Abstract
In this study, the resonance mode frequencies of two model corneas were acoustically stimulated and measured with optical coherence tomography vibrography. Cycling the intraocular pressure resulted in observable hysteresis in resonance frequencies.
© 2022 The Author(s)
PDF Article | Presentation VideoMore Like This
Mitchell A. Kirby, Maju Kuriakose, Hong-Cin Liou, Ivan Pelivanov, Matthew O’Donnell, Ruikang K. Wang, and Tueng Shen
CTu4E.3 Optical Coherence Tomography (OCT) 2022
Fernando Zvietcovich, Achuth Nair, Manmohan Singh, Salavat R. Aglyamov, Michael D. Twa, and Kirill V. Larin
CTu4E.1 Optical Coherence Tomography (OCT) 2022
Maciej Wojtkowski, Ewa Mączyńska, Bartłomiej Kałużny, and Ireneusz Grulkowski