Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Enhancing SPDC brightness using elliptical pump shapes

Open Access Open Access

Abstract

We report on the use of elliptical pump spatial modes to increase the observed brightness of spontaneous parametric downconversion in critically phase-matched crystals. Simulations qualitatively predict this improvement, which depends on the eccentricity and orientation of the pump ellipse. We experimentally confirm a factor of two improvement in brightness when compared to the traditional circular-symmetric pump spatial modes. These results support previous theoretical work that proposes the use of elliptical pump modes to enhance the performance of parametric processes in anisotropic materials.

© 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

1. Introduction

Entangled photon pair sources play a crucial role in fundamental tests of nature [1,2] and emerging quantum applications [3,4]. Spontaneous parametric downconversion [5] (SPDC) is the most common method to generate these photon pairs, with a variety of designs [68] and materials used. In SPDC, a photon (pump, $p$) in a nonlinear crystal can downconvert into two photons (signal, $s$; idler, $i$) obeying energy and momentum conservation.

Early studies identified the influence of pump parameters on parametric brightness [9]. The most comprehensive review on pump optimization was made by Boyd and Kleinman [10], who suggested the use of circular symmetric spatial modes for pumping nonlinear processes. Though used most often, assumptions about circular (isotropic) symmetry might not optimize frequency conversion given that the vast majority of parametric processes take place in anisotropic materials. A specific case of interest, where the anisotropy is important, is when using critical phase matching in birefringent materials. When the pump is extraordinarily polarized it experiences spatial walk-off, as depicted in Fig. 1(a). The interplay of pump spatial modes with walk-off was first studied by Volosov [11] and Kuizenga [12]. They showed that elliptical pump shapes could improve frequency conversion performance in second-harmonic generation (SHG) and other parametric processes. Their main observation was that the spatial walk-off limits the overlap of any parametric emission (see Fig. 1(b)). This restricts the benefits of tight pump focusing in the direction of walk-off. In contrast, this restriction is absent in the non-walk-off direction, which allows for tighter focusing. Hence, it is natural to consider different focusing conditions for different directions, leading to an elliptical (astigmatic) spatial mode.

 figure: Fig. 1.

Fig. 1. (a) Side view of the pump spatial walk-off (blue line) within the crystal. The collinear SPDC emission is depicted by red arrows. The dotted line is the crystal’s optical axis. (b) Sketch adapted from [12] representing the overlap between the pump beam (solid lines) and the downconversion beams (dotted lines), depicting the importance of controlling the pump focusing in order to maximize the overlap. (c) Collinear SPDC emission profile at the exit face of the crystal when the major axis of the pump ellipse (inset) is parallel to the walk-off direction. (d) Same as (c) but the ellipse major axis is rotated by 90$^\circ$. (e) Experimental setup, 1: single-mode fiber pump output, 2: collimation lens (focal length: 4.02 mm), 3: cylindrical lens 1 (CL1), 4: cylindrical lens 2 (CL2), 5: focusing lens (FL), 6: BBO crystal, 7-8: dichroic mirror and long-pass filter, respectively, to remove excess pump light, 9: achromatic collection lens; 10: single-mode fiber, 11: photon separation via a dichroic mirror followed by coincidence detection setup.

Download Full Size | PDF

Experimental studies on SHG using elliptical pump beams verified the predicted gain, but the general observation was that the additional experimental complexity involving cylindrical focusing appeared to offset any enhancement [13,14]. This observation stems from the challenges of operating elliptical beams in a resonant cavity. However, single-pass parametric processes such as SPDC are exempt from these difficulties.

In this work, we study the effect of combining elliptical pump and circular-symmetric collection modes in type-I SPDC with negative birefringent materials. Our approach is outlined in Fig. 1. We distinguish between two pump orientations; parallel (Fig. 1(c)) and orthogonal (Fig. 1(d)) to the walk-off plane (defined by the propagation and walk-off direction).

To systematically investigate the effect of pump eccentricity, a continuous-wave, holographic-grating laser diode (with spectral linewidth $\Delta \nu$=160 MHz) is launched from a single-mode fiber (3 µm core size, 0.1 numerical aperture) before undergoing cylindrical focusing. The eccentricity of the pump is defined via the aspect ratio $r=\frac {\omega _y}{\omega _x}$, where $\omega _y$ ($\omega _x$) is the vertical (horizontal) waist of the ellipse. In our discussion, the vertical direction is associated with the walk-off. The change in pump aspect ratio was achieved by tuning only the waist of the horizontal axis. For the ideal pump shape, Kuizenga suggests that the size of the pump in the two directions are determined separately by considering whether walk-off is present [12].

