Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Two-photon dual-comb LiDAR

Open Access Open Access

Abstract

The interferometric signals produced in conventional dual-comb laser ranging require femtosecond lasers with long-term carrier-envelope offset frequency stability, and are limited to an upper sampling rate by radio-frequency aliasing considerations. By using cross-polarized dual combs and two-photon detection, we demonstrate carrier-phase-insensitive cross-correlations at sampling rates of up to 12× the conventional dual-comb aliasing limit, recording these in a digitizer-based acquisition system to implement ranging with sub-100 nm precision. We then extend this concept to show how the high data burden of conventional dual-comb acquisition can be eliminated by using a simple microcontroller as a ns-precision stopwatch to record the time intervals separating the two-photon cross-correlation pulses, providing real-time and continuous LiDAR-like distance metrology capable of sub-100 nm precision and dynamic acquisition for unlimited periods.

Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI.

1. Introduction

Cross-correlation time-of-flight metrology employs two frequency combs, identical in all respects except for a small difference in their repetition rates (${f_{rep}}$) of $\Delta {f_{rep}}$. One comb probes the distance to be measured using target and reference pulse sequences, while the other serves as a local oscillator (LO) that temporally gates the arrival of these pulses on a detector. The technique is a simplification of phase-coherent dual-comb metrology [1], and has been demonstrated with combs whose carrier-envelope offset frequencies are uncontrolled [2,3,4,5]; the resulting interferograms can be Hilbert-transformed to provide envelopes whose positions are localized by a Gaussian-fitting procedure. While the use of free-running combs substantially simplifies the technique, the unavoidable long-term drift in their carrier-envelope offset frequencies (${f_{CEO}}$) makes the carrier frequency of the interferograms unstable, causing Hilbert-transform processing to fail when the frequency is too low. While stable interferograms can be ensured by using fully-locked frequency combs [6,7,8], this leads to a complex system requiring four locking loops (two for ${f_{rep}}$ and two for ${f_{CEO}}$). Previously, distance metrology that was insensitive to variations in ${f_{CEO}}$ was implemented by cross-correlating orthogonally polarized probe and LO pulses in two Type II BBO crystals [9]. A peak-fitting algorithm was applied to the digitized cross-correlation traces to extract the target-reference path distance. The related balanced optical cross-correlation technique was implemented using a periodically-poled potassium titanyl phosphate (PPKTP) crystal [10,11], providing a signal whose zero-crossings could be used to localize the coincidence of the LO and target / reference pulses. Both techniques achieved precisions comparable to the original dual-comb time-of-flight demonstration [2], although introduced greater complexity in the form of multiple detectors and nonlinear crystals.

An alternative to schemes using nonlinear crystals is two-photon cross-correlation, which is already well established as a method for optical pulse measurement [12,13] and offers multiple benefits over an interferometric dual-comb signal. Similar to cross-correlation in Type II crystals, the non-interferometric nature of the two-photon cross-correlation signal removes the need to phase-stabilize the participating lasers. Normally dual-comb metrology requires tight optical phase control of the two combs so that the interferogram carrier frequency is stable. When the carrier-envelope offset frequencies of the lasers are not actively stabilized, even tiny environmental changes can cause the interferogram carrier frequency to fluctuate rapidly across the full DC to ${f_{rep}}/2$ range, again making envelope extraction problematic. Two-photon cross-correlation is immune to this effect, allowing the use of lasers with free-running ${f_{CEO}}$ frequencies.

Unlike interferometric dual-comb methods, the lasers can also operate at different wavelengths without impacting the two-photon signal, and enabling the constraints on the laser design and performance to be relaxed. Since the two-photon absorption process is not phasematched, wavelength constraints are relaxed compared to schemes that use upconversion in nonlinear crystals [911]. By utilizing a wider bandgap detector than conventional dual-comb metrology, two-photon cross-correlation is also insensitive to light at the laser wavelength, except where this takes the form of short pulses focused onto the detector. Critically, these constraints provide rejection of stray light and amplified spontaneous emission from the metrology signal, both potentially important benefits where an optical amplifier is used in the receiver channel of a dual-comb system.

