Abstract
Analyses based on quantum metrology have shown that the ability to localize the positions of two incoherent point sources can be significantly enhanced over direct imaging through the use of mode sorting. Here we theoretically and experimentally investigate the effect of partial coherence on the sub-diffraction limit localization of two sources based on parity sorting. With the prior information of a negative and real-valued degree of coherence, higher Fisher information is obtained than that for the incoherent case. Our results pave the way to clarifying the role of coherence in quantum-limited metrology.
© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Corrections
S. A. Wadood, Kevin Liang, Yiyu Zhou, Jing Yang, M. A. Alonso, X.-F. Qian, T. Malhotra, S. M. Hashemi Rafsanjani, Andrew N. Jordan, Robert W. Boyd, and A. Nick Vamivakas, "Experimental demonstration of superresolution of partially coherent light sources using parity sorting: erratum," Opt. Express 29, 35579-35579 (2021)https://opg.optica.org/oe/abstract.cfm?uri=oe-29-22-35579
1. Introduction
The resolution of imaging systems is limited by the size of the diffraction-limited point spread function (PSF) [1]. To quantify this resolution, the Rayleigh criterion has been proposed and widely used [2]. Recently, the analysis of optical resolution has been recast in terms of Fisher Information (FI) [3–5], which quantifies the precision of measurements and is inversely proportional to the parameter estimation error. Generally, the FI of the estimation of separation $\delta$ between two spatially incoherent point sources depends on the type of measurement performed on the image plane field. In the case of direct detection of image plane intensity, the FI goes to zero as $\delta \rightarrow 0$, an effect termed as Rayleigh’s curse. In their seminal work [3], Tsang et al. showed that Rayleigh’s curse can be overcome if the optical field is detected by an appropriate spatial mode demultiplexer (SPADE), given prior knowledge of two equally bright and incoherent point sources versus a single emitter. It has been verified experimentally, as a demonstration of superresolution over direct imaging, that the FI for such a scheme is constant as $\delta \rightarrow 0$ [6–10].
The sources, however, can have a non-zero coherence between them [11]. In fact, spatial coherence is a key parameter affecting the resolution of imaging systems [12]; coherent illumination techniques can offer enhanced resolution in microscopy [13] and two-point direct imaging [14,15]. Moreover, coherence imaging can offer significant practical advantages over conventional direct imaging systems, for example in the very long baseline radio interferometry (VLBI) used for black hole imaging [16]. It is then natural to ask how spatial coherence between the two sources affects the resolution obtained by SPADE. Recent theoretical works have extended the scope of the two-point estimation problem to include the general case of partial coherence among the two sources [17–22]. In particular, it was shown that Rayleigh’s curse can still be avoided for a known degree of spatial coherence $\gamma$ [18,19,22]. For the case of $\gamma <0$, an even greater sensitivity for SPADE was predicted than the incoherent case. The increased sensitivity needs to be carefully interpreted, taking into account photon budgeting considerations [21]. Experimental demonstration of SPADE with partial coherence, however, has been lacking. The main result of our work is to experimentally demonstrate the breaking of Rayleigh’s curse for partially coherent light sources using SPADE. In doing so, we also distill and connect the different elements of previous theoretical works.
In Section 2, we derive the classical FI of our experimental setup for partially coherent fields. Special attention is paid to a priori assumptions and how they affect the obtained FI. The connection between previous works is also made clear in this section. Section 3 explains the experimental setup, the generation of spatial coherence, and a discussion of estimation statistics. Section 4 summarizes the results.
2. Theory
In this section we outline the calculation of the classical FI for parity sorting of partially coherent fields. Note that parity sorting falls under the scheme of binary SPADE (BSPADE), which is a family of measurements that simplifies SPADE at the cost of losing large-delta information [3,23]. For the sub-Rayleigh regime, it has been shown that a measurement of the even and odd projections of the input field has an FI that converges to the quantum optimal FI [7,9]. Here we show explicitly how different a priori assumptions yield different FI curves. The physical problem is the following: Two point sources separated by $\delta$ and having a degree of spatial coherence $\gamma$ are imaged by an imaging system with a finite-sized aperture and a characteristic PSF width $\sigma$. The goal is to perform quantum-limited estimation of $\delta$ in the sub-Rayleigh regime ($\delta <\sigma$) by performing parity sorting on the image plane field.
