Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Adaptive Bayesian algorithm for achieving a desired magneto-sensitive transition

Open Access Open Access

Abstract

Bayesian methods that utilize Bayes’ theorem to update the knowledge of desired parameters after each measurement are used in a wide range of quantum science. For various applications in quantum science, efficiently and accurately achieving a quantum transition frequency is essential. However, the exact relation between a desired transition frequency and the controllable experimental parameters is usually absent. Here, we propose an efficient scheme to search the suitable conditions for a desired magneto-sensitive transition via an adaptive Bayesian algorithm and experimentally demonstrate it by using coherent population trapping in an ensemble of laser-cooled 87Rb atoms. The transition frequency is controlled by an external magnetic field, which can be tuned in realtime by applying a d.c. voltage. Through an adaptive Bayesian algorithm, the voltage can automatically converge to the desired one from a random initial value only after few iterations (N ≥ 10). The response time is limited by the time of obtaining the spectrum signal, which is about 50 s for 10 iterations in our experiment. In particular, when the relation between the target frequency and the applied voltage is nonlinear (e.g., quadratic), our algorithm shows significant advantages over traditional methods. This work provides a simple and efficient way to determine a transition frequency, which can be widely applied in the fields of precision spectroscopy, such as atomic clocks, magnetometers, and nuclear magnetic resonance.

© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

1. Introduction

The Bayesian approach, which relies on updating the knowledge of the probability distribution after each measurement through Bayes’ theorem, can achieve a better precision than that of the frequentist phase estimation [14]. Bayesian methods have been widely used in quantum information applications and experiments, such as quantum phase/frequency estimation [58], quantum state discrimination or estimation [912], Hamiltonian learning [13,14], and quantum computing [15]. Energy levels are the distinctive property of a quantum system, which can be used as a reference for studying its structure. Conversely, it is possible to manipulate the spacings of these energy levels with respect to each other through applying external fields [16]. In order to observe and explore most quantum phenomena, certain desired transitions should be achieved, in which the external fields are required to be tuned in a sophisticated manner [17]. On one hand, the external fields are associated with some specific experimental parameters and their exact relation needs to be determined by fitting a large amount of results. On the other hand, the adjustable range of the experimental parameters are usually very narrow compared to their theoretical predictions. Nevertheless, manually tuning these parameters makes it inconvenient to find the optimal conditions. As one of the notable phenomena, coherent population trapping (CPT) has been extensively studied [1824] and widely used for realizing compact high-precision atomic clocks and magnetometers. CPT is often produced by a two-photon Raman excitation process. At the two-photon resonance, atoms are optically pumped into a dark state, which can be used for frequency estimation. By applying external magnetic fields that act the role of additional control parameters, the magnetic sublevels are split and one can observe magneto-sensitive CPT signals. This magneto-sensitive transition frequency can be used to measure magnetic fields in turn. An essential question therefore arises: is there any efficient way to automatically obtain the suitable experimental parameters for a desired magneto-sensitive transition?

To address this task, machine learning technique is a natural solution [2,2530]. A possible approach towards this kind of optimization is making use of adaptive protocol [2938]. In several adaptive protocols [3,39], Bayesian estimation procedure has been extensively employed. Bayesian estimation is based on the simple premise that probability distribution can be used for describing uncertainty [4,40,41]. According to Bayes’ theorem, the main features can be inferred effectively through updating the probability distribution after each measurement [17,42,43]. The adaptivity can enhance the measurement precision and save experimental resources compared to non-adaptive ones [13,29,30,38,39,43,44].

In this article, we propose an efficient scheme to automatically search a desired magneto-sensitive transition via an adaptive Bayesian algorithm, and experimentally demonstrate it via CPT in an ensemble of laser-cooled $^{87}$Rb atoms. In our experiment, the desired quantum transition is the magneto-sensitive one ( $|F_g=1, m_F=-1\rangle \rightarrow |F_g=2, m_F=-1\rangle$) between the two hyperfine levels of the $5^2 S_{1/2}$ ground state. We use the lin$||$lin CPT configuration to realize a high-contrast of dark resonance. When the frequency difference between the bichromatic field components matches the hyperfine splitting, two-photon dark resonances of $\Lambda$-type systems on the hyperfine levels will be induced. Here, the two-photon resonance of $|F_g=1, m_F=-1\rangle$ and $|F_g=2, m_F=-1\rangle$ is used and its transition is controlled by an external magnetic field. Through an adaptive Bayesian algorithm, the voltage (which determines the amplitude of external magnetic field), can automatically converge from a random initial value to the desired one only after few iterations. We experimentally demonstrate our adaptive Bayesian algorithm and find it is effective and efficient. If the relation between the target frequency and the controlled voltage is linear, similar to the traditional method, our algorithm can automatically search the desired voltage. The robustness of our algorithm against noises coming from observed CPT spectra as well as the fluctuation of controlled voltage is also demonstrated. While in the situation where the relation between the target frequency and the controlled voltage is nonlinear, the converged standard deviation obtained via our algorithm shows a significant improvement compared to the traditional method.

2. Magneto-sensitive coherent population trapping of rubidium atoms

Under the lin$||$lin CPT configuration, the directions of linear polarization of the two CPT frequency components are parallel each other and orthogonal to a tiny static magnetic field [18,20,22]. Figure 1(a) shows the coupled energy levels of $^{87}$Rb atoms. For magneto-insensitive transitions, the bichromatic field simultaneously coupled the atoms via two separate $\Lambda$ systems of $\sigma ^+$ and $\sigma ^-$ transitions connecting the ground state sublevels $|F_g=1, m_F=\pm 1\rangle$ and $|F_g=2, m_F=\mp 1\rangle$ with the excited state $|F_e=1, m_F=0\rangle$, respectively. The first-order Zeeman shifts of the two $\Lambda$ systems have equal strength but with opposite sign. Both $\Lambda$ systems contribute to the central magneto-insensitive resonance (red solid arrows). For magneto-sensitive transitions, the bichromatic field accordingly couples the atoms via a $\Lambda$ system connecting the ground state sublevels $|F_g=1, m_F=-1\rangle$ ($|F_g=1, m_F=1\rangle$) and $|F_g=2, m_F=-1\rangle$ ($|F_g=2, m_F=1\rangle$). Therefore, the CPT resonances yield two microwave magneto-sensitive transitions between $|F_g=1, m_F=\pm 1\rangle$ and $|F_g=2, m_F=\pm 1\rangle$ (dashed arrows).

 figure: Fig. 1.