To optimize the pump shape in each direction, we should utilize the birefringence parameter $B$ [10]:

$$B=\frac{\rho}{2}(lk_{0})^{1/2},$$
where $\rho$ is the walk-off angle, $l$ is the length of the crystal and $k_0$ is the pump wave vector. In the direction where there is no walk-off, $B=0$. Knowing the $B$ parameter, the optimal $\xi$ value (the ratio between crystal length $l$ and the confocal parameter $b$) can be inferred via the optimization curves shown in Fig. 2. The physical meaning of $\xi$ relates to the fact that longer crystals need larger focus sizes in order to mitigate the decrease in beam overlap due to spatial walk-off. The figure of merit $h_m(B,\xi )$, which assumes perfect phase-matching, is defined as $h_m(B,\xi )=h_m(\sigma ,\beta ,\xi )=\left (\frac {\pi ^{2}}{2}\right )| H(\sigma ,\beta ,\xi )|^{2}$, with $| H(\sigma ,\beta ,\xi )|^{2}=(2\pi )^{-1}\int _{-\xi }^{+\xi } \frac {\exp (i\sigma \tau -(\beta ^{2}\tau ^{2})}{1+i\tau }\mathrm {d}{\tau }$; where $\sigma =\frac {1}{2}b\Delta k$ ($\Delta k$ is the SPDC phase mismatch), $\beta =B\xi ^{-\frac {1}{2}}$ and $\tau$ is a variable that determines the position of the beam focus within the crystal.

 figure: Fig. 2.

Fig. 2. Optimization curves for circular symmetric beams reported in [10]. For different walk-off parameter $B$ (shown above each curve), $\xi$ (ratio between crystal length and the confocal parameter $b$, x-axis) and the figure of merit $h_m(B,\xi )$. Resorting to the appropriate curve and knowing the walk-off angle and the length of the crystal, the optimal circular symmetric beam for a particular wavelength $\lambda _0$ can be determined.

Download Full Size | PDF

The experimental layout for investigating elliptical pump performance is shown in Fig. 1(e). A 5 mm $\beta$-Barium Borate (BBO) crystal (cut-angle $\theta = 28.76^\circ$) is pumped with 405 nm light to generate type-I, collinear, non-degenerate SPDC wavelengths (signal and idler wavelengths at 776 nm and 847 nm, respectively). Excess pump power was removed by a dichroic mirror and a long-pass filter. Finally, the SPDC photons were coupled into a single-mode fiber and sent to a detection setup.

A range of pump aspect ratios were realized with different cylindrical lenses. Once a target aspect ratio was achieved, a plano-convex lens focused down the pump ellipse (see Tables 1 and 2).

According to the literature [10], the optimal pump waist in the walk-off direction (given our crystal properties: $\rho = {3.83}^{\circ}$, $l= {5}\;{\textrm{mm}}$ and $\lambda _0 = {405}\;{\textrm{nm}}$) is 22 µm, whereas the optimal pump waist in the direction with no walk-off is 7.5 µm. This gives the optimal aspect ratio of $r=2.9$.

These optimal values, however, do not take into account experimental limitations, such as aberrations introduced by thick lenses. Empirically, we found that in our setup a pump waist of 93 µm optimized the brightness and collection efficiency when the aspect ratio was 1.0, with a collection waist of 38 µm.

Therefore, to investigate the effect of the pump aspect ratio we fixed the pump size in the walk-off direction at 93 µm. Correspondingly, the pump size in the non-walk off direction ranged from 21 µm to 141 µm. Thus, the range of aspect ratios that were implemented ranged from 4.44 to 0.66. The experiment was then repeated for the case where the major axis of the pump beam was orthogonal to the walk-off direction. In this case, the experimental aspect ratio investigated ranged from 2.94 to 0.65.

2. Model

To provide better insight on the interplay of elliptical pump and circular collection modes a model was developed. Within the model, the SPDC intensity is governed by the conventional phase matching conditions of the respective ($p$, $s$ and $i$) fields. The classical $p$ field is treated as a probability distribution of $\vec {k}_p$, that follows the angular and spatial intensity distributions of a Gaussian beam profile. At the start of the simulation we thus randomly choose a set of wavelength $\lambda _p$, starting position $\{x,y,z\}$ and propagation direction $\vec {k}_{p}$ from their respective distributions. The individual treatment for each $\vec {k}_p$ allows us to account for effects such as the wavefront curvature of the pump field and spatial distribution of the pump intensity.