A partially coherent field is described by its cross-spectral density (CSD) function $W(x_{1},x_{2})$ [11]. To proceed, we first note that $W$ can be decomposed via the coherent mode decomposition (CMD) [24]. For our problem, the simplest choice of modes is to decompose $W$ in the symmetric (in phase) and antisymmetric (out of phase) combinations of the two sources. In the image plane, $W(x_{1},x_{2})$ is given as
where $N_{0}$ is the average object plane photon number emitted by each point source, $\kappa$ is a space-invariant efficiency factor dictated by the aperture loss, $\phi _{k}(x)=f_{+}(x)-e^{i k \pi }f_{-}(x)$ are the symmetric ($k=1$) and antisymmetric ($k=2$) coherent modes, $f_{\pm }(x)=f(x\pm \delta /2)$ are the two point spread functions separated by $\delta$ - the parameter to be estimated, $p_{k}$ is a real number such that $0\leq p_{k}\leq 1$, and $p_{1}+p_{2}=1$. In what follows, the terms even and odd modes are used interchangeably with symmetric and antisymmetric modes. We assume Gaussian PSFs of width $\sigma$ such that $f(x)=\frac {e^{-x^2/4\sigma ^2}}{(2\pi \sigma ^2)^{1/4}}$ is the field PSF. The total number of photons in the image plane is given by where $d=\int dx f_{+}(x)f_{-}(x)=e^{-\delta ^2/(8\sigma ^2)}$ is the overlap integral of the two shifted PSFs, and $\gamma =p_{1}-p_{2}$ is an effective degree of spatial coherence between the two sources. It is here that we first encounter the departure from the incoherent estimation problem; for $\gamma \neq 0$, $N_{t}$ depends on the parameter $\delta$ to be estimated. Hence, it is necessary to spend some time clarifying the interpretation of the FI for partially coherent sources. For a parity sorter, the photon numbers in the even and odd ports are, respectively,Equations (2) and (3) are derived in Supplement 1, Section S1. We assume that $\gamma ,\kappa$ are known a priori. If we know $N_{0}$ and the only unknown in the experiment is $\delta$, then assuming Poisson statistics it can be shown [3] that the FI for parity sorting is given by
It is not uncommon, however, that an experimentalist only has access to image plane photons, and does not have knowledge of $N_{0}$. When both $\delta$ and $N_{0}$ are unknown, the FI is found from the multiparameter Cramer–Rao bound (CRB); this FI is given by
We can now ask the more practical question of how to estimate $\delta$ when we only detect the image plane field, and have no knowledge of $N_{0}$ ? In this case one can use the normalized modal weights $m_{1,2}=N_{1,2}/N_{t}$ which are independent of $N_{0}$. The statistics are described in this case by a binomial likelihood function [25]. We can then calculate the image plane FI by the formula
Incidentally, the aforementioned discussion provides clarity to the debate between, among others, the Tsang–Nair (TN) model [18] and the Larson–Saleh (LS) model [19]. Strictly speaking, the TN model assumes knowledge of $N_{0}$, while the LS model assumes an unknown $N_{0}$. Specifically, Fig. 1(a) agrees with the TN model, and Fig. 1(c) agrees with the LS model. Figure 1(b) bridges the TN and LS models. We note that Hradil et. al. [21] also advocated the use of the weighted version of image plane FI to take into account the image plane photon number variation with $\gamma ,\delta$, and their results also imply the curves in Fig. 1(b). Depending on the a priori assumptions afforded by the experimental setup, either TN or LS models will correctly describe the estimation statistics. Note that a similar observation has been made for coherent microscopy [26], which advocates the ‘mandatory inclusion of information about underlying a priori assumptions’ when discussing resolution claims.
We mention that the parity sorter achieves a quantum limited performance. To see this, note that our classical FI calculations coincide with the predictions of the quantum FI in [19,21] for a known $\delta ,\gamma$ and unknown $N_{0}$. The notion of a quantum FI for a known $N_{0}$ is still being actively explored [27], and is beyond the scope of this work.