Fig. 1. Experimental CPT system of laser-cooled $^{87}$Rb atoms. (a) Energy levels of $^{87}\textrm {Rb}$ for lin$||$lin CPT scheme. Two separate $\Lambda$ systems of $\sigma ^+$ and $\sigma ^-$ magneto-insensitive transitions connecting the ground state sublevels $|F_g=1, m_F=\pm 1\rangle$ and $|F_g=2, m_F=\mp 1\rangle$ with the common excited state $|F_e=1, m_F=0\rangle$ (red solid lines), one $\Lambda$ system of $\sigma ^+$ magneto-sensitive transition connecting the ground state sublevels $|F_g=1, m_F=-1\rangle$ and $|F_g=2, m_F=-1\rangle$ (blue dashed lines), and another $\Lambda$ system of $\sigma ^-$ magneto-sensitive transition connecting the ground state sublevels $|F_g=1, m_F=1\rangle$ and $|F_g=2, m_F=1\rangle$ (brown dashed lines). (b) The observed CPT spectra in the presence of external bias magnetic field. The red solid line is the Lorentz fitting of the experimental data (blue circles). (c) Schematic of experimental setup. PBS: polarization beam splitter, EOM: electro-optic phase modulator, PD: photodetector, AOM: acousto-optic modulator, SAS: Saturated absorption spectroscopy, F-P: Fabry-Pérot cavity, GP: Glan prism. The magnetic field is adapted in realtime through a tunable d.c. voltage controlled by the computer implementing the adaptive Bayesian algorithm.

Download Full Size | PDF

We use a five-level model to describe the system and label the five levels as (see Fig. 1(a)): $|1\rangle = |F_g=1, m_F=+1\rangle ,$ $|2\rangle = |F_g=1, m_F=-1\rangle ,$ $|3\rangle = |F_g=2, m_F=+1\rangle ,$ $|4\rangle = |F_g=2, m_F=-1\rangle ,$ and $|5\rangle = |F_e=1, m_F=0\rangle .$ The time-evolution of the system is governed by the Liouville equation for the density matrix [24],

$$\frac{\partial \rho}{\partial t} ={-}\frac{i}{\hbar}\left(H \rho - \rho H^{{\dagger}}\right)+\dot{\rho}_{src},$$
where the Hamiltonian
$$H=\hbar\left( \begin{array}{ccccc} \Delta_1 & 0 & 0 & 0 & \frac{\Omega^b}{2} \\ 0 & \Delta_2 & 0 & 0 & \frac{\Omega^a}{2} \\ 0 & 0 & \Delta_3 & 0 & \frac{\Omega^b}{2} \\ 0 & 0 & 0 & \Delta_4 & \frac{\Omega^a}{2} \\ \frac{\Omega^b}{2} & \frac{\Omega^a}{2} & \frac{\Omega^b}{2} & \frac{\Omega^a}{2} & \delta-\frac{i\Gamma}{2} \end{array} \right),$$
with the parameters $\Delta _1 = \frac {\Delta }{2} + g_1 \mu _B B_z ,$ $\Delta _2 = \frac {\Delta }{2} - g_1 \mu _B B_z,$ $\Delta _3 = -\frac {\Delta }{2} - g_2 \mu _B B_z,$ and $\Delta _4 = -\frac {\Delta }{2} + g_2 \mu _B B_z.$ Here, the damping rates $\Gamma =2\pi \times 6$ MHz, $\Omega ^{a}$ and $\Omega ^{b}$ are the Rabi frequencies, $\Delta =\delta _1-\delta _2$ and $\delta =(\delta _1+\delta _2)/2$ where $\delta _1$ and $\delta _2$ correspond to the single-photon detuning of the two laser fields. $g_1=-0.5017$ and $g_2=0.4997$ are the effective Landé g-factors, $\mu _B$ is the Bohr magneton, and $B_z$ is the magnetic field along the $z$ axis that causes the Zeeman shifts. Under the weak magnetic field $B_z$ involved in the experiment, the Zeeman sublevels are assumed to undergo only the linear Zeeman shifts.

The term $\dot {\rho }_{src}$ accounts for the influx of atoms into the ground states due to the decay from excited state, which is defined as

$$\dot{\rho}_{src}= \left( \begin{array}{ccccc} \frac{\Gamma_1}{2}\rho_{55} & 0 & 0 & 0 & 0 \\ 0 & \frac{\Gamma_1}{2}\rho_{55} & 0 & 0 & 0 \\ 0 & 0 & \frac{\Gamma_2}{2}\rho_{55} & 0 & 0 \\ 0 & 0 & 0 & \frac{\Gamma_2}{2}\rho_{55} & 0 \\ 0 & 0 & 0 & 0 & 0 \end{array} \right),$$
where $\Gamma _1$ and $\Gamma _2$ are the damping rates decaying from the excited states to the ground states $|F_g=1\rangle$ and $|F_g=2\rangle$. Generally, $\Gamma _1+\Gamma _2=\Gamma$. The decay between the ground states are neglected here.

We can solve the time-dependent element $\rho _{ij}(t)$ ($i,j=1,2,3,4,5$) according to Eq. (1). For $^{87}$Rb atom, $\Gamma _1=\Gamma /4$, $\Gamma _2=3\Gamma /4$, and the Rabi frequencies $\Omega _a=\sqrt {3}\Omega _0$, $\Omega _b=\Omega _0$ with $\Omega _0=2$ MHz in our experiment. Initially, the atoms are equally populated in the four ground states $|1\rangle$, $|2\rangle$, $|3\rangle$, and $|4\rangle$. The duration of the CPT pulse is set as $\tau =1$ ms, which is sufficiently long to reach the steady state. $1-\rho _{55}$ characterizes the transmission of light after passing through the atoms. Through calculating the final population in the excited state $\rho _{55}(\tau )$ for different detuning $\Delta$, we can use the normalized amplitude of ($1-\rho _{55}$) to describe the CPT resonances.