Perhaps the most significant advantage of utilizing a non-interferometric signal is the elimination of the conventional dual-comb aliasing condition, which places an upper limit on the repetition rate difference between the two lasers. The interference between two combs of repetition rates ${\approx} {f_{rep}}$, and sharing a common optical frequency bandwidth of $\Delta \nu $, creates radio frequencies which uniquely map onto optical frequencies only below a maximum repetition-rate difference $\Delta {f_{rep}} < f_{rep}^2/2\Delta \nu $. As this limiting value is approached, the interferogram contains frequencies approaching DC, which modulate its shape and make time-of-flight analysis from envelope extraction unreliable. By contrast, no equivalent limitation applies to two-photon cross-correlation. The value of $\mathrm{\Delta }{f_{rep}}$ determines the metrology sampling rate, so the ability to exceed the conventional aliasing limit enables faster data acquisition, facilitating dynamic measurements and potentially improving the measurement precision in any given averaging time.

A further advantage for metrology is that the duration of the two-photon cross-correlation signal is significantly less than that of the conventional dual-comb interferogram. As described in [14], the second-order intensity cross-correlation is shorter than the first-order field cross-correlation by a factor of 0.707 for Gaussian pulses, and by a factor of 0.625 for $\textrm{sec}{\textrm{h}^2}(t )$ pulses of the kind commonly produced by soliton lasers. This considerable difference makes the two-photon cross-correlation signal particularly well suited as a signal for time-of-flight metrology, potentially enabling more precise localization of its center, and providing a more sharply rising edge for LiDAR-type timing measurements.

Here, we introduce an experimental embodiment of two-photon cross-correlation dual-comb ranging. We demonstrate acquisition well beyond the conventional dual-comb aliasing limit by directly comparing the two-photon signals with conventional one-photon dual-comb interferograms. Using the standard digitizer-based acquisition approach we obtain sub-100 nm precision in ${\approx} $ 2 seconds at an update rate of 2.4${\times} $ the conventional dual-comb aliasing limit. Finally, we show how the digital nature of the two-photon signal can be used to configure a LiDAR-like time-of-flight system that provides dynamic absolute distance measurement with few-µm instantaneous precision.

2. Distance metrology using two-photon cross-correlation

2.1 Laser and metrology system

The combs, which each followed the layout illustrated in Fig. 1(a), were SESAM-modelocked Er:fiber lasers producing pulses with durations of 418 fs and 716 fs, repetition rates of ${f_{rep}} \approx $ 78.87 MHz and center wavelengths close to 1555 nm. The lasers were based on previously reported designs [15,16] and incorporated either fiber butt-coupling or free-space focusing onto a semiconductor saturable absorber mirror (SESAM), as described in [17,18]. Both cavities comprised only polarization-maintaining (PM) fibers. The lasers were each terminated by a piezo-actuated 2% transmittance output coupler (OC), which in the LO comb was mounted on a translation stage to allow coarse tuning of the repetition rate. The output-coupled power was approximately 900 µW from each laser oscillator. A short free-space section was used to couple the light from each comb into a two-stage, non-PM Er:fiber amplifier, which boosted the probe and LO laser powers to up to 40 mW in each channel.

 figure: Fig. 1.

Fig. 1. (a) Design of the Er:fiber laser combs, in which a low-power master oscillator is free-space coupled into a two-stage amplifier with total gain of 16.5 dB. One comb was constructed to exactly this design, while the other was identical except for the use of a fiber-butt-coupled SESAM instead of free-space coupling. WDM: wavelength division multiplexer; PBS: polarizing beamsplitter; OC: output coupler. (b) Dual-comb two-photon-absorption (TPA) detection scheme. BS: non-polarizing beamsplitter; D: silicon avalanche photodetector; LPF: long-pass filter ($\lambda > $1300 nm). (c) Representative two-photon cross-correlation signal. (d) Optical spectra of the probe (blue) and LO combs (red).