Having clarified the issue of the FI interpretation for partial coherence, we can now proceed to discuss the experiment. Realistically, we will use the image plane model as it reflects a common situation in imaging, microscopy, and astronomy. Note that realistic situations have more than just $\delta$ and $N_{0}$ as possible unknowns. For example, our analysis till now has assumed the presence of only two sources, equal intensities of the two sources, a known centroid of the objects to which the parity sorter is aligned, and, most importantly, a known $\gamma$. In practice, one needs a combination of direct imaging, coherence interferometry, and parity sorting to estimate these unknown parameters. The application of quantum metrology-inspired ideas such as SPADE to practical situations is an active field of research [28–31]. These considerations, however, are not relevant to our proof-of-principle experiment in which we consider only $\delta$ and $N_{0}$ as the unknown parameters.
3. Experiment
3.1 Generation of partial coherence
We use a parity sorter to perform SPADE on two spatially partially coherent sources. To generate partial coherence, we use the CMD [24]. Physically, such a CMD means that the spatial coherence at the input plane to the SPADE setup can be engineered by incoherently mixing appropriately scaled symmetric and antisymmetric modes. This can be realized by adding a path difference between coherent modes that is larger than the laser coherence length. Alternatively, we can ‘switch’ between the modes in time, with the switching time longer than the laser coherence time, and add the recorded intensities digitally [32,33]. The CMD therefore allows us to generate spatial coherence ‘offline’, by performing the intensity summation electronically. To generate an intensity distribution corresponding to a specific $\gamma$ in Eqs. (3), we can post-select from a set of recorded intensities of $\phi _{1,2}$ modes. This allows a great simplification of the experiment with respect to the precise control of $\gamma$. Nevertheless, the CMD technique has a physical drawback; we are not looking at two real point sources, but at the image plane field generated as if the point sources with a given $\delta$ and $\gamma$ were actually present. Due to this characteristic of CMD, we cannot access the object plane curves of Figs. 1(a) and 1(b), as is also explained at the end of Section 3.3.
Figure 2(a) shows the coherent mode generation portion of the setup, which contains an SLM and a $4f$ spatial filter. The coherent modes for a particular $\delta$ are generated via a phase grating implemented on a spatial light modulator (SLM). The SLM can be used to generate a field $\psi (x,y)$ with an arbitrary transverse amplitude and phase profile. To that end, we implement a phase grating $\exp {[i(\Pi (x,y))]}$ on the SLM. The grating is constrained such that the first-order term in its Fourier expansion equals $\psi (x,y)=\phi _{k}(x)f(y)$, where $\phi _{k}(x)$ is the $k^{th}$ coherent mode and $f(y)$ is the Gaussian PSF defined after Eq. (1). We add a linear phase grating and use a $4f$ spatial filter to isolate the first diffraction order, which is proportional to $\psi (x,y)$. The details on the algorithm to ‘encode’ the field into the phase grating are given in [34]. Note that there are limits set on the spatial frequency content of the beams that can be generated. These limits are dictated primarily by the pixel pitch of the SLM, and the range of phase modulation that the liquid crystals can impart. The SLM model used in our experiment is HAMAMATSU X10468-02, which has a pixel pitch of $20 \mu m$ and a phase modulation range of $2\pi$. Due to the small pixel pitch, any discretization effects are negligible in our experiment. The SLM only responds to a horizontally polarized beam (polarization axis parallel to the optical table). The inset in Fig. 2(a) shows the phase grating implemented on the SLM to generate the coherent modes. The high spatial frequency fringes show the linear grating implemented to separate the desired mode on the first diffraction order. Note that the phase mask is qualitatively very similar to the beam itself. The beam is relayed to the parity sorter, shown in Fig. 2(b), with $4f$ systems. The symmetric or antisymmetric modes generated via the SLM have $\sigma =327\pm 4\mu m$. Note that we are not changing the temporal coherence properties; all the beams used are quasimonochromatic and therefore temporally coherent.