From this starting point, we randomly generate a signal and idler pair, $\vec {k}_{s}$ and $\vec {k}_{i}$, according to the weighting function $A$:

$$A= e^{-\frac{( \omega_{x} \Delta k_{x} )^{2}+( \omega_{y} \Delta k_{y})^{2}}{2}} \cdot {\textrm{sinc}} \left(\frac{l\Delta k_{z}}{2}\right)^{2} .$$
Here, $\Delta \vec {k} = \Delta k_x\hat {x} + \Delta k_y \hat {y} + \Delta k_z \hat {z}$ is the phase mismatch in Cartesian coordinates, $\omega _{x,y}$ the beam waist in horizontal (x) and vertical (y) directions, and $l$ the crystal length. This weighting takes into account the phase mismatch in the $\hat {z}$ direction that is relevant on the scale of the length of the crystal $l$, while the mismatch in the $\hat {x}$ and $\hat {y}$ directions is relevant only on the scale of pump waist. This function ensures the generation of a signal/idler pair with wavelengths $\lambda _{s}$ and $\lambda _{i}$ and propagation directions $\vec {k}_{s}$ and $\vec {k}_{i}$ according to the phase-matching conditions present in the crystal.

Using conventional ray-tracing techniques, the $\vec {k}_{s},\vec {k}_{i}$ pair is propagated through the downstream optics towards a single-mode fiber (numerical aperture of $0.1$, core diameter 5 µm). The position and angle of incidence of the rays at the face of the collection fibre determines whether or not the rays are collected. By repeating this processes (sample size: 5×106 rays), an overall coupling efficiency can be determined. The model is available online at: https://github.com/arianstolk/SPDC_test/.

3. Results and discussion

The simulated and experimental results are shown in Figs. 3(a)–3(c) and Figs. 4(a)–4(c), respectively. When the major axis of the pump ellipse is parallel to the walk-off direction, the experimental brightness (or coincidence count rate) agrees qualitatively with the model, which predicts increased brightness for larger pump aspect ratio. The best observed improvement over the circular symmetric mode is a factor of 2. When the major axis of the pump ellipse is orthogonal to the walk-off direction, there is a dramatic difference as the brightness shows little response when the aspect ratio changes.

 figure: Fig. 3.

Fig. 3. Results for the regime where the major axis of the pump ellipse is parallel to the walk-off direction. (a) Simulated in-fiber brightness at different collection beam waists for different pump aspect ratios. The shaded area indicates 1 s.d. confidence interval assuming Poisson statistics. (b) CCD camera images of the pump at the crystal position. (c) Experimentally observed brightness at different collection beam waists for different pump aspect ratios.

Download Full Size | PDF

 figure: Fig. 4.

Fig. 4. Results for the regime where the major axis of the pump ellipse is orthogonal to the walk-off direction. (a) Simulated in-fiber brightness at different collection beam waists for different pump aspect ratios. Here, the ellipse is rotated 90° with respect to the data presented in Fig. 3. The shaded area indicates 1 s.d. confidence interval assuming Poisson statistics. (b) CCD camera images of the pump at the crystal position. (c) Experimental in-fiber brightness at different collection beam waists for different pump aspect ratios.

Download Full Size | PDF

In the case where the major axis is aligned with the walk-off direction, increasing the aspect ratio monotonically increased the photon pair brightness that can be observed. Due to experimental difficulties, the optimal aspect ratio of 2.9 was not achieved. However, it is instructive to consider the results of the two aspect ratios that bracket this value. These results showed a strong dependence of brightness on the orientation of the pump major axis, validating Kuizenga’s proposal.

In Fig. 3(c), there is a strong linear relationship between the brightness and collection waist, which is not present in the model. This is attributed partly to the lack of precision within the model which uses the thin lens approximation for modeling the single-mode fiber photon collection and ignores the lens thickness. Furthermore, the observed $M^{2}$ value of the pump beam in the walk-off direction deviates from the ideal case for large aspect ratio due to lens aberrations when using thick cylindrical lenses (see Table 3 for detailed pump beam parameters).

Tables Icon

Table 1. Focal length of the lenses utilized to implement different aspect ratios in the data presented in Fig. 3(c). CL: cylindrical lens, FL: focusing lens.

Tables Icon

Table 2. Focal length of the lenses utilized to implement different aspect ratios in the data presented in Fig. 4(c). CL: cylindrical lens, FL: focusing lens.