Download Full Size | PDF

As shown in Fig. 1(b), pulses from the probe comb were split into two replicas by a beamsplitter, and reflected from reference and target mirrors before being recombined. The recombined pulses were prepared in an s-polarization by using quarter-wave and half-wave plates. The pulses from the LO comb were made p-polarized in a similar way before being combined with the probe pulses at a polarizing beamsplitter. In this way, the probe and LO pulses were combined with orthogonal polarizations, ensuring that no optical interference could occur. The combined beams passed through a long-pass filter to block unabsorbed 980-nm pump light before being focused onto a silicon avalanche photodiode (-3 dB bandwidth of 100 MHz) to produce a two-photon intensity cross-correlation signal. The avalanche photodiode used was a Hamamatsu C12702-33, and the average power focused onto the detector during measurements was approximately 8 mW from each comb. The signal was electronically low-pass filtered to reject frequencies above ${f_{rep}}/2$, which removed the individual comb pulse trains from the signal, leaving only their cross-correlations. The filtered signal was acquired on a digitizer. Figure 1(c) shows an example of the signal obtained in this way. The system also included the option to simultaneously record a conventional dual-comb interferogram on an InGaAs PIN photodiode, which was supplied by light from a beamsplitter inserted immediately before the focusing lens of the silicon detector, and used a 45° polarizer to resolve a common polarization component of the probe and LO pulses.

In order to provide the first harmonic of the comb repetition rates, the outputs of both lasers were sampled independently using further InGaAs detectors. The repetition rate of the LO comb was measured using a frequency counter for use in subsequent data analysis. The repetition rate signals were mixed and low-pass filtered to obtain $\Delta {f_{rep}}$, which provided the trigger signal to the digitizer. This trigger signal was not strictly necessary but facilitated data analysis by ensuring the reference signal always appeared at the start of the digitized signal. The lasers were independently locked to stabilize $\Delta {f_{rep}}$ to a value of up to several kHz.

2.2 Comparison of dual-comb signals using conventional and two-photon detection

As discussed in Section 1, two-photon cross-correlation can facilitate metrology at update rates higher than the conventional dual-comb aliasing limit. A simple simulation illustrates the difference in the behavior of the two-photon dual-comb signal for values of $\Delta {f_{\textrm{rep}}}$ above and below the conventional aliasing limit, and provides a comparison with conventional dual-comb interferometry.

We begin by defining a Gaussian pulse with a mid-band carrier frequency of ${\omega _o}$:

$$E(t )= {e^{ - a{t^2} + i{\omega _o}t}}$$
where
$$a = \frac{{2\textrm{ln}2}}{{\Delta \tau _p^2}}$$
and $\Delta {\tau _p}$ is the full-width at half-maximum pulse duration. The spectrum of this single pulse is the Fourier transform $e(\omega )= {{\cal F}}\{{E(t )} \}$, and can be multiplied by suitable Dirac comb functions to create two frequency combs of mode spacings ${f_{rep,1}}$ and ${f_{rep,2}}$, whose fields can be represented in the time domain as:
$$\textrm{II}{\textrm{I}_{{T_1}}}(t )= {{{\cal F}}^{ - 1}}\{{e(\omega )\cdot {e^{ib{{({\omega - {\omega_o}} )}^2}/2}} \cdot \textrm{II}{\textrm{I}_{{f_{rep,1}}}}} \}$$
and
$$\textrm{II}{\textrm{I}_{{T_2}}}(t )= {{{\cal F}}^{ - 1}}\{{e(\omega )\cdot {e^{ib{{({\omega - {\omega_o}} )}^2}/2}} \cdot \textrm{II}{\textrm{I}_{{f_{rep,2}}}}} \}$$
with b representing a common amount of group delay dispersion experienced by both combs, and with pulse-repetition periods ${T_1} = 1/{f_{rep,1}}$ and ${T_2} = 1/{f_{rep,2}}$.

The conventional dual-comb interferogram is

$${g_1}(t )= {|{\textrm{II}{\textrm{I}_{{T_1}}}(t )+ \textrm{II}{\textrm{I}_{{T_2}}}(t )} |^2}$$
while the background-free two-photon dual-comb interferogram is
$${G_2}(t )= {|{\textrm{II}{\textrm{I}_{{T_1}}}(t )\cdot \textrm{II}{\textrm{I}_{{T_2}}}(t )} |^2}$$

Dual-comb signals are generated with a periodicity of $\Delta {f_{rep}} = |{{f_{rep,2}} - {f_{rep,1}}} |$ Taking pulses with transform-limited durations of 150 fs, Fig. 2 illustrates these signals for conventional interferometric detection (blue; combs combined with parallel polarizations) and background-free two-photon detection (red; combs combined with orthogonal polarizations). The left (right) column corresponds to operation at values of $\Delta {f_{rep}}$ of 0.8 ${\times} $ (4 ${\times} $) the aliasing limit. Rows one and three are the signals directly measured by an infinite-bandwidth photodetector, which resolves the individual pulses from the two combs. Rows two and four are the same detector outputs after low-pass filtering at ${f_{rep}}/2$ to remove the pulse sequences at ∼${f_{rep}}$. Below the aliasing limit, these filtered signals show well defined conventional dual-comb interferograms (Fig. 2(b)) and two-photon cross-correlations (Fig. 2(d)). Above the aliasing limit, the conventional interferograms are badly corrupted (Fig. 2(f)), while the two-photon signal is maintained at high quality (Fig. 2(h)).

 figure: Fig. 2.

