = 50%. To be more accurate, the output peak was calculated with the experimental pulse energy and the numerical integration of the measured temporal pulse profile. Figure 6 depicts the experimental results for the peak power of the signal output versus the OPO output reflectivity. The optimal output reflectivity for the output peak power can be found to be within R s =10–20%. With the optimum output coupler, the maximum peak power can be up to 1.5 MW.

 figure: Fig. 5.

Fig. 5. Experimental results for the temporal shapes of the fundamental and the signal pulses.

Download Full Size | PDF

 figure: Fig. 6.

Fig. 6. experimental results for the peak power of the signal output versus the OPO output reflectivity.

Download Full Size | PDF

5. Summary

In summary, we have theoretically and experimentally explored the output performance of an intracavity OPO in a shared cavity configuration. The threshold of an intracavity OPO pumped by a passively Q-switched Nd:YAG laser has been verified to be utterly controlled by the bleach of the saturable absorber not by the signal output reflectivity. Based on thorough experimental studies, we found that an efficient subnanosecond eye-safe laser with 3.3 mJ pulse energy and 1.5 MW peak power could be achieved with a signal output reflectivity of 15%.

Acknowledgments

The authors also thank the National Science Council for their financial support of this research under Contract No. NSC-97-2112-M-009-016-MY3.

References and links

1. E. Gregor, D. E. Nieuwsma, and R. D. Stultz, “20 Hz eyesafe laser rangefinder for air defense,” Proc. SPIE , 1207, 124–134 (1990). [CrossRef]  

2. L. R. Marshall, A. D. Hays, and J. Kasinski, “Highly efficient optical parametric oscillators,” Proc. SPIE 1419, 141–152 (1991). [CrossRef]  

3. J. E. Nettleton, B. W. Schilling, D. N. Barr, and J. S. Lei, “Monoblock laser for a low-cost, eyesafe, microlaser range finder,” Appl. Opt. 39, 2428–2432 (2000). [CrossRef]  

4. T. Debuisschert, J. Raffy, J. P. Pocholle, and M. Papuchon, “Intracavity optical parametric oscillator: Study of the dynamics in pulsed regime,” J. Opt. Soc. Am. B 13, 1569–1587 (1996). [CrossRef]  

5. Z. Liu, Q. Wang, X. Zhang, Z. Liu, J. Chang, H. Wang, S. Fan, W. Sun, G. Jin, X. Tao, S. Zhang, and H. Zhang, “Efficient acoustic-optically Q-switched intracavity Nd:YAG/ KTiOAsO4 parametric oscillator,” Appl. Phys. B 92, 37–41 (2008). [CrossRef]  

6. H. T. Huang, J. L. He, X. L. Dong, C. H. Zuo, B. T. Zhang, G. Qiu, and Z. K. Liu, “High-repetition-rate eye-safe intracavity KTA OPO driven by a diode-end-pumped Q-switched Nd:YVO4 laser,” Appl. Phys. B 90, 43–45 (2008). [CrossRef]  

7. Y. F. Chen, S. W. Chen, S. W. Tsai, and Y. P. Lan, “High repetition-rate eye-safe optical parametric oscillator intracavity pumped by a diode-pumped Q-switched Nd:YVO4 laser,” Appl. Phys. B 76, 263–266 (2003). [CrossRef]  

8. J. Miao, J. Peng, B. Wang, H. Tan, and H. Bian, “Compact low threshold Cr:YAG passively Q-switched intracavity optical parametric oscillator,” Opt. Commun. 281, 2265–2270 (2008). [CrossRef]  

9. Y. F. Chen, S. W. Chen, Y. C. Chen, Y. P. Lan, and S. W. Tsai, “Compact efficient intracavity optical parametric oscillator with a passively Q-switched Nd:YVO4/Cr4+:YAG laser in a hemispherical cavity,” Appl. Phys. B 77, 493–495 (2003). [CrossRef]  

