Abstract
The poor temporal resolution of S-cone vision is often attributed to the confinement of S-cone signals to sluggish chromatic pathways, but it could also reflect a deficit in the S-cones themselves. This question can be resolved psychophysically if the S-cone signal can be measured through the faster achromatic pathway. This is possible on intense orange fields, on which the S-cone response can be followed to nearly 30 Hz. Moreover, if S-cone flicker is combined with suprathreshold L-cone flicker at a slightly mistuned frequency, visible beats at the difference frequency can be detected for frequencies as high as 40 Hz. On these intense fields, we can distinguish two S-cone pathways: one with a low-pass frequency response that detects little above 12 Hz, and a second with a more extended bandpass response. The bandpass signal is capable of participating in flicker photometric nulls with M- and L-cone signals and shows a high frequency sensitivity loss that is not greatly different from the other cones, suggesting that S-cones are brisk and can feed the achromatic luminance channel. The luminance input is negative, but this is complicated by phase lags that can reach 180° at 18 Hz.
© 1991 Optical Society of America
PDF ArticleMore Like This
Andrew Stockman, Ethan Montag, and Donald MacLeod
MKK3 OSA Annual Meeting (FIO) 1991
Rhea T. Eskew, Charles F. Stromeyer, and Richard E. Kronauer
WR2 OSA Annual Meeting (FIO) 1990
Roger Knight, Steven L. Buck, and Elizabeth Sanocki
MKK4 OSA Annual Meeting (FIO) 1991