Tables Icon

Table 3. The Rayleigh length is defined as $z_R = \frac {\pi \omega _0^{2}}{M^{2}\lambda _p}$, where $\omega _0$ is the beam waist at the focus position, $M^{2}$ is the beam quality factor and $\lambda _p$ is the pump wavelength. The $\mathbin {\!/\mkern -5mu/\!}$ ($\perp$) direction is defined as the direction parallel (orthogonal) to the phase matching plane.

Improvements in the model (e.g. improved approximations for ray tracing of the curved optics) will help to match the experimental results and provide better predictions about the overall source performance. Additionally, an extension of this work would be the use of elliptical collection modes that are tailored to the pump profile and crystal anisotropy.

When considering asymmetric effects of the phase matching conditions on the SPDC profile, the use of a correctly oriented elliptical pump mode showed improved in-fiber brightness over the traditional circular symmetric modes. This deviates from experimental results in SHG in optical parametric oscillators, where the marginal improvement in performance did not warrant the expense of increased experimental complexity. Elliptical pump modes have already improved the brightness of entangled photon pairs sources where the crystal geometry allows an elliptical pump mode to be implemented [8,15].

In many modern SPDC sources the pump is typically obtained from a laser diode which inherently exhibits an elliptical profile. Taking into account crystal anisotropy and beam walk-off it might be unnecessary to correct the elliptical pump profile, simplifying the construction of photon pair sources while improving performance.

Funding

National Research Foundation Singapore (NRF-CRP12-2013-02).

Acknowledgments

The authors thank the Prime Minister’s Office of Singapore and the Ministry of Education of Singapore.

References

1. D. Bouwmeester, J.-W. Pan, K. Mattle, M. Eibl, H. Weinfurter, and A. Zeilinger, “Experimental quantum teleportation,” Nature 390(6660), 575–579 (1997). [CrossRef]  

2. J. Yin, Y. Cao, Y.-H. Li, S.-K. Liao, L. Zhang, J.-G. Ren, W.-Q. Cai, W.-Y. Liu, B. Li, H. Dai, G.-B. Li, Q.-M. Lu, Y.-H. Gong, Y. Xu, S.-L. Li, F.-Z. Li, Y.-Y. Yin, Z.-Q. Jiang, M. Li, J.-J. Jia, G. Ren, D. He, Y.-L. Zhou, X.-X. Zhang, N. Wang, X. Chang, Z.-C. Zhu, N.-L. Liu, Y.-A. Chen, C.-Y. Lu, R. Shu, C.-Z. Peng, J.-Y. Wang, and J.-W. Pan, “Satellite-based entanglement distribution over 1200 kilometers,” Science 356(6343), 1140–1144 (2017). [CrossRef]  

3. A. Poppe, A. Fedrizzi, R. Ursin, H. Böhm, T. Lorünser, O. Maurhardt, M. Peev, M. Suda, C. Kurtsiefer, H. Weinfurter, T. Jennewein, and A. Zeilinger, “Practical quantum key distribution with polarization entangled photons,” Opt. Express 12(16), 3865–3871 (2004). [CrossRef]  

4. B. Bell, S. Kannan, A. McMillan, A. S. Clark, W. J. Wadsworth, and J. G. Rarity, “Multicolor quantum metrology with entangled photons,” Phys. Rev. Lett. 111(9), 093603 (2013). [CrossRef]  

5. D. C. Burnham and D. L. Weinberg, “Observation of simultaneity in parametric production of optical photon pairs,” Phys. Rev. Lett. 25(2), 84–87 (1970). [CrossRef]  

6. P. G. Kwiat, E. Waks, A. G. White, I. Appelbaum, and P. H. Eberhard, “Ultrabright source of polarization-entangled photons,” Phys. Rev. A 60(2), R773–R776 (1999). [CrossRef]  

7. A. Fedrizzi, T. Herbst, A. Poppe, T. Jennewein, and A. Zeilinger, “A wavelength-tunable fiber-coupled source of narrowband entangled photons,” Opt. Express 15(23), 15377–15386 (2007). [CrossRef]  

8. A. Villar, A. Lohrmann, and A. Ling, “Experimental entangled photon pair generation using crystals with parallel optical axes,” Opt. Express 26(10), 12396–12402 (2018). [CrossRef]  

9. G. Boyd and A. Ashkin, “Theory of parametric oscillator threshold with single-mode optical masers and observation of amplification in LiNbO$_3$,” Phys. Rev. 146(1), 187–198 (1966). [CrossRef]  

10. G. Boyd and D. Kleinman, “Parametric interaction of focused Gaussian light beams,” J. Appl. Phys. 39(8), 3597–3639 (1968). [CrossRef]  

11. V. Volosov, “Effect of laser and medium parameters on second-harmonic generation,” Sov. Phys. Tech. Phys. 14, 1652–1658 (1970).