3.2 SPADE using parity sorting
After generating partially coherent fields, the next step is to perform parity sorting on the field described by Eq. (1). The beam flux can be adjusted using polarization optics. The parity sorter consists of a Michelson type image inversion interferometer that sorts the input field based on its parity, as shown in Fig. 2(b). Figure 2(b) shows the top arm having 2 SLMs separated by a distance of $600\textrm {mm}$. SLM 2 has a focal length of $600~\textrm {mm}$ and SLM 3 a focal length of $300~\textrm {mm}$. The optical power on SLM 2 cancels the quadratic phase at the image plane of SLM 3, which coincides with the SLM 2 plane. The top arm is then effectively equivalent to a $2f$ imaging system, with an extra quadratic phase to cancel the defocus due to diffraction, and implements the transformation $(x) \rightarrow (-x)$. The reference arm with the $4f$ system images the field with unity magnification, after two reflections. The global phase difference $\theta$ between the two arms for the signal beam is also implemented on SLM 3. Experimental details of the interferometer are described in Ref. [35] (For parity sorting, we set $\alpha =\pi$ in Eqs. (1–3) of Ref. [35]). The field at the output of the interferometer is
where $k=1,2$, and $N_{k}$ is the photon number in the input mode $\phi _{k}$. We remind the reader that $\phi _{k}$ is spatially coherent in Eq. (7). Note that the coherent modes used are symmetric in $y$, so the 1D analysis is valid for the experiment. The interferometer is path stabilized using a PID loop connected to a piezo on the reference arm mirror. To monitor the phase fluctuations for the PID loop, a separate vertically polarized beam (not shown in Fig. 2(b)) is sent to the interferometer, separated before the detector via a polarizing beam splitter, and its measured power is fed to the PID loop. Note that the SLMs do not respond to the vertically polarized beam.To project onto the even and odd components of the field, we can choose $\theta =0,\pi$ in Eq. (7). As explained in Section 3.1, we send only one of the coherent modes $\phi _{k}$ at a given time. To generate CSD for a given $\gamma$, we add the measured intensities offline. Details of the offline coherence generation are given in Supplement 1, Section S3. For $\theta =0 (\pi )$, all of the symmetric (antisymmetric) mode power will be directed to the detector, while the antisymmetric (symmetric) mode will destructively interfere at the detector. For $\theta =0 (\pi )$ the output is called as the even (odd) port.
3.3 Estimation Statistics
The goal of superresolution is to estimate $\delta$ for regions of $\delta <\sigma$. To estimate $\delta$, we use maximum likelihood estimation (MLE) on the measured normalized modal weights $m_{1,2}$. Sample measurements of the modal weights are shown in Supplement 1, Section S3. Because we normalize the modal weights by the image plane photons, we use a binomial likelihood function for the parity sorter [25]. The estimated $\hat {\delta }$ is shown in Fig. 3(a). Note that all the estimated $\delta$’s are below the Rayleigh limit ($\delta =\sigma$), which demonstrates the ability of the parity sorter to perform superresolution. For $\delta$ in the interval $[0.2, 1]\sigma$ (in increments of $0.1\sigma$), we take 100 images each of the symmetric and antisymmetric modes, thus getting 100 ML estimates and the corresponding variance. We have not observed any bias in the estimates, as evident in Fig. 3(a), where the mean of the estimates are equal to the true value of $\delta /\sigma$. The variance in the MLE estimates, which is related to the inverse of the FI, is too small to be noticed in Fig. 3(a). Nevertheless, the variance of an unbiased estimator is lowerbound by the Cramer–Rao bound (CRB), which is related to the inverse of the FI. Formally, $\textrm {Var}[\hat {\delta }]\geq (N_{t}F_{img})^{-1}$, where $\textrm {Var}[\hat {\delta }]$ is the variance in the MLE estimator $\hat {\delta }$, and $F_{img}$ is the image plane FI as given by Eq. (6) and shown in Fig. 1(c). Figure 3(b) shows the normalized Mean Square Error (MSE) $=N_{t}\textrm {Var}[\hat {\delta }]$ as a function of $\delta$ and two values of $\gamma =0,-0.75$. More importantly, Fig. 3(b) shows that the MSE for $\gamma =-0.75$ is below the CRB for the $\gamma =0$ case. In other words, not only is Rayleigh’s curse avoided for $\gamma =-0.75$, the estimation is more precise than the incoherent case of $\gamma =0$. Note that the MSE are still offset from the CRB. To truly saturate the CRB, the system must be shot noise limited, and any other noise source will raise the MSE. Apart from shot noise, another source of noise in our system are the phase fluctuations in the interferometer when it is biased at $\theta =0~\textrm {or}~\pi$ (See Fig. 2(b)). Furthermore, the MSE for $\gamma =0,-0.75$ might appear correlated, for example at $\delta =0.2,0.3$. This is because the same set of images are used for CMD of both $\gamma =0,-0.75$, and hence both $\gamma =0,-0.75$ MSE’s will be affected by the same phase fluctuations; if the $\gamma =0$ MSE is higher, so will be the $\gamma =-0.75$ MSE. Finally, the CRB curves in Fig. 3(b) are nearly equivalent to the quantum CRB predicted for $\delta <\sigma$ [19], and therefore our measurements represent near quantum-limited localization of partially coherent sources [36].
