We correct a formula calculating the velocity dynamics. Furthermore we correct a table showing minimum and maximum detectable velocities for specific detector line rates. Our previous results as well as conclusions remain unchanged.
©2009 Optical Society of America
In the article [1], section 3.1 we presented a formula calculating the velocity dynamics of detectable flow speeds, with switched nominator and denominator. The correct formula reads 2vmax/vmin = 2π/ΔΦerr.
In addition we changed Table 1 in section 3.3 showing detectable flow speeds for given detector line rates. In [1] we used the exposure time instead of the line period for the calculations of minimum and maximum detectable flow velocities. The resulting velocities are corrected and a column showing the detector line period T is added. The corrected table is shown in Table 1.