Fig. 2. (a)–(d): Operation at 80% of the aliasing limit. (a) Conventional dual-comb interferometric signal before low-pass filtering and (b) after low-pass filtering at ${f_{rep}}/2$; (c) two-photon dual-comb signal before low-pass filtering and (d) after low-pass filtering at ${f_{rep}}/2$. (e)–(h): Operation at 400% of the aliasing limit, with figure descriptions otherwise the same as (a)–(d).

Download Full Size | PDF

The ability for two-photon cross-correlation to circumvent the aliasing limit may at first seem counterintuitive: the LO pulses gate the probe pulses at time intervals of $\Delta {f_{rep}}/f_{rep}^2$, which for pulse durations of $\Delta \tau $, appears to place a limit of $\Delta {f_{rep}} < f_{rep}^2\Delta \tau $ if coincidence between the pulses is to be guaranteed. For transform-limited pulses, where $\Delta \tau \Delta \nu \approx 0.5$, this temporal limit is, to a first approximation, the same as the conventional aliasing limit.

Critically, two factors extend this limit in practice. Firstly, if the pulses reaching the detector are not transform-limited then their temporal overlap is increased, and the criterion is relaxed. In the simulation presented above, group-delay dispersion was added to stretch the pulses sufficiently (still with sub-ps durations) to achieve high-quality two-photon signals. Secondly, and similar to the operation of a sampling oscilloscope, when ${f_{rep}} \ne m\Delta {f_{rep}}$ (where m is an integer) the cross-correlation trace will become better resolved with time, as eventually all possible relative delays between LO and probe pulses are sampled. These differences mean that no fundamental limit on $\Delta {f_{rep}}$ exists for static targets, although in practice trade-offs must be made between sampling-rate, precision, target motion and averaging time as the conventional aliasing limit is exceeded.

The predictions of the simulation can be compared with experiment. For our system, the 15 nm common bandwidth of the combs (see Fig. 1(d)) leads to a requirement that, to avoid aliasing artefacts, the maximum repetition rate difference should be $\Delta {f_{rep}} < $ 1.67 kHz. By contrast, the two-photon cross-correlation measurement encounters no such restriction. In Fig. 3 we present, on a common time axis, conventional and two-photon signals acquired simultaneously for values of $\Delta {f_{rep}}$ from 500 Hz–20 kHz. The corruption of the conventional dual-comb interferogram is clear to see in Figs. 3(e)–3(h), with a clearly defined envelope shape being lost entirely at the highest value of $\Delta {f_{rep}}$ and showing similarities with the simulated signals in Fig. 2(f). Conversely, the corresponding two-photon cross-correlation signal remains clearly distinguishable for all values of $\Delta {f_{rep}}$. As can be seen from Fig. 3(p), even sampling at $\Delta {f_{rep}} = $ 20 kHz, corresponding to 12× the conventional aliasing limit, yields a clear two-photon cross-correlation signal on an oscilloscope. Comparing Figs. 3(i)–3(p) illustrates how the width of the signal scales inversely with $\Delta {f_{rep}}$, since dual-comb techniques scale optical time into laboratory time by a factor of ${f_{rep}}/\Delta {f_{rep}}$.

 figure: Fig. 3.

Fig. 3. (a)–(h): Conventional dual-comb interferograms collected for $\Delta {f_{rep}}$ values of 500 Hz, 1.0 kHz, 1.5 kHz, 2.0 kHz, 4.0 kHz, 8.0 kHz, 15.0 kHz and 20.0 kHz respectively. (i)–(p): Two-photon cross-correlation signals acquired simultaneously with the interferograms in (a)–(h). All data were acquired at a sampling rate of 200 MSa/s.