The reader might observe that no statistics for $|\gamma |=1$ are shown in Fig. 3. As discussed in Section (2), the FI for $|\gamma |=1$ is zero for all $\delta$ if $N_{0}$ is unknown. The likelihood function in this case is independent of $\delta$ for $|\gamma |=1$, and hence $\delta$ cannot be estimated in principle. $~N_{0}$ is unknown in our experiment because we generate the image plane field directly through unitary transformations and not through a Gaussian aperture that scales the coherent modes according to the $(1\pm d)$ factor in Eqs. (3). While our system has an effective ‘aperture’ loss factor that connects the source photon number to the image plane photon number, this loss factor is independent of $\delta$ for the coherent modes generated by the SLM, as is also reported in Supplement 1, Section S4. The experiment is the generalization of previous localization experiments on incoherent beams [7,9]. This technique allows 1) a great experimental simplification with regard to avoiding the need to perform precise fabrication of point sources with different separations and 2) to circumvent issues of low photon budget and spurious diffraction effects from the source geometries. However, this technique fails to provide access to an effective object plane photon number which is related to the image plane photon number by the factor of $(1+\gamma d)$, and hence does not allow us to reconstruct results of Figs. 1(a) and 1(b). Barring these technical difficulties, our theoretical and experimental results are easily generalized to the case of a known $N_{0}$. We note that having access to only the image plane photon number is however a common situation in optical physics, where one does not have an independent probe on the object plane photons. Our results are therefore valid for a large variety of microscopy and imaging experiments. The details of image processing and the photon number in Fig. 3 versus $\delta$ are given in Supplement 1, Section S4.
4. Conclusion and outlook
We have carried out a theoretical analysis of superresolution of partially coherent light sources using parity sorting. For partially coherent sources, the object plane photon number was identified as a relevant parameter that affects the obtainable FI, and that connects the different results of previous works [18,19,21]. We also performed parity sorting on two Gaussian PSFs with varying degrees of spatial coherence. Our results show that partial anticorrelation of the two sources increases the FI of $\delta$ estimation. Therefore, Rayleigh’s curse can be avoided for partially coherent sources. The proof-of-principle experiment paves the way to using coherence as a resource in quantum-limited metrology. Our analysis assumes a real, known value of $\gamma$. Further studies could include concurrent estimation of $\delta$ and $\gamma$, for which a vanishing FI with $\delta \rightarrow 0$ is predicted [17,22]. The natural extension of the current work is to consider the more realistic case of multiparameter estimation of a complex $\gamma$, the centroid and intensity ratio of the two sources [22], and the effects of cross-talk in the SPADE setup [28–30,37]. While we have been primarily concerned with the two-point problem, the technique of SPADE can also tackle the more general problem of imaging an extended object scene. There the problem reduces to estimation of moments of the object in the sub-diffraction limit, a case which was treated for incoherent objects [4,38–40]. It is an open question as to how these theoretical works generalize to the case of partially coherent object distributions.
Funding
Excellence Initiative of Aix-Marseille University— A*MIDEX, a French ``Investissements d’Avenir'' program; Natural Sciences and Engineering Research Council of Canada (RGPIN/2017-06880); Office of Naval Research (N00014-19-1-2247); National Science Foundation (OMA-1936321, PHY-1507278); Defense Advanced Research Projects Agency (D19AP00042).
Acknowledgements
The authors acknowledge Prof. J. R. Fienup, Dr. Walker Larson, Prof. Mankei Tsang, and Prof. Bahaa E. A. Saleh for useful discussions.
Disclosures
The authors declare that there are no conflicts of interest related to this article.
Data availability
The raw data for Fig. 3 and Supplement 1 are available from the authors upon request. The data were processed in MATLAB, and the data processing codes are also available from the authors upon request.
