Abstract
In this invited paper we introduce several types of waveguide spectrometers. We present a high-resolution 50-channel AWG spectrometer, including its use to interrogate a fibre Bragg grating sensor with a high wavelength accuracy of 1 pm. A 40-channel AWG operating in a broad wavelength range of 1250–1550 nm is introduced. We present a new 15-channel CWDM demultiplexer using a single curved Si-wire waveguide with an etched sidewall grating and chip size of only 90 µm × 140 µm. Finally, the first planar waveguide Fourier-transform spectrometer is presented, with a greatly increased light gathering capability and a static design.
© 2009 Optical Society of America