Download Full Size | PDF

2.3 Demonstration of time-of-flight ranging using two-photon detection

We evaluated the performance of dual-comb ranging using the target-reference mirror scheme shown in Fig. 1 and with a roundtrip target-reference path difference of 24 cm. The repetition rate difference was set to $\Delta {f_{rep}} = $ 4 kHz, corresponding to 2.4${\times} $ the conventional aliasing limit. The two-photon cross-correlation signals were acquired on a GaGe Razormax digitizer, and an example of a short section of one dataset is shown in Fig. 4(a), with the more intense signals being from the target ($T$) mirror and the weaker signals from the reference ($R$) mirror. With reference to Fig. 4(a), the time-of-flight path difference for measurement i is calculated as ${v_g}t_i^{TR}/({t_i^{TR} + t_i^{RT}} )\; {f_{rep({\textrm{LO}} )}}$, where the signal period is $t_i^{TR} + t_i^{RT} = 1/\Delta {f_{rep}}$. The Allan deviation of the distance measurement is shown in Fig. 4(b) for averaging times of up to two seconds. For the minimum acquisition time of 250 μs (set by the 4 kHz difference in the repetition rates) the measurement precision is 17.8 μm. As the fitted $\surd \tau $ line shows, the precision scales as the square root of the number of samples, reaching sub-µm precision for 0.1 s of averaging. After 1 s of averaging, the precision reaches 150 nm ($\lambda /10)$, falling to 93 nm after 2 s of averaging, which is below the 10−7 uncertainty limit imposed by atmospheric fluctuations. This performance is comparable with previously published results from conventional dual-comb distance metrology, which achieve few-µm precisions in around 1 ms averaging times [2,3,9,10,11].

 figure: Fig. 4.

Fig. 4. (a) Two-photon dual-comb cross-correlations between the local oscillator and the target ($T$) and reference ($R$) reflections, recorded over a time of nearly two measurement periods ($2/\Delta {f_{rep}}$). The notation defines $t_i^{TR}$ as the time delay of the ${i^{th}}$ LO-reference cross-correlation after the previous LO-target cross-correlation, and $t_i^{RT}$ as the delay of the ${i^{th}}$ LO-target cross-correlation after the previous LO-reference cross-correlation. (b) Analysis of the digitizer dataset containing the measurements presented in (a), showing an Allan deviation with an instantaneous precision of 17.8 μm, falling to 150 nm for 1s of averaging. The dashed red line has a slope of -0.5.

Download Full Size | PDF

3. Extension to two-photon dual-comb LiDAR

In conventional LiDAR, the time-of-flight of a tens-of-nanosecond pulse reflected from a target is measured directly using electronics with sub-100 ps timing resolution, equating to few-cm precision. The digital character of the two-photon cross-correlation signals allows them to be used in a similar way, but with the important distinction that the true time-of-flight is magnified by a factor of ${f_{rep}}/\Delta {f_{rep}}$ – a value of between 20,000 and 400,000 in our system. Even using timing electronics with only modest resolution, this magnification factor allows few-µm precision to be achieved directly from dynamic timing signals, circumventing the extreme data burden which can be encountered in dual-comb techniques which digitize the full interferometric signal.

In a proof-of-concept experiment, we used a simple microcontroller as a ns-precision stopwatch to record the time intervals separating the cross-correlations between the LO pulses and successive target and reference pulses. The microcontroller was operated with a clock frequency of 600 MHz (cycle period 1.67 ns), and was configured to continuously count clock cycles in an onboard register. A rising edge presented on one of the pins triggered an interrupt which reset the cycle count and wrote the previous total count to a serial interface for use by other software.

We conditioned the two-photon cross-correlation pulses from their raw 10 mV peak-peak format by first amplifying them to around 500 mV peak-peak using an inverting RF amplifier (Figs. 5(a) and 5(b)), following which further amplification and a two-stage Schmitt trigger were used to provide clean 3.3 V pulses suitable for triggering the microcontroller (Fig. 5(c)).

 figure: Fig. 5.

Fig. 5. (a) Oscilloscope images showing pairs of two-photon cross-correlations between the LO pulses and successive target / reference pulses after first-stage amplification, and (b) a single pair of target / reference cross-correlations. (c) Example of a single cross-correlation after the Schmitt trigger circuit. After attenuation this was used as the input to the microprocessor.