Supplemental document
See Supplement 1 for supporting content.
References
1. J. W. Goodman, Introduction to Fourier Optics (Roberts and Company Publishers, 2005).
2. L. Rayleigh, “Xxxi. Investigations in optics, with special reference to the spectroscope,” Lond. Edinb. Dubl. Phil. Mag. J. Sci. 8(49), 261–274 (1879). [CrossRef]
3. M. Tsang, R. Nair, and X.-M. Lu, “Quantum theory of superresolution for two incoherent optical point sources,” Phys. Rev. X 6(3), 031033 (2016). [CrossRef]
4. S. Zhou and L. Jiang, “Modern description of rayleigh’s criterion,” Phys. Rev. A 99(1), 013808 (2019). [CrossRef]
5. J. Yang, S. Pang, Y. Zhou, and A. N. Jordan, “Optimal measurements for quantum multiparameter estimation with general states,” Phys. Rev. A 100(3), 032104 (2019). [CrossRef]
6. M. Paúr, B. Stoklasa, Z. Hradil, L. L. Sánchez-Soto, and J. Rehacek, “Achieving the ultimate optical resolution,” Optica 3(10), 1144–1147 (2016). [CrossRef]
7. W.-K. Tham, H. Ferretti, and A. M. Steinberg, “Beating Rayleigh’s curse by imaging using phase information,” Phys. Rev. Lett. 118(7), 070801 (2017). [CrossRef]
8. F. Yang, A. Tashchilina, E. S. Moiseev, C. Simon, and A. I. Lvovsky, “Far-field linear optical superresolution via heterodyne detection in a higher-order local oscillator mode,” Optica 3(10), 1148–1152 (2016). [CrossRef]
9. Z. S. Tang, K. Durak, and A. Ling, “Fault-tolerant and finite-error localization for point emitters within the diffraction limit,” Opt. Express 24(19), 22004–22012 (2016). [CrossRef]
10. Y. Zhou, J. Yang, J. D. Hassett, S. M. H. Rafsanjani, M. Mirhosseini, A. N. Vamivakas, A. N. Jordan, Z. Shi, and R. W. Boyd, “Quantum-limited estimation of the axial separation of two incoherent point sources,” Optica 6(5), 534–541 (2019). [CrossRef]
11. L. Mandel and E. Wolf, Optical Coherence and Quantum Optics (Cambridge University Press, 1995).
12. J. W. Goodman, Statistical Optics (John Wiley & Sons, 2015).
13. P. Ferraro, A. Wax, and Z. Zalevsky, Coherent light microscopy: Imaging and quantitative phase analysis, vol. 46 (Springer Science & Business Media, 2011).
14. D. N. Grimes and B. J. Thompson, “Two-point resolution with partially coherent light,” J. Opt. Soc. Am. 57(11), 1330–1334 (1967). [CrossRef]
15. V. Nayyar and N. Verma, “Two-point resolution of gaussian aperture operating in partially coherent light using various resolution criteria,” Appl. Opt. 17(14), 2176–2180 (1978). [CrossRef]
16. The Event Horizon Telescope Collaboration, et al. “First m87 event horizon telescope results. i. the shadow of the supermassive black hole,” Astrophys. J., Lett. 875(1), L1 (2019). [CrossRef]
17. W. Larson and B. E. Saleh, “Resurgence of Rayleigh’s curse in the presence of partial coherence,” Optica 5(11), 1382–1389 (2018). [CrossRef]
18. M. Tsang and R. Nair, “Resurgence of Rayleigh’s curse in the presence of partial coherence: comment,” Optica 6(4), 400–401 (2019). [CrossRef]
19. W. Larson and B. E. Saleh, “Resurgence of Rayleigh’s curse in the presence of partial coherence: reply,” Optica 6(4), 402–403 (2019). [CrossRef]
20. K. K. Lee and A. Ashok, “Surpassing Rayleigh limit: Fisher information analysis of partially coherent source (s),” in Optics and Photonics for Information Processing XIII, vol. 11136 (International Society for Optics and Photonics, 2019), vol. 11136, p. 111360H.
