Spontaneous emission of a nanoscopic emitter in a strongly scattering disordered medium

Open Access Open Access

Abstract

Fluorescence lifetimes of nitrogen-vacancy color centers in individual diamond nanocrystals were measured at the interface between a glass substrate and a strongly scattering medium. Comparison of the results with values recorded from the same nanocrystals at the glass-air interface revealed fluctuations of fluorescence lifetimes in the scattering medium. After discussing a range of possible systematic effects, we attribute the observed lengthening of the lifetimes to the reduction of the local density of states. Our approach is very promising for exploring the strong three-dimensional localization of light directly on the microscopic scale.

©2010 Optical Society of America

The behavior of electromagnetic waves in disordered media has been a subject of intense studies in the past decade [1, 2, 3, 4, 5, 6]. In particular, the regime of strong scattering where the mean free path of a photon becomes comparable to its wavelength has fascinated scientists. In such systems, constructive and destructive interference can lead to the modification of the local density of states (LDOS) in various spatial modes and to the localization of light [7, 8, 9]. In an ideal “gedanken” experiment, one might imagine to map the fluctuations of LDOS directly at the subwavelength level. However, so far, light scattering phenomena have been studied via transmission and reflection intensity measurements on macroscopic samples, where separation of the effects of absorption and scattering has posed a challenge [1, 6, 3, 2, 10]. In this work, we probe the variations of LDOS by measuring the modification of the spontaneous emission rate of individual nanoscopic emitters. Our experimental strategy is to characterize the fluorescence decay of each emitter first and then trace its change after covering them by a scattering disordered medium.

As emitters, we used nitrogen-vacancy (NV) color centers in diamond nanocrystals (DNC). The size of the DNCs ranged between 10 and 500 nm with an average size of 60 nm, as measured by electron microscopy. The DNCs were treated by irradiation with 1.5 MeV electrons during 8 hours with a total dose of 3 1018 e/cm2. Annealing at 850 C for 4 hours resulted in approximately 1–10 NV color centers in each DNC. Aside from having a high quantum yield, our choice of emitter has two crucial advantages. First, NV centers in diamond are indefinitely photostable so that repeated quantitative measurements can be performed. Second, the color centers are well protected in the diamond lattice against surface effects upon contact with other material [11].

Our scattering sample consisted of a powder of rutile TiO2 particles (DuPont, Ti-Pure R706) with a mean size of 250 nm and a distribution of 150–350 nm as revealed by electron microscopy. Particles were coated with silica (SiO2, 3 wt %) and alumina (Al2O3 2.5 wt %) and had a refractive index of 2.8 [3]. We produced a disordered medium in half space by sprinkling the powder on a cover glass carrying the DNCs. We then compressed the powder manually by applying a gentle pressure via another glass cover slide. The final thickness of the medium was typically about 0.4 mm. Based on the volume and weight of the material that was deposited, we estimated the volume fraction occupied by particles in the compressed powder to be about 30%.

 figure: Fig. 1.

Fig. 1. a) Schematics of the experimental setup. BS, 50/50 beam splitter; DM, dichroic mirror; PS, piezoelectric scanner; PMT, photomultiplier tube; F, long pass filter; APD, avalanche photodiode; TCSPC, time correlated single photon counting card. b–d) Sample arrangements for diamond nanocrystals exposed to air, water, and TiO2 particles.

Download Full Size | PDF

The schematics of the experiment are shown in Fig. 1. The sample was placed on a three-dimensional piezoelectric stage of a home-built microscope. Laser pulses at a wavelength of 532 nm, duration of 13 ps, and repetition rate of 3.8 MHz were used to excite the NV centers. This light was sent to a microscope objective (NA=1.4) via a 50/50 beam splitter. The scattering and fluorescence from the sample were collected through the same objective, separated via a dichroic mirror and two 540 nm long pass filters, and directed to a photomultiplier tube and an avalanche photodiode, respectively. Fluorescence lifetimes were determined with a time-correlated single-photon counter by recording the time delay between the excitation pulses and the detected photons. The intensity I measured on the photomultiplier tube resulted from the interference of the light reflected by the sample interface and that scattered by a given nano-object in the focus spot. The details of this interferometric scattering (iSCAT) detection method are described in our previous work [12, 13]. The added value of the iSCAT signal is to visualize nano-objects without the need for a fluorescence signal.

In a first step, the DNCs were spin coated on a glass cover slide (see Fig. 1b) and simultaneously imaged in fluorescence and iSCAT by scanning the sample across the focus of the excitation laser beam. Figure 2a shows an example of a fluorescence map of DNCs while Fig. 2b displays the simultaneously recorded iSCAT image. The latter locates the same DNCs as well as a few other nonfluorescent nanoparticles which are most likely DNCs without color centers.