Figure 1(c) depicts the schematic of the experimental apparatus. The system consists of a three-dimensional magneto-optical trap (MOT), a CPT laser system and an adaptive controller. The MOT apparatus comprises an ultra-high vacuum cell with pressure of $10^{-8}$ Pa, a quadruple magnetic field produced from a pair of magnetic coils, and laser beams. Typically, the MOT can trap about $10^7$ $^{87}\textrm {Rb}$ atoms within a 100 ms cooling period. The CPT beam is generated by a single laser passing through an electro-optic phase modulator (EOM). The CPT laser source is a diode laser tuned to the $^{87}\textrm {Rb}$ D1 transitions at 795 nm. The laser beam is split into two parts by a half-wave plate and a polarization beam splitter (PBS). One beam is used to offset lock the laser frequency to the transition between $|F_g=2\rangle$ and $|F_e=1\rangle$ with saturated absorption spectroscopy (SAS). The other beam is sent to a fiber-coupled EOM modulated by a microwave at 6.835 GHz. The positive first-order sideband forms the $\Lambda$ systems with the carrier. The output of the EOM is split into two parts by a half-wave plate and a PBS. The reflected beam is sent to a Fabry-Pérot (FP) cavity that monitors the intensity of sidebands generated by the EOM. The powers of the first-order sidebands are set equal to that of the carrier signal via adjusting the power applied to the EOM. Being far detuned from any resonances, the extra sidebands do not contribute to the CPT signal. The transmitted beam is sent to a double-pass acousto-optic modulator (AOM) that shifts the optical frequencies to resonances and switches on or off the CPT beam. Then the beam is coupled into a polarization maintaining fiber. After the fiber, the CPT beam is collimated to an 8-mm-diameter beam and sent through a Glan prism to purify the linear polarization.

After the Glan prism, the available laser power is hundreds of microWatt. Then, the CPT beam is separated equally into two beams by a half-wave plate and a PBS. One beam is sent to the normalization photodetector (PD2) which is used as a normalization signal to reduce the effect of intensity noise on the CPT signals. Another beam is sent to interrogate the cold atoms, and the transmitted light is collected on the other photodetector (PD1). The coherent beam is turned on with 1 ms latency time after turning off the MOT. The transmitted and normalized beams are synchronously measured with corresponding photodetectors (denoted by $S_T$ and $S_N$) during the CPT pulse. Finally, the CPT spectra are obtained from the signal $S_T/S_N$, as shown in Fig. 1(b). In order to eliminate the stray magnetic field, three pairs of Helmholtz coils are used for compensation. To create the bias magnetic field, we employ an additional pair of Helmholtz coils aligned with the direction of the CPT laser beams. By controlling the coils (whose currents are determined by a d.c voltage $U$), the strength of the bias magnetic field can be precisely tuned.

We focus on the magneto-sensitive CPT resonances. Since the spectrum is symmetric with respect to $\Delta =0$, we only consider the magneto-sensitive transition in the negative detuning regime. In Fig. 2, the observed experimental results (blue dots) and the corresponding numerical calculations (red lines) for the magneto-sensitive CPT resonance are shown. The peaks of numerical simulations match well with that of experimental results. In the middle of the peak, the spectrum is in Lorentz lineshape, which can be fitted by a Lorentz function. The location of the center is the target frequency we desire. We denote the desired frequency (corresponding to a certain detuning value) as $f_d$, which we need to achieve in the experiment.

 figure: Fig. 2.

Fig. 2. Experimental results and numerical simulation of the magneto-sensitive CPT resonance. The observed magneto-sensitive CPT spectra (blue open circles) for (a) $U=8.5000$ V, (b) $U=9.7533$ V, (c) $U=7.4523$ V, and (d) $U=9.1804$ V. These spectra are used as the likelihood function for the iteration with adaptive Bayesian algorithm. The solid lines are the numerical simulation obtained from the five-level model.

Download Full Size | PDF

Generally in experiments, the magnetic field amplitude $B_z$ is proportional to the applied voltage $U$, i.e., $B_z \propto U$. In order to find out the desired voltage $U_d$ corresponding to the target frequency $f_d$, we can calculate the normalized transmission spectrum for different $B_z$ and extract the relation $f_d=g(U_d)$ numerically. However, in practice, one should adjust the voltage and measure the corresponding frequency to obtain a relation $f_d=g(U_d)$, and finally determine the applied voltage by the inverse function, i.e., $U_d=g^{-1}(f_d)$. In order to collect sufficient data for fitting the relation $f=g(U)$, a large amount of center frequency $f$ should be experimentally measured at different values of voltage $U$ manually, and the value of $f_d$ should be averaged over a large amount of data to reduce the deviation. Besides, if the relation between the target frequency and the voltage is not linear, this traditional method becomes inconvenient in finding suitable fitting function $g(U)$, as shown in the Sec. 3.

3. Adaptive Bayesian algorithm for searching a desired transition frequency

In this section, we will show how to automatically obtain the suitable experimental parameters for a desired transition via the adaptive Bayesian algorithm. We accomplish this task in virtue of an adaptive controller. The adaptive controller is realized with the help of a computer that includes an adaptive Bayesian algorithm and controls over the experimental parameters via digital I/O devices (NI 6536 and NI 6733). The bias magnetic field strength is set via a voltage controlled current source and the applied voltage $U$ is controlled by the computer. The control system is implemented in both Python and LabVIEW which transfer data via TCP sockets. The LabVIEW program controls the digital I/O devices to obtain the CPT spectra and change the applied voltage value automatically. The Python program operates the adaptive Bayesian algorithm that updates the applied voltage in realtime. The rate of the voltage updates is determined by the time of a CPT spectrum scanning ($5$ s), which is 0.2 Hz in the experiment. The adaptive Bayesian algorithm could automatically find the suitable voltage $U_d$ for generating the bias magnetic field corresponding to the magneto-sensitive CPT transition centered at $f_d$. In the following, we introduce the algorithm procedure and present the experimental demonstration in detail.

3.1 Adaptive Bayesian algorithm

Our adaptive Bayesian algorithm for each iteration includes the following key steps [29,39].

  • Step 1: Input a voltage (the $k$-th voltage is denoted by $U_k$, the initial input voltage $U_0$ is randomly chosen) and sweep the detuning to obtain the magneto-sensitive CPT signal,
    $$L_k(f)=\frac{2A_k}{\pi}\frac{w_k}{4[(f-\epsilon_k)^2+w_k^2]} + B_k,$$
    which is fitted by a Lorentz lineshape function involving four fitting parameters $A_k$, $w_k$, $\epsilon _k$ and $B_k$.
  • Step 2: Normalize $L_k(f)$ as $\tilde {L}_k(f)$, where $\tilde {L}_k(f)$ becomes ranging from 0 to 1, i.e.,
    $$\tilde{L}_k(f)=\frac{L_k(f)-\min{L_k(f)}}{\max{L_k(f)}-\min{L_k(f)}}.$$

    Regard $\tilde {L}_k(f)$ as a probability distribution. If the probability at the target frequency $\tilde {L}_k(f_d)>0.5$, the likelihood function remains the same, i.e., $\tilde {L}_k'(f)=\tilde {L}_k(f)$. If the probability at the target frequency $\tilde {L}_k(f_d)\le 0.5$, the likelihood function becomes $\tilde {L}_k'(f)=1-\tilde {L}_k(f)$.