21. Z. Hradil, J. Řeháček, L. Sánchez-Soto, and B.-G. Englert, “Quantum fisher information with coherence,” Optica 6(11), 1437–1440 (2019). [CrossRef]
22. K. Liang, S. A. Wadood, and A. Vamivakas, “Coherence effects on estimating two-point separation,” Optica 8(2), 243–248 (2021). [CrossRef]
23. J. Hassett, T. Malhorta, M. Alonso, R. Boyd, S. H. Rafsanjani, and A. Vamivakas, “Sub-rayleigh limit localization with a spatial mode analyzer,” in “Frontiers in Optics,” (Optical Society of America, 2018), pp. JW4A–124.
24. E. Wolf, “New spectral representation of random sources and of the partially coherent fields that they generate,” Opt. Commun. 38(1), 3–6 (1981). [CrossRef]
25. M. Tsang, R. Nair, and X.-M. Lu, “Quantum information for semiclassical optics,” in Quantum and Nonlinear Optics IV, vol. 10029 (International Society for Optics and Photonics, 2016), p. 1002903.
26. R. Horstmeyer, R. Heintzmann, G. Popescu, L. Waller, and C. Yang, “Standardizing the resolution claims for coherent microscopy,” Nat. Photonics 10(2), 68–71 (2016). [CrossRef]
27. Z. Hradil, D. Koutnỳ, and J. Řeháček, “Exploring the ultimate limits: super-resolution enhanced by partial coherence,” Opt. Lett. 46(7), 1728–1731 (2021). [CrossRef]
28. J. de Almeida, J. Kołodyński, C. Hirche, M. Lewenstein, and M. Skotiniotis, “Discrimination and estimation of incoherent sources under misalignment,” Phys. Rev. A 103(2), 022406 (2021). [CrossRef]
29. M. Gessner, C. Fabre, and N. Treps, “Superresolution limits from measurement crosstalk,” Phys. Rev. Lett. 125(10), 100501 (2020). [CrossRef]
30. P. Boucher, C. Fabre, G. Labroille, and N. Treps, “Spatial optical mode demultiplexing as a practical tool for optimal transverse distance estimation,” Optica 7(11), 1621–1626 (2020). [CrossRef]
31. M. R. Grace, Z. Dutton, A. Ashok, and S. Guha, “Approaching quantum-limited imaging resolution without prior knowledge of the object location,” J. Opt. Soc. Am. A 37(8), 1288–1299 (2020). [CrossRef]
32. B. Rodenburg, M. Mirhosseini, O. S. Magaña-Loaiza, and R. W. Boyd, “Experimental generation of an optical field with arbitrary spatial coherence properties,” J. Opt. Soc. Am. B 31(6), A51–A55 (2014). [CrossRef]
33. X. Chen, J. Li, S. M. H. Rafsanjani, and O. Korotkova, “Synthesis of Im-Bessel correlated beams via coherent modes,” Opt. Lett. 43(15), 3590–3593 (2018). [CrossRef]
34. V. Arrizón, U. Ruiz, R. Carrada, and L. A. González, “Pixelated phase computer holograms for the accurate encoding of scalar complex fields,” J. Opt. Soc. Am. A 24(11), 3500–3507 (2007). [CrossRef]
35. T. Malhotra, W. E. Farriss, J. Hassett, A. F. Abouraddy, J. R. Fienup, and A. N. Vamivakas, “Interferometric spatial mode analyzer with a bucket detector,” Opt. Express 26(7), 8719–8728 (2018). [CrossRef]
36. Recall that BSPADE uses only two sets of modes, and the odd modes contain most of the FI for the sub-Rayleigh regime. Thus the BSPADE CRB is very close to the quantum CRB for δ < σ, and both are exactly equal in the limit δ → 0.
37. G. Sorelli, M. Gessner, M. Walschaers, and N. Treps, “Optimal observables for practical super-resolution imaging,” arXiv preprint arXiv:2102.05611 (2021).
38. M. Tsang, “Subdiffraction incoherent optical imaging via spatial-mode demultiplexing,” New J. Phys. 19(2), 023054 (2017). [CrossRef]
39. M. Tsang, “Quantum limit to subdiffraction incoherent optical imaging,” Phys. Rev. A 99(1), 012305 (2019). [CrossRef]
40. M. Tsang, “Semiparametric bounds for subdiffraction incoherent optical imaging: a parametric-submodel approach,” arXiv preprint arXiv:2010.03518 (2020).