10. Y. F. Chen, S. W. Chen, L. Y. Tsai, Y. C. Chen, and C. H. Chien, “Efficient subnanosecond intracavity optical parametric oscillator pumped with a passively Q-switched Nd:GdVO4 laser,” Appl. Phys. B 79, 823–825 (2004). [CrossRef]  

11. R. Dabu, C. Fenic, and A. Stratan, “Intracavity pumped nanosecond optical parametric oscillator emitting in the eye-safe range,” Appl. Opt. 40, 4334–4340 (2001). [CrossRef]  

12. Y. Yashkir and H. M. van Driel, “Passively Q-switched 1.57-μm intracavity optical parametric oscillator,” Appl. Opt. 38, 2554–2559 (1999). [CrossRef]  

13. A. Agnesi, S. Dell’Acqua, and G. Reali, “Diode-pumped quasi-cw intracavity optical parametric oscillator at 1.57 μm with efficient pulse shortening,” Appl. Phys. B 70, 751–753 (2000).

14. W. Zendzian, J. K. Jabczynski, and J. Kwiatkowski, “Intracavity optical parametric oscillator at 1572-nm wavelength pumped by passively Q-switched diode-pumped Nd:YAG laser,” Appl. Phys. B 76, 355–358 (2003). [CrossRef]  

15. B. W. Schilling, S. R. Chinn, A. D. Hays, L. Goldberg, and C. W. Trussell, “End-pumped 1.5 μm monoblock laser for broad temperature operation,” Appl. Opt. 45, 6607–6615 (2006). [CrossRef]   [PubMed]  

16. Y. F. Chen and L. Y. Tsai, “Comparison between shared and coupled resonators for passively Q-switched Nd:GdVO4 intracavity optical parametric oscillators,” Appl. Phys. B 82, 403–406 (2006). [CrossRef]  

17. Y. F. Chen, K. W. Su, Y. T. Chang, and W. C. Yen, “Compact efficient eye-safe intracavity optical parametric oscillator with a shared cavity configuration,” Appl. Opt. 46, 3597–3601 (2007). [CrossRef]   [PubMed]  

18. R. J. Beach, “Theory and optimization of lens ducts,” Appl. Opt. 35, 2005–2015 (1996). [CrossRef]   [PubMed]  

19. R. Fu, G. Wang, Z. Wang, E. Ba, G. Mu, and X. Hu, “Design of efficient lens ducts,” Appl. Opt. 37, 4000–4003 (1998). [CrossRef]  

20. J. J. Degnan, “Optimization of passively Q-switched lasers,” IEEE J. Quantum Electron. , vol. 31, pp. 1890–1901, 1995. [CrossRef]  

21. S. J. Brosnan and R. L. Byer, “Optical parametric oscillator threshold and linewidth studies,” IEEE J. Quantum Electron. , vol. 15, pp. 415–431, 1979. [CrossRef]  

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (6)

Fig. 1.
Fig. 1. Experimental setup for an intracavity OPO pumped by a high-power QCW diode-pumped passively Q-switched Nd:YAG laser in a shared resonator.
Fig. 2.
Fig. 2. Calculated results for the dependence of the threshold photon density on the output reflectivity R s.
Fig. 3.
Fig. 3. Experimental results for the threshold pump energy versus the OPO output reflectivity.
Fig. 4.
Fig. 4. Experimental results for the pulse energy of the signal output versus the OPO output reflectivity.
Fig. 5.
Fig. 5. Experimental results for the temporal shapes of the fundamental and the signal pulses.
Fig. 6.
Fig. 6. experimental results for the peak power of the signal output versus the OPO output reflectivity.

Equations (3)

Equations on this page are rendered with MathJax. Learn more.

ϕ f , max = l gm l cav { n i n t [ 1 + ln ( n i n t ) ] }
ϕ f , th ( R s ) = 1.12 G g s ( 1 + γ ) 2 [ 33 l cav c τ p + ln ( 1 R s ) + L s + ln 4 ] 2
G = 2 ħ ω 3 ω 1 ω 2 d eff 2 l nl 2 n 3 n 1 n 2 ε 0 c 2
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.