  • Step 3: Calculate the normalized likelihood probability distribution,
    $$P_k(f)=\frac{\tilde{L}_k'(f)}{\int \tilde{L}_k'(f)\textrm{d}f}.$$

    According to the measured probability distribution $P_k(f)$, obtain the posterior probability distribution,

    $$P_{k}^{Post}(f)=\frac{P_k(f)P_k^{Prior}(f)}{\int P_k(f)P_k^{Prior}(f)\textrm{d}f},$$
    where the $k$-th prior probability distribution is the $(k-1)$-th posterior probability distribution, i.e., $P_{k}^{Prior}(f)=P_{k-1}^{Post}(f)$. Usually, there is no pre-knowledge about the unknown parameter available, the initial uninformative prior is a uniform probability distribution, i.e., $P_1^{Prior}(f)=1/C$ with $C=\int \textrm {d}f$.

  • Step 4: Calculate the mean frequency
    $$\bar{f}_k=\int f P^{Post}_k(f) \textrm{d}f,$$
    and its standard deviation
    $$\Delta {f}_k=\sqrt{\int f^2 P^{Post}_k(f) \textrm{d}f - (\bar{f}_k)^2}.$$
  • Step 5: Adjust the voltage of the next step according to the measured probability distribution $P_{k}$.

The rule for adjusting the voltage at each step is given as

$$U_{k+1} = U_{k} + ({-}1)^{s}\cdot h \cdot \delta U/k,$$
where
$$s=\left\{ \begin{array}{lr} 0, & \textrm{if } P_{k}(f_d-\delta f)-P_{k}(f_d+\delta f)<0\\ 1, & \textrm{if } P_{k}(f_d-\delta f)-P_{k}(f_d+\delta f)>0 \end{array}, \right.$$
$$h=\frac{P_{k}(f_d-\delta f)-P_{k}(f_d+\delta f)}{P_{k}(f_d-\delta f)+P_{k}(f_d+\delta f)-2P_{k}(f_d)},$$
and $\delta U$ is a variation step for the voltage, $\delta f$ is a pre-set frequency deviation from the desired frequency $f_d$.

Here, the voltage for the next iteration is adapted according to the current likelihood. The direction of the variation is determined by $s$ which is related to the two probabilities located oppositely respect to $P_k(f_d)$, and the frequency deviation $\delta f$ can be feasibly chosen. $h$ reflects the competition between the difference $P_{k}(f_d-\delta f)-P_{k}(f_d+\delta f)$ and the gradient $P_{k}(f_d-\delta f)+P_{k}(f_d+\delta f)-2P_{k}(f_d)$. If the mean of the current likelihood is far from $f_d$, $h$ becomes large and vice versa. In practice, $h$ is restricted in a modest range, i.e., $h_{min}\le h\le h_{max}$. The variation step $\delta U/k$ is decreased as $k$, and $\delta U$ can be chosen feasibly in experiment. This rule guarantees the efficiency of our adaptation.

When $k$ is modestly large ($N\geq 10$), the mean frequency $\bar {f}_k$ will converge to the desired frequency $f_d$ with reduced standard deviation $\Delta f_k$. Meanwhile, the converged voltage will be close to the desired condition for achieving the magneto-sensitive transition with frequency $f_d$. Finally, the average of the converged voltage for the last few iteration number can be given as the suggested applied voltage $U_d$.

In Fig. 3, we perform the numerical simulation to see how it works. First, the initial voltage is chosen as $U_0=8.5$ V. The prior for the first iteration $P_1^{Prior}(f)$ is a flat distribution, see the blue line in Fig. 3(a). We obtain the magneto-sensitive CPT signal and normalize it as the likelihood $\tilde {L}_k(f)$. Since $\tilde {L}_k(f_d)>0.5$, the likelihood remains as $\tilde {L}_k'(f)=\tilde {L}_k(f)$. According to Eq. (6), we calculate the normalized likelihood probability distribution $P_1(f)$, see the orange line in Fig. 3(b). Then, according to Eq. (7), we obtain the posterior $P_1^{Post}(f)$ and the posterior becomes the prior for the second iteration. The voltage for the second iteration $U_2$ is determined by $P_1(f)$. Since $P_{1}(f_d-\delta f)<P_{1}(f_d+\delta f)$, the central frequency is on the right side of $f_d$. Thus, $s=0$ and $U_2$ should be increased according to Eq. (10). $h$ controls the variation amplitude. We choose $h_{min}=0.2$ and $h_{max}=2$ to restrict the minimum and maximum variation amplitude for simulation. Similarly, the probability distributions for other iterations can be obtained step by step, see Fig. 3(b)-(f). Here, we choose $\delta U=2$ V, $\delta f=42$ kHz.

 figure: Fig. 3.

Fig. 3. Numerical simulation of probability distributions during the adaptation. (a)-(f) The probability distributions versus the iteration number $N$. The blue, orange and yellow lines denote the prior $P^{Prior}_k(f)$, the normalized likelihood $P_k(f)$ and the posterior $P^{Post}_k(f)$ for the $k$-th iteration, respectively. The dashed lines represent the locations of $f_d-\delta f$, $f_d$, and $f_d+\delta f$. Here, the initial voltage $U_0=8.5$ V, the desired magneto-sensitive transition frequency $f_d=-807.6$ kHz.

Download Full Size | PDF

3.2 Experimental demonstration

Next, we perform the experimental demonstration. Through implementing the adaptive Bayesian algorithm, we can obtain the suggested voltage for a desired magneto-sensitive transition frequency, as shown in Fig. 4.

 figure: Fig. 4.

Fig. 4. Experimental results with adaptive Bayesian algorithm. Above row (a)-(d): The converged frequency versus the iteration number for different target frequency $f_d$ with different initial voltage $U_0$. Here, the orange dashed lines denote the target frequency $f_d$. The errorbars correspond to the standard deviations of the converged frequency. Bottom row (e)-(h): The corresponding variation of the applied voltage versus the iteration number $N$ for the above row. The voltage for the next step is adapted according to the Bayesian algorithm. If the estimated frequency is far away from the target, the variation amplitude of the voltage for the next step will get large, and vice versa. Comparing (a, e) and (b, f) for the same initial voltage, the final voltage will converge to the corresponding value according to the target frequency. Comparing (c, g) and (d, h), despite the adaption of voltage is different, the final stages of the iteration are similar and the suggested voltage is the same for $U_0=6$ V and $U_0=4$ V.