The second step of the experiment involved the measurement of the excited state lifetime τ for each fluorescent DNC. For NV centers in bulk diamond, τ has been measured to be about 12 ns [14]. It is known, however, that the spontaneous emission rate is slowed down, and thus τ becomes larger in subwavelength dielectric media [15]. Furthermore, as the size of the dielectric medium is decreased, the dependence of the spontaneous emission rate on the shape of the medium as well as the emitter orientation and position becomes less significant [16]. Figure 3a displays a typical example of measurements on a single DNC. This measurement is fitted using a background and a double exponential with 1/e times of 4.2 ± 0.3 ns and 22.8 ± 0.3 ns, respectively. We attribute the deviation from a simple exponential decay to the inhomogeneity of emitting transitions in a single DNC. In particular, the shorter lifetime component is most likely due to quenching effects for some NV centers. A plausible cause of this might be the presence of a thin graphite layer on the DNCs [11]. Another source of inhomogeneity can stem from the coexistence of a transition at 575 nm, which is attributed to the neutral charge state of NV centers, and the usual transition of the negatively-charged center at 637 nm [17]. Indeed, we confirmed the presence of both lines by measuring the emission spectra of individual DNCs. To our knowledge, no data are available on the fluorescence lifetime of the neutral color centers. A third phenomenon that can cause different fluorescence lifetimes in a DNC is the orientation of the transition dipole moments of the individual NV centers with respect to the glass substrate [18]. To examine this effect, we have performed rigorous finite-difference time-domain (FDTD) calculations to compute the variation of the radiative decay rates of emitters in a dielectric nano-object placed on a glass surface [19]. It turns out that for the parameters (indices of refraction, particle size) of relevance to our measurements, τ could vary within a factor of three, depending on the orientation of each emitter and its distance from the interface.

The details of the inhomogeneities in τ are not important to our current work because we will be only interested in its modification when the scattering medium is added. In fact, in what follows we will only investigate the changes of the long-lifetime component of the measurements.

 figure: Fig. 2.

Fig. 2. Fluorescence (a,c) and iSCAT (b,d) images of the same diamond nanoparticles on a glass cover slide in air (a,b) and covered with scattering particles (c,d).

Download Full Size | PDF

 figure: Fig. 3.

Fig. 3. a) Fluorescence decay curve measured from a single nanoparticle. b) Histograms of fluorescence lifetimes at the air-glass interface. c) The spread of the ratio τ w/τ a between the measured lifetimes at the water-glass and air-glass interfaces.

Download Full Size | PDF

 figure: Fig. 4.

Fig. 4. a–f) Data collected on the fluorescence lifetimes of many individual DNCs in three different samples (First row, sample 1; second row, sample 2; third row, sample 3.) measured in air and in the scattering medium. We examined 49, 33, and 33 DNCs in the three studies, respectively.

Download Full Size | PDF

As explained below, while several systematic effects could cause shortening of the fluorescence lifetime, its increase provides a robust evidence for the modification of the density of states in the scattering medium. Figure 3b displays the histogram of this component for DNCs placed on a glass cover slide in air. The variation from 8 ns to 37 ns is in agreement with previous reports [20, 11]. We checked the validity of this attribution by measuring the fluorescence lifetime τ w of the same DNCs after adding water on top of the sample (see Fig. 1c). The change in the radiative lifetime of an emitter is inversely proportional to the refractive index of the environment so we expect τ to be reduced under water. Figure 3c shows a histogram of the resulting values normalized to the lifetimes of each DNC in air. The mean value of τ w/τ a amounts to 0.9, where τ a denotes the fluorescence lifetime at the air-glass interface. This outcome is in very good agreement with the expected value of 0.88 if one considers the refractive index of the surrounding environment to be the average of the refractive indices of the media in the lower and upper halves of the glass-air or glass-water interfaces. Note that we do not have to account for local field effects since the NV centers embedded in the diamond matrix do not experience a change of environment at the molecular level [15].

Once the DNCs were characterized, the water was removed with a micro-pipette and the substrate was left to dry overnight under a gentle stream of nitrogen. In the last phase of the experiment, TiO2 particles were placed on the sample (see Fig. 1d). Figures 2c and d show the fluorescence and iSCAT images in the scattering medium. The individual DNCs are still easily identified via fluorescence, while the scattering image now displays a “speckle” pattern. Figures 4a–f present the measured lifetimes of many DNCs from three different scattering samples (the step with water was omitted for samples 2 and 3). Let us label the fluorescence lifetime in the scattering medium by τ s. As in the case of water immersion, we found a distribution of the normalized fluorescence lifetimes τ s/τ a, indicating both reduction and enhancement of the spontaneous emission rate. However, while in the previous case the average value 〉τ w/τ a〈 < 1, here we find 〉τ s/τ a〈 > 1. In sample 1, for example, fluorescence lifetimes are longer than in air by up to a factor of 1.4 with an ensemble average of 1.1. The histograms of Figs. 4b, d, f reveal variations in the measurements from the three samples. A possible cause of this might be different qualities of powder compression and nanoparticle packing.

