Abstract
We developed a modular approach for biochemical sensing using aptamer-based microparticles and swept-source OCT. Tuning the crosslinker composition of the microparticle enabled varying physicochemical responses to a target biochemical, ranging from degradation to reversible swelling, which was spatiotemporally monitored in tissue-mimics using OCT.
© 2022 The Author(s)
PDF ArticleMore Like This
Brecken Blackburn, Matthew McPheeters, Michael W. Jenkins, William J. Dupps, and Andrew M. Rollins
CW1E.6 Optical Coherence Tomography (OCT) 2022
James A. Tummon Simmons, Nima Abbasi, James Tweel, and Parsin Haji Reza
OM2D.5 Optical Tomography and Spectroscopy (OT&S) 2022
Yijie Zhang, Tairan Liu, Manmohan Singh, Ege Çetintaş, Yilin Luo, Yair Rivenson, Kirill V. Larin, and Aydogan Ozcan
AM5I.7 CLEO: Applications and Technology (CLEO:A&T) 2022