Download Full Size | PDF

Initially, there is no prior knowledge. The mean and standard deviation for $N=1$ are calculated from a CPT spectrum at a random initial voltage. Generally, its standard deviation is large and its mean deviates severely from the target. At this moment, we get a rough information for the target frequency and the applied voltage. Continually, more CPT spectra for different applied voltage are observed in experiment. Based on the earlier outcomes within the measurement sequence, the knowledge of the target frequency on the applied voltage can be gradually acquired.

As the iteration number becomes larger, more CPT spectra close to the target frequency are observed, the mean of the estimated frequency will locate closer and closer to the target frequency, and the voltage tends to be stable (see Fig. 4). Meanwhile, the standard deviation of target frequency can be reduced dramatically after limited number of iteration [see Fig. 5(a)]. Due to involving multiple products among many similar probability distributions, the posterior probability distribution becomes narrower when the iteration number increases, see Fig. 5(b). If the posterior probability after iteration is standardized to ranging from 0 to 1, a narrower CPT spectrum for the desired magneto-sensitive transition will be obtained. The average of the voltage for the last few iteration number $U_d=\sum _{N=K}^{M}U_N/(M-K+1)$ can be used for achieving the desired magneto-sensitive transition at target frequency $f_d$. Here, we choose the last ten iteration number, where $K=41$ and $M=50$.

Our method is simple and straightforward. Before the experiment, one can know little about the relation between the applied voltage and the target frequency. The initial voltage can be chosen randomly. The random choice of initial conditions provides huge feasibility for practical applications, even in other experimental systems. In addition, the standard deviation always dramatically decreases after limited iterations for different trials. Here, our algorithm is verified in the standard case where the relation between the target frequency and the applied voltage is linear.

 figure: Fig. 5.

Fig. 5. Convergence of standard deviation and posterior probability distribution. (a) The standard deviation $\Delta f$ versus the iteration number $N$. The converges for the standard deviation for the estimated frequency appear only after very limited iteration number. For a target frequency $f_d=-807.6$ kHz, starting from a random choice $U_0=8.5$ V, the standard deviation $\Delta f$ dramatically decreases after iteration number $N=5$. When $N=10$, $\Delta f$ becomes stable and gradually converges. (b) The posterior probability distribution for $N=1, 10, 20, 30, 40$ and $50$. Every posterior probability distribution contains the information from previous iterations. The multiple product among many similar probability distributions speeds up the convergence. As the iteration number increases, the posterior probability distribution becomes narrower and its mean value approaches the target frequency (denoted by the black solid line).

Download Full Size | PDF

To demonstrate the robustness of our algorithm, we take into account the noises in two different ways. Firstly, we test the observed CPT spectra which is noisy, see the lower inset of Fig. 6(b) whose signal-to-noise ratio of the CPT spectra is reduced compared to the one of Fig. 6(a). Despite the CPT spectra become noisy, it can still converge to the target frequency and the corresponding standard deviation remains the same level after limited iterations compared to the case with normal CPT spectra as shown in Fig. 6(a). Secondly, we proactively add a small amount of stochastic white noise to each of the applied voltage, i.e., $U_k\rightarrow U_k+U_{\epsilon }$ where $U_{\epsilon }\in [-0.05 V,0.05 V]$ and $\overline {U_{\epsilon }}=0$. As shown in Fig. 6(c), the applied voltage can still converge to the desired one. By contrast, using traditional method that manually extracting the relation $f_d=g(U_d)$ by fitting [see the inset of Fig. 6(c)], the standard deviation (the red errorbar) is about 6.2 kHz, which is nearly 6 times larger than the one obtained via our algorithm. The experimental results show that our algorithm is more robust against different noises.

 figure: Fig. 6.

Fig. 6. Experimental results via adaptive Bayesian algorithm under different scenarios. (a) Results obtained via normal magneto-sensitive CPT spectra. (b) Results obtained via noisy magneto-sensitive CPT spectra. (c) Results obtained via stochastic white noise of applied voltage. The linear relation between target frequency and applied voltage is shown in the inset. The circle is the experimental data while the red line is the linear fitting. (d) Results obtained in the situation where the relation between the target frequency and the applied voltage is nonlinear. The circle is the experimental data while the red line is the quadratic fitting. The red errorbars correspond to the standard deviations using traditional method extracted by fitting the relation $f_d=g(U_d)$ with the same number of measurement trials. The orange dashed lines denote the target frequency $f_d=-607.6$ kHz.

Download Full Size | PDF

Furthermore, the advantage of our adaptive Bayesian algorithm becomes significant when the relation between the target frequency and the applied voltage becomes nonlinear. To test its validity, we consider the situation where the target frequency $f_d$ is a quadratic function of the applied voltage $U_d$, i.e. $f \propto U^2$. To get this relation, we set the voltage-controlled current as a quadratic function of $U_d$ via LabVIEW program. As shown in inset of Fig. 6(d), by manually varying the applied voltage and obtained the corresponding CPT spectra, one can roughly extract the relation $f_d=g(U_d)$ by fitting. The obtained standard deviation is about 16.3 kHz (the red errorbar). Instead, by using our algorithm, although the speed of convergence is not fast as the case of linear relation (when $N=9$, the standard deviation of the quadratic relation is 64 kHz while the one of linear relation reaches 4 kHz), the standard deviation can still dramatically decrease after $N=10$ [Fig. 6(d)]. The corresponding standard deviation for $N=50$ reaches 1.1 kHz, which is about 15 times smaller than the one of traditional method. Our algorithm shows effectiveness and efficiency in dealing with the complicated cases where the relation between the target frequency and the controlled parameter is not linear.

4. Conclusions and discussions

We have experimentally demonstrated how to automatically search a desired magneto-sensitive transition by an adaptive Bayesian algorithm. Our algorithm is based on the Bayes’ theorem that the main features can be inferred effectively through updating the probability distribution after each measurement. The adaptivity can effectively search the desired magneto-sensitive transition condition from a random initial voltage only after few iterations. In particular, if the relation between the target frequency and the controlled parameter is quadratic, our algorithm can be much more effective and efficient than the traditional methods. Our adaptive Bayesian algorithm can be applied in many practical scenarios.

Firstly, this simple and efficient method for determining a desired transition frequency can be widely applied to precision frequency measurement such as developing practical CPT-based clocks [4548]. On one hand, the narrower posterior probability can improve spectral resolution. On the other hand, our adaptive Bayesian algorithm can optimize the experimental conditions to reduce the systemic shifts, such as searching the zero magnetic field point.