The observation of lifetimes longer than in air indicates the reduction of LDOS in the scattering medium. We believe this conclusion is robust against systematic effects. First, opening of non-radiative decay channels, e.g. as a result of contact with the medium, cannot be responsible for this effect since it could only increase the total decay rate γ = γ r + γ nr and therefore lower the lifetime. Second, lengthening of the fluorescence lifetime cannot be explained in the context of a homogeneous medium with an effective index of refraction because addition of high-index TiO2 particles could only increase such an effective refractive index with respect to that of the air-glass interface, and thus, reduce the lifetime. Finally, we verified that the longer fluorescence decay was not the result of photon trapping in the scattering medium. To do this, we focused 10 ps pulses of laser light onto the interface between the cover glass and the scattering medium to mimic the spatial mode of the DNC emission. We then interrogated the temporal profile of the reflected light in a confocal detection arrangement with and without the scattering medium. This allowed us to rule out any pulse lengthening within the time resolution of 0.4 ns.

The experiments reported here can be improved in several ways. First, particle composition and compactification of the scattering medium can be varied and characterized [21]. Second, use of color centers with narrow emission spectrum in the near infrared [22] could simplify the analysis of the density of states in comparison to the broad emission of NV centers [23]. Third, such emitters would make it possible to perform measurements on very strongly scattering media based on large-bandgap semiconductors [24]. Our experiments can also be generalized to three-dimensional samples. To do this, one could use optical fibers that carry single DNCs attached to their ends [25] and place such nanoscopic probes deep into a scattering medium.

The measurements in this work provide the first report of the fluctuations of the spontaneous emission rate in a disordered scattering medium. The extension of our experiments from interfaces to three-dimensional samples will set the ground for studying strong localization of light by monitoring and mapping the variations of the local density of states directly in the coordinate space. This would connect the nanoscopic behavior of light scattering with macroscopic transport studies of light that are commonly performed. Indeed, a recent related manuscript [26] posted after the submission of our work shows the current interest in the use of fluorescence lifetime as a local probe for the optics of random media. An important advantage in this approach is that observation of the inhibition of spontaneous emission rules out systematic effects caused by absorption since those would always lead to a reduction of the fluorescence lifetime. Finally, we hope that further theoretical progress in modeling the modification of radiative effects in strongly scattering media will allow quantitative comparisons with experimental data.

We thank H. Eghlidi for help with electron microscopy, P. Kukura for help with the scattering detection and the data acquisition software, and X. Chen for the FDTD calculations. V.S. acknowledges illuminating discussions with R. Carminati and A. Dogariu.

References and links

1. D. S. Wiersma, P. Bartolini, A. Lagendijk, and R. Righini, “Localization of light in a disordered medium,” Nature 390, 671–673 (1997). [CrossRef]  

2. A. A. Chabanov, M. Stoytchev, and A. Z. Genack, “Statistical signatures of photon localization,” Nature 404, 850–853 (2000). [CrossRef]   [PubMed]  

3. M. Störzer, P. Gross, C. M. Aegerter, and G. Maret, “Observation of the Critical Regime Near Anderson Localization of Light,” Phys. Rev. Lett. 96, 063,904 (2006). [CrossRef]  

4. T. Schwartz, G. Bartal, S. Fishman, and M. Segev, “Transport and Anderson localization in disordered two-dimensional photonic lattices,” Nature 446, 52–55 (2007). [CrossRef]   [PubMed]  

5. P. Barthelemy, J. Bertolotti, and D. S. Wiersma, “A Levy flight for light,” Nature 453, 495–498 (2008). [CrossRef]   [PubMed]  

6. C. M. Aegerter and G. Maret, “Coherent Backscattering and Anderson Localization of Light,” Prog. Opt. 52, 1–62 (2009). [CrossRef]  

7. A. D. Mirlin, “Statistics of energy levels and eigenfunctions in disordered systems,” Physics Reports 326, 259–382 (2000). [CrossRef]  

8. H. Schomerus, M. Titov, P. W. Brouwer, and C. W. J. Beenakker, “Microscopic versus mesoscopic local density of states in one-dimensional localization,” Phys. Rev. B 65, 121,101 (2002). [CrossRef]  

9. L. S. Froufe-Perez, R. Carminati, and J. J. Saenz, “Fluorescence decay rate statistics of a single molecule in a disordered cluster of nanoparticles,” Phys. Rev. A 76, 013,835 (2007). [CrossRef]  