Download Full Size | PDF

The resulting signal comprised pairs of short electrical pulses, with one pulse in each pair encoding the target reflection ($T$) and the other pulse encoding the reference reflection ($R$). With reference to the notation in Fig. 4, the time intervals between the pairs of pulses can be denoted as, $t_i^{TR}$ and $t_i^{RT}$. The counter, which increments once every microcontroller clock period (${\tau _{CPU}}$), is reset by the arrival of each pulse. When a reset occurs, the microcontroller sends the previous counter value to the serial bus, and in this way a series of alternating numbers is recorded, $n_i^{TR} = t_i^{TR}/{\tau _{CPU}}$ and $n_i^{RT} = t_i^{RT}/{\tau _{CPU}}$, which can be used to obtain the instantaneous absolute distance using the probe-laser pulse repetition frequency, ${f_{rep}}$, according to:

$${d_i} = \frac{{{v_g}}}{{2{f_{rep}}}} \cdot \frac{{n_i^{TR}}}{{n_i^{TR} + n_i^{RT}}}.$$

The instantaneous repetition rate difference between the combs is similarly available from the timing signals using:

$$\Delta {f_{rep,i}} = \frac{1}{{{\tau _{CPU}}({n_i^{TR} + n_i^{RT}} )}}.$$

The time ${t_j}$ at which distance ${d_j}$ is measured is computed from the counter values:

$${t_j} = \mathop \sum \limits_1^j {\tau _{CPU}}({n_i^{TR} + n_i^{RT}} )$$

Extracting the lab time in this way makes the measurement insensitive to changes in the repetition rate difference between the lasers, allowing for accurate measurements of dynamic changes in an object's position.

An illustration of the approach is shown in Fig. 6. Data in Figs. 6(a)–6(c) were obtained with static target and reference mirrors when the combs were locked with $\Delta {f_{rep}} = $ 2430 Hz. The dataset length of around 25 seconds occupied only a few 100 kB, corresponding to many orders of magnitude less than the equivalent for digitizer-based measurements. Figure 6(a) shows the CPU cycle counts recorded, and the inset (1 ms/div scale) illustrates the recorded data points. A distance of 47.832 mm was inferred using Eq. (7) and its real-time measurement is shown in Fig. 6(b). The peaks in Fig. 6(b) correspond to timing errors of up to 25 CPU cycles (42 ns), which could result from latency in the microcontroller or switching glitches in the Schmitt trigger. The data have a standard deviation of ${\pm} $12 µm, broadly matching the distance uncertainty determined by one clock cycle of ${v_g}{\tau _{CPU}}\Delta {f_{rep}}/{f_{rep}}$. By using Eq. (8) the instantaneous value of $\Delta {f_{rep}}$ can be determined. Since for this measurement the comb repetition rates were both locked, the obtained value of $\Delta {f_{rep}}$ is almost constant at 2430 Hz, however small exponentially-decaying oscillations can be seen (Fig. 6(c), arrows) that reveal the comb locking electronics responding to environmental perturbations. Finally, in Fig. 6(d) we show a series of distance measurements, where a mirror mounted on a loudspeaker was driven sinusoidally at 2 Hz for increasing amplitudes. Data are shown for loudspeaker amplitudes of up to 375 µm and are each offset vertically by 1 mm for clarity.

 figure: Fig. 6.

Fig. 6. (a) Counted cycles over a 25 second interval. The inset shows, respectively, the counts $n_i^{RT}$ and $n_i^{TR}$ over a 10 ms interval. (b) The absolute distance, extracted using Eq. (7). (c) The instantaneous value of the repetition rate difference, $\Delta {f_{rep,i}}$, computed from Eq. (8) and shown on a timebase derived using Eq. (9). The arrows indicate small changes in $\Delta {f_{rep}}$ caused by environmental perturbations to one comb, and the consequent reaction of the locking electronics, which leads to a damped oscillation that restores the comb to the locked condition. (d) Dual-comb LiDAR measurement of a 2 Hz sinusoidally scanning mirror. Multiple datasets were recorded for increasing mirror amplitudes and are shown with a vertical offset of 1 mm. The measurement for zero amplitude lies under the time axis.

Download Full Size | PDF

We assessed the precision of the absolute distance measurement obtained using this timer-based approach using an Allan deviation analysis, shown in Fig. 7