Secondly, exchanging the roles of the transition frequency and the magnetic field, our CPT experiment with adaptive Bayesian algorithm can be inversely designed to probe an unknown static magnetic field $B_s$. For the magneto-sensitive transition we used, the target frequency $f_d=-2 \gamma B_z$ with $\gamma$ the gyromagnetic ratio of $^{87}$Rb atom [49]. By implementing our adaptive Bayesian algorithm, the measured magnetic field $B_z=-f_d/(2\gamma )$ is the sum of the unknown static magnetic field $B_s$ and the applied magnetic field $B_d$. Since $B_d$ is proportional to $U_d$, the unknown static magnetic field can be deduced by the relation $B_s=-f_d/(2\gamma )-B_d$.

Thirdly, the adaptive Bayesian algorithm can be widely extended to various physical systems where some certain controllable parameters can be introduced for adaptation. Our algorithm may be improved to the cases of multiple controlled parameters. The adaptation of controllable parameters can be modified according to the idea of gradient descent and so that the Bayesian method can further speed up the iteration procedure. For more complicated cases, the experiment-design heuristics for the adaption can also be efficiently obtained via neural-network techniques [17].

Funding

Key-Area Research and Development Program of Guangdong Province (2019B030330001); National Natural Science Foundation of China (11874434, 12025509); Science and Technology Program of Guangzhou (201804010497, 201904020024, 202002030459); Natural Science Foundation of Guangdong Province (2018A030313988).

Disclosures

The authors declare that they have no conflict of interest.

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

References

1. C. L. Degen, F. Reinhard, and P. Cappellaro, “Quantum sensing,” Rev. Mod. Phys. 89(3), 035002 (2017). [CrossRef]  

2. P. Mehta, M. Bukov, C.-H. Wang, A. G. R. Day, C. Richardson, C. K. Fisher, and D. J. Schwab, “A high-bias, low-variance introduction to machine learning for physicists,” Phys. Rep. 810, 1–124 (2019). [CrossRef]  

3. L. J. Fiderer, J. Schuff, and D. Braun, “Neural-network heuristics for adaptive Bayesian quantum estimation,” PRX Quantum 2(2), 020303 (2021). [CrossRef]  

4. Y. Li, L. Pezzè, M. Gessner, Z. Ren, W. Li, and A. Smerzi, “Frequentist and Bayesian quantum phase estimation,” Entropy 20(9), 628 (2018). [CrossRef]  

5. K. Macieszczak, M. Fraas, and R. Demkowicz-Dobrzański, “Bayesian quantum frequency estimation in presence of collective dephasing,” New J. Phys. 16(11), 113002 (2014). [CrossRef]  

6. P. Palittapongarnpim and B. C. Sanders, “Robustness of quantum-enhanced adaptive phase estimation,” Phys. Rev. A 100(1), 012106 (2019). [CrossRef]  

7. T. Ruster, H. Kaufmann, M. A. Luda, V. Kaushal, C. T. Schmiegelow, F. Schmidt-Kaler, and U. G. Poschinger, “Entanglement-based dc magnetometry with separated ions,” Phys. Rev. X 7(3), 031050 (2017). [CrossRef]  

8. R. Kaubruegger, D. V. Vasilyev, M. Schulte, K. Hammerer, and P. Zoller, “Quantum variational optimization of Ramsey interferometry and atomic clocks,” arXiv:2102.05593.

9. F. E. Becerra, J. Fan, G. Baumgartner, J. Goldhar, J. T. Kosloski, and A. Migdall, “Experimental demonstration of a receiver beating the standard quantum limit for multiple nonorthogonal state discrimination,” Nat. Photonics 7(2), 147–152 (2013). [CrossRef]  

10. R. Blume-Kohout, “Optimal, reliable estimation of quantum states,” New J. Phys. 12(4), 043034 (2010). [CrossRef]  

11. M. P. V. Stenberg, Y. R. Sanders, and F. K. Wilhelm, “Efficient estimation of resonant coupling between quantum systems,” Phys. Rev. Lett. 113(21), 210404 (2014). [CrossRef]  

12. C. Granade, J. Combes, and D. G. Cory, “Practical Bayesian tomography,” New J. Phys. 18(3), 033024 (2016). [CrossRef]  

13. J. Wang, S. Paesani, R. Santagati, S. Knauer, A. A. Gentile, N. Wiebe, M. Petruzzella, J. L. O’Brien, J. G. Rarity, A. Laing, and M. G. Thompson, “Experimental quantum Hamiltonian learning,” Nat. Phys. 13(6), 551–555 (2017). [CrossRef]  

14. C. E. Granade, C. Ferrie, N. Wiebe, and D. G. Cory, “Robust online Hamiltonian learning,” New J. Phys. 14(10), 103013 (2012). [CrossRef]  

15. G. Wang, D. E. Koh, P. D. Johnson, and Y. Cao, “Minimizing estimation runtime on noisy quantum computers,” PRX Quantum 2(1), 010346 (2021). [CrossRef]  

16. J. P. Dowling and G. J. Milburn, “Quantum technology: the second quantum revolution,” Phil. Trans. R. Soc. A 361(1809), 1655–1674 (2003). [CrossRef]  

17. R. Puebla, Y. Ban, J. F. Haase, M. B. Plenio, M. Paternostro, and J. Casanova, “Versatile atomic magnetometry assisted by Bayesian inference,” arXiv:2003.02151.

18. S. A. Zibrov, I. Novikova, D. F. Phillips, R. L. Walsworth, A. S. Zibrov, V. L. Velichansky, A. V. Taichenachev, and V. I. Yudin, “Coherent-population-trapping resonances with linearly polarized light for all-optical miniature atomic clocks,” Phys. Rev. A 81(1), 013833 (2010). [CrossRef]  

19. F.-X. Esnault, E. Blanshan, E. N. Ivanov, R. E. Scholten, J. Kitching, and E. A. Donley, “Cold-atom double-Λ coherent population trapping clock,” Phys. Rev. A 88(4), 042120 (2013). [CrossRef]  

20. X. Liu, E. N. Ivanov, V. I. Yudin, J. Kitching, and E. A. Donley, “Low-drift coherent population trapping clock based on laser-cooled atoms and high-coherence excitation fields,” Phys. Rev. Appl. 8(5), 054001 (2017). [CrossRef]  

21. E. Breschi, G. Kazakov, R. Lammegger, G. Mileti, B. Matisov, and L. Windholz, “Quantitative study of the destructive quantum-interference effect on coherent population trapping,” Phys. Rev. A 79(6), 063837 (2009). [CrossRef]  

22. E. E. Mikhailov, T. Horrom, N. Belcher, and I. Novikova, “Performance of a prototype atomic clock based on lin║lin coherent population trapping resonances in Rb atomic vapor,” J. Opt. Soc. Am. B 27(3), 417–422 (2010). [CrossRef]  

23. M. A. Hafiz, G. Coget, P. Yun, S. Guéerande, E. de Clercq, and R. Boudot, “A high-performance Raman-Ramsey Cs vapor cell atomic clock,” J. Appl. Phys. 121(10), 104903 (2017). [CrossRef]  

24. M. S. Shahriar, Y. Wang, S. Krishnamurthy, Y. Tu, G. S. Pati, and S. Tseng, “Evolution of an N-level system via automated vectorization of the Liouville equations and application to optically controlled polarization rotation,” J. Mod. Opt. 61(4), 351–367 (2014). [CrossRef]  

25. S. D. Sarma, D.-L Deng, and L.-M Duan, “Machine learning meets quantum physics,” Phys. Today 72(3), 48–54 (2019). [CrossRef]  

26. T. Fösel, P. Tighineanu, T. Weiss, and F. Marquardt, “Reinforcement learning with neural networks for quantum feedback,” Phys. Rev. X 8(3), 031084 (2018). [CrossRef]  

27. N. Friis, D. Orsucci, M. Skotiniotis, P. Sekatski, V. Dunjko, H. J. Briegel, and W. Dür, “Flexible resources for quantum metrology,” New J. Phys. 19(6), 063044 (2017). [CrossRef]  

28. J. Rubio and J. Dunningham, “Bayesian multiparameter quantum metrology with limited data,” Phys. Rev. A 101(3), 032114 (2020). [CrossRef]  

29. A. Lumino, E. Polino, A. S. Rab, G. Milani, N. Spagnolo, N. Wiebe, and F. Sciarrino, “Experimental phase estimation enhanced by machine learning,” Phys. Rev. Appl. 10(4), 044033 (2018). [CrossRef]  

30. M. Valeri, E. Polino, D. Poderini, I. Gianani, G. Corrielli, A. Crespi, R. Osellame, N. Spagnolo, and F. Sciarrino, “Experimental adaptive Bayesian estimation of multiple phases with limited data,” npj Quantum Inf. 6(1), 92 (2020). [CrossRef]  

31. H. M. Wiseman, “Adaptive phase measurements of optical modes: going beyond the marginal Q distribution,” Phys. Rev. Lett. 75(25), 4587–4590 (1995). [CrossRef]  

32. D. W. Berry and H. M. Wiseman, “Optimal states and almost optimal adaptive measurements for quantum interferometry,” Phys. Rev. Lett. 85(24), 5098–5101 (2000). [CrossRef]  

33. B. L. Higgins, D. W. Berry, S. D. Bartlett, H. M. Wiseman, and G. J. Pryde, “Entanglement-free Heisenberg-limited phase estimation,” Nature 450(7168), 393–396 (2007). [CrossRef]  

34. M. A. Armen, J. K. Au, J. K. Stockton, A. C. Doherty, and H. Mabuchi, “Adaptive homodyne measurement of optical phase,” Phys. Rev. Lett. 89(13), 133602 (2002). [CrossRef]  

35. T. A. Wheatley, D. W. Berry, H. Yonezawa, D. Nakane, H. Arao, D. T. Pope, T. C. Ralph, H. M. Wiseman, A. Furusawa, and E. H. Huntington, “Adaptive optical phase estimation using time-symmetric quantum smoothing,” Phys. Rev. Lett. 104(9), 093601 (2010). [CrossRef]  

36. A. Hentschel and B. C. Sanders, “Machine learning for precise quantum measurement,” Phys. Rev. Lett. 104(6), 063603 (2010). [CrossRef]  

37. S. Daryanoosh, S. Slussarenko, D. W. Berry, H. M. Wiseman, and G. J. Pryde, “Experimental optical phase measurement approaching the exact Heisenberg limit,” Nat. Commun. 9(1), 4606 (2018). [CrossRef]  

38. C. Bonato and D. W. Berry, “Adaptive tracking of a time-varying field with a quantum sensor,” Phys. Rev. A 95(5), 052348 (2017). [CrossRef]  

39. N. M. Nusran and M. V. G. Dutt, “Optimizing phase-estimation algorithms for diamond spin magnetometry,” Phys. Rev. B 90(2), 024422 (2014). [CrossRef]  

40. W. von der Linden, V. Dose, and U. von Toussaint, Bayesian probability theory, (Cambridge University Press, 2014).

41. M. Jarzyna and R. Demkowicz-Dobrzański, “True precision limits in quantum metrology,” New J. Phys. 17(1), 013010 (2015). [CrossRef]  

42. N. Wiebe and C. Granade, “Efficient Bayesian phase estimation,” Phys. Rev. Lett. 117(1), 010503 (2016). [CrossRef]  

43. H. T. Dinani, D. W. Berry, R. Gonzalez, J. R. Maze, and C. Bonato, “Bayesian estimation for quantum sensing in the absence of single-shot detection,” Phys. Rev. B 99(12), 125413 (2019). [CrossRef]  

44. S. Paesani, A. A. Gentile, R. Santagati, J. Wang, N. Wiebe, D. P. Tew, J. L. O’Brien, and M. G. Thompson, “Experimental Bayesian quantum phase estimation on a silicon photonic chip,” Phys. Rev. Lett. 118(10), 100503 (2017). [CrossRef]  

45. N. F. Ramsey, “A molecular beam resonance method with separated oscillating fields,” Phys. Rev. 78(6), 695–699 (1950). [CrossRef]  

46. A. D. Ludlow, M. M. Boyd, J. Ye, E. Peik, and P. O. Schmidt, “Optical atomic clocks,” Rev. Mod. Phys. 87(2), 637–701 (2015). [CrossRef]  

47. C. Sanner, N. Huntemann, R. Lange, C. Tamm, and E. Peik, “Autobalanced Ramsey spectroscopy,” Phys. Rev. Lett. 120(5), 053602 (2018). [CrossRef]  

48. M. Shuker, J. W. Pollock, R. Boudot, V. I. Yudin, A. V. Taichenachev, J. Kitching, and E. A. Donley, “Ramsey spectroscopy with displaced frequency jumps,” Phys. Rev. Lett. 122(11), 113601 (2019). [CrossRef]  

49. P. D. D. Schwindt, S. Knappe, V. Shah, L. Hollberg, J. Kitching, L. -A. Liew, and J. Moreland, “Chip-scale atomic magnetometer,” Appl. Phys. Lett. 85(26), 6409–6411 (2004). [CrossRef]  

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (6)