10. H. Hu, A. Strybulevych, J. H. Page, S. E. Skipetrov, and B. A. van Tiggelen, “Localization of ultrasound in a three-dimensional elastic network,” Nature Phys. 4, 945–948 (2008). [CrossRef]  

11. J. Tisler, et al., “Fluorescence and Spin Properties of Defects in Single Digit Nanodiamonds,” ACS NANO 3, 1959–1965 (2009). [CrossRef]   [PubMed]  

12. K. Lindfors, T. Kalkbrenner, P. Stoller, and V. Sandoghdar, “Detection and spectroscopy of gold nanoparticle using supercontinuum white light confocal microscopy,” Phys. Rev. Lett. 93, 037,401 (2004). [CrossRef]  

13. P. Kukura, M. Celebrano, A. Renn, and V. Sandoghdar, “Imaging a single quantum dot when it is dark,” Nano Lett. 9, 926–929 (2009). [CrossRef]  

14. A. Collins, M. F. Thomaz, and M. I. B. Jorge, “Luminescence decay time of the 1.945 eV ncentre in type Ib diamond,” J. Phys. C 16, 2177–2181 (1983). [CrossRef]  

15. H. Schniepp and V. Sandoghdar, “Spontaneous Emission of Europium Ions Embedded in Dielectric Nanospheres,” Phys. Rev. Lett. 89, 257,403 (2002). [CrossRef]  

16. L. Rogobete, H. Schniepp, V. Sandoghdar, and C. Henkel, “Spontaneous emission in nanoscopic dielectric particles,” Opt. Lett. 28, 1736–1738 (2003). [CrossRef]   [PubMed]  

17. F. Jelezko and J. Wrachtrup, “Single defect centres in diamond: A review,” Phys. Stat. Sol. A 203, 3207–3225 (2006). [CrossRef]  

18. W. L. Barnes, “Topical review: Fluorescence near interfaces: the role of photonic mode density,” J. Mod. Opt. 45, 661–699 (1998). [CrossRef]  

19. X. Chen and V. Sandoghdar, In preparation.

20. A. Beveratos, R. Brouri, T. Gacoin, J.-P. Poizat, and P. Grangier, “Nonclassical radiation from diamond nanocrystals,” Phys. Rev. A 64, 061,802 (2001). [CrossRef]  

21. G. Popescu and A. Dogariu, “Optical path-length spectroscopy of wave propagation in random media,” Opt. Lett. 24, 442–444 (1999). [CrossRef]  

22. T. Gaebel, I. Popa, A. Gruber, M. Domham, F. Jelezko, and J. Wrachtrup, “Stable single-photon source in the near infrared,” New J. Phys. 6, 98 (2004). [CrossRef]  

23. R. Carminati and J. J. Saenz, “Density of States and Extinction Mean Free Path of Waves in Random Media: Dispersion Relations and Sum Rules,” Phys. Rev. Lett. 102, 093902 (2009). [CrossRef]   [PubMed]  

24. J. G. Rivas, A. Lagendijk, R. W. Tjerkstra, D. Vanmaekelbergh, and J. J. Kelly, “Tunable photonic strength in porous GaP,” Appl. Phys. Lett. 80, 4498–4500 (2002). [CrossRef]  

25. S. Kühn, C. Hettich, C. Schmitt, J.-P. Poizat, and V. Sandoghdar, “Diamond colour centres as a nanoscopic light source for scanning near-field optical microscopy,” J. Microscopy 202, 2 (2001). [CrossRef]  

26. M. D. Birowosuto, S. E. Skipetrov, W. L. Vos, and A. P. Mosk, “Observation of Spatial Fluctuations of the Local Density of States in Random Media,” arXiv:1002.3186v1.

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (4)

Fig. 1.
Fig. 1. a) Schematics of the experimental setup. BS, 50/50 beam splitter; DM, dichroic mirror; PS, piezoelectric scanner; PMT, photomultiplier tube; F, long pass filter; APD, avalanche photodiode; TCSPC, time correlated single photon counting card. b–d) Sample arrangements for diamond nanocrystals exposed to air, water, and TiO2 particles.
Fig. 2.
Fig. 2. Fluorescence (a,c) and iSCAT (b,d) images of the same diamond nanoparticles on a glass cover slide in air (a,b) and covered with scattering particles (c,d).
Fig. 3.
Fig. 3. a) Fluorescence decay curve measured from a single nanoparticle. b) Histograms of fluorescence lifetimes at the air-glass interface. c) The spread of the ratio τ w/τ a between the measured lifetimes at the water-glass and air-glass interfaces.
Fig. 4.
Fig. 4. a–f) Data collected on the fluorescence lifetimes of many individual DNCs in three different samples (First row, sample 1; second row, sample 2; third row, sample 3.) measured in air and in the scattering medium. We examined 49, 33, and 33 DNCs in the three studies, respectively.