12. D. Kuizenga, “Optimum focusing conditions for parametric gain in crystals with double refraction,” Appl. Phys. Lett. 21(12), 570–572 (1972). [CrossRef]  

13. A. Steinbach, M. Rauner, F. Cruz, and J. Bergquist, “CW second harmonic generation with elliptical Gaussian beams,” Opt. Commun. 123(1-3), 207–214 (1996). [CrossRef]  

14. T. Freegarde, J. Coutts, J. Walz, D. Leibfried, and T. Hänsch, “General analysis of type I second-harmonic generation with elliptical Gaussian beams,” J. Opt. Soc. Am. B 14(8), 2010–2016 (1997). [CrossRef]  

15. A. Lohrmann, A. Villar, A. Stolk, and A. Ling, “High fidelity field stop collection for polarization-entangled photon pair sources,” Appl. Phys. Lett. 113(17), 171109 (2018). [CrossRef]  

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (4)

Fig. 1.
Fig. 1. (a) Side view of the pump spatial walk-off (blue line) within the crystal. The collinear SPDC emission is depicted by red arrows. The dotted line is the crystal’s optical axis. (b) Sketch adapted from [12] representing the overlap between the pump beam (solid lines) and the downconversion beams (dotted lines), depicting the importance of controlling the pump focusing in order to maximize the overlap. (c) Collinear SPDC emission profile at the exit face of the crystal when the major axis of the pump ellipse (inset) is parallel to the walk-off direction. (d) Same as (c) but the ellipse major axis is rotated by 90$^\circ$. (e) Experimental setup, 1: single-mode fiber pump output, 2: collimation lens (focal length: 4.02 mm), 3: cylindrical lens 1 (CL1), 4: cylindrical lens 2 (CL2), 5: focusing lens (FL), 6: BBO crystal, 7-8: dichroic mirror and long-pass filter, respectively, to remove excess pump light, 9: achromatic collection lens; 10: single-mode fiber, 11: photon separation via a dichroic mirror followed by coincidence detection setup.
Fig. 2.
Fig. 2. Optimization curves for circular symmetric beams reported in [10]. For different walk-off parameter $B$ (shown above each curve), $\xi$ (ratio between crystal length and the confocal parameter $b$, x-axis) and the figure of merit $h_m(B,\xi )$. Resorting to the appropriate curve and knowing the walk-off angle and the length of the crystal, the optimal circular symmetric beam for a particular wavelength $\lambda _0$ can be determined.
Fig. 3.
Fig. 3. Results for the regime where the major axis of the pump ellipse is parallel to the walk-off direction. (a) Simulated in-fiber brightness at different collection beam waists for different pump aspect ratios. The shaded area indicates 1 s.d. confidence interval assuming Poisson statistics. (b) CCD camera images of the pump at the crystal position. (c) Experimentally observed brightness at different collection beam waists for different pump aspect ratios.
Fig. 4.
Fig. 4. Results for the regime where the major axis of the pump ellipse is orthogonal to the walk-off direction. (a) Simulated in-fiber brightness at different collection beam waists for different pump aspect ratios. Here, the ellipse is rotated 90° with respect to the data presented in Fig. 3. The shaded area indicates 1 s.d. confidence interval assuming Poisson statistics. (b) CCD camera images of the pump at the crystal position. (c) Experimental in-fiber brightness at different collection beam waists for different pump aspect ratios.

Tables (3)

Tables Icon

Table 1. Focal length of the lenses utilized to implement different aspect ratios in the data presented in Fig. 3(c). CL: cylindrical lens, FL: focusing lens.

Tables Icon

Table 2. Focal length of the lenses utilized to implement different aspect ratios in the data presented in Fig. 4(c). CL: cylindrical lens, FL: focusing lens.

Tables Icon

Table 3. The Rayleigh length is defined as z R = π ω 0 2 M 2 λ p , where ω 0 is the beam waist at the focus position, M 2 is the beam quality factor and λ p is the pump wavelength. The / / ( ) direction is defined as the direction parallel (orthogonal) to the phase matching plane.

Equations (2)

Equations on this page are rendered with MathJax. Learn more.

B = ρ 2 ( l k 0 ) 1 / 2 ,
A = e ( ω x Δ k x ) 2 + ( ω y Δ k y ) 2 2 sinc ( l Δ k z 2 ) 2 .
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.