Fig. 1.
Fig. 1. Experimental CPT system of laser-cooled $^{87}$Rb atoms. (a) Energy levels of $^{87}\textrm {Rb}$ for lin$||$lin CPT scheme. Two separate $\Lambda$ systems of $\sigma ^+$ and $\sigma ^-$ magneto-insensitive transitions connecting the ground state sublevels $|F_g=1, m_F=\pm 1\rangle$ and $|F_g=2, m_F=\mp 1\rangle$ with the common excited state $|F_e=1, m_F=0\rangle$ (red solid lines), one $\Lambda$ system of $\sigma ^+$ magneto-sensitive transition connecting the ground state sublevels $|F_g=1, m_F=-1\rangle$ and $|F_g=2, m_F=-1\rangle$ (blue dashed lines), and another $\Lambda$ system of $\sigma ^-$ magneto-sensitive transition connecting the ground state sublevels $|F_g=1, m_F=1\rangle$ and $|F_g=2, m_F=1\rangle$ (brown dashed lines). (b) The observed CPT spectra in the presence of external bias magnetic field. The red solid line is the Lorentz fitting of the experimental data (blue circles). (c) Schematic of experimental setup. PBS: polarization beam splitter, EOM: electro-optic phase modulator, PD: photodetector, AOM: acousto-optic modulator, SAS: Saturated absorption spectroscopy, F-P: Fabry-Pérot cavity, GP: Glan prism. The magnetic field is adapted in realtime through a tunable d.c. voltage controlled by the computer implementing the adaptive Bayesian algorithm.
Fig. 2.
Fig. 2. Experimental results and numerical simulation of the magneto-sensitive CPT resonance. The observed magneto-sensitive CPT spectra (blue open circles) for (a) $U=8.5000$ V, (b) $U=9.7533$ V, (c) $U=7.4523$ V, and (d) $U=9.1804$ V. These spectra are used as the likelihood function for the iteration with adaptive Bayesian algorithm. The solid lines are the numerical simulation obtained from the five-level model.
Fig. 3.
Fig. 3. Numerical simulation of probability distributions during the adaptation. (a)-(f) The probability distributions versus the iteration number $N$. The blue, orange and yellow lines denote the prior $P^{Prior}_k(f)$, the normalized likelihood $P_k(f)$ and the posterior $P^{Post}_k(f)$ for the $k$-th iteration, respectively. The dashed lines represent the locations of $f_d-\delta f$, $f_d$, and $f_d+\delta f$. Here, the initial voltage $U_0=8.5$ V, the desired magneto-sensitive transition frequency $f_d=-807.6$ kHz.
Fig. 4.
Fig. 4. Experimental results with adaptive Bayesian algorithm. Above row (a)-(d): The converged frequency versus the iteration number for different target frequency $f_d$ with different initial voltage $U_0$. Here, the orange dashed lines denote the target frequency $f_d$. The errorbars correspond to the standard deviations of the converged frequency. Bottom row (e)-(h): The corresponding variation of the applied voltage versus the iteration number $N$ for the above row. The voltage for the next step is adapted according to the Bayesian algorithm. If the estimated frequency is far away from the target, the variation amplitude of the voltage for the next step will get large, and vice versa. Comparing (a, e) and (b, f) for the same initial voltage, the final voltage will converge to the corresponding value according to the target frequency. Comparing (c, g) and (d, h), despite the adaption of voltage is different, the final stages of the iteration are similar and the suggested voltage is the same for $U_0=6$ V and $U_0=4$ V.
Fig. 5.
Fig. 5. Convergence of standard deviation and posterior probability distribution. (a) The standard deviation $\Delta f$ versus the iteration number $N$. The converges for the standard deviation for the estimated frequency appear only after very limited iteration number. For a target frequency $f_d=-807.6$ kHz, starting from a random choice $U_0=8.5$ V, the standard deviation $\Delta f$ dramatically decreases after iteration number $N=5$. When $N=10$, $\Delta f$ becomes stable and gradually converges. (b) The posterior probability distribution for $N=1, 10, 20, 30, 40$ and $50$. Every posterior probability distribution contains the information from previous iterations. The multiple product among many similar probability distributions speeds up the convergence. As the iteration number increases, the posterior probability distribution becomes narrower and its mean value approaches the target frequency (denoted by the black solid line).
Fig. 6.
Fig. 6. Experimental results via adaptive Bayesian algorithm under different scenarios. (a) Results obtained via normal magneto-sensitive CPT spectra. (b) Results obtained via noisy magneto-sensitive CPT spectra. (c) Results obtained via stochastic white noise of applied voltage. The linear relation between target frequency and applied voltage is shown in the inset. The circle is the experimental data while the red line is the linear fitting. (d) Results obtained in the situation where the relation between the target frequency and the applied voltage is nonlinear. The circle is the experimental data while the red line is the quadratic fitting. The red errorbars correspond to the standard deviations using traditional method extracted by fitting the relation $f_d=g(U_d)$ with the same number of measurement trials. The orange dashed lines denote the target frequency $f_d=-607.6$ kHz.

Equations (12)

Equations on this page are rendered with MathJax. Learn more.

ρ t = i ( H ρ ρ H ) + ρ ˙ s r c ,
H = ( Δ 1 0 0 0 Ω b 2 0 Δ 2 0 0 Ω a 2 0 0 Δ 3 0 Ω b 2 0 0 0 Δ 4 Ω a 2 Ω b 2 Ω a 2 Ω b 2 Ω a 2 δ i Γ 2 ) ,
ρ ˙ s r c = ( Γ 1 2 ρ 55 0 0 0 0 0 Γ 1 2 ρ 55 0 0 0 0 0 Γ 2 2 ρ 55 0 0 0 0 0 Γ 2 2 ρ 55 0 0 0 0 0 0 ) ,
L k ( f ) = 2 A k π w k 4 [ ( f ϵ k ) 2 + w k 2 ] + B k ,
L ~ k ( f ) = L k ( f ) min L k ( f ) max L k ( f ) min L k ( f ) .
P k ( f ) = L ~ k ( f ) L ~ k ( f ) d f .
P k P o s t ( f ) = P k ( f ) P k P r i o r ( f ) P k ( f ) P k P r i o r ( f ) d f ,
f ¯ k = f P k P o s t ( f ) d f ,
Δ f k = f 2 P k P o s t ( f ) d f ( f ¯ k ) 2 .
U k + 1 = U k + ( 1 ) s h δ U / k ,
s = { 0 , if  P k ( f d δ f ) P k ( f d + δ f ) < 0 1 , if  P k ( f d δ f ) P k ( f d + δ f ) > 0 ,
h = P k ( f d δ f ) P k ( f d + δ f ) P k ( f d δ f ) + P k ( f d + δ f ) 2 P k ( f d ) ,
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.