Abstract
Spectrally resolved white-light phase-shifting interference microscopy can be used for rapid and accurate measurements of the thickness profile of transparent thin-film layers deposited upon patterned structures exhibiting steps and discontinuities. We examine the sensitivity of this technique and show that it depends on the thickness of the thin-film layer as well as its refractive index. The results of this analysis are also valid for any other method based on measurements of the spectral phase such as wavelength scanning or white-light interferometry.
© 2006 Optical Society of America
Full Article | PDF ArticleMore Like This
Sanjit K. Debnath, Mahendra P. Kothiyal, Joanna Schmit, and Parameswaran Hariharan
Opt. Express 14(11) 4662-4667 (2006)
Sanjit K. Debnath, Seung-Woo Kim, Mahendra P. Kothiyal, and Parameswaran Hariharan
Appl. Opt. 49(34) 6624-6629 (2010)
Yeongchan Cho, Seung Woo Lee, Sin Yong Lee, Garam Choi, and Heui Jae Pahk
Appl. Opt. 60(30) 9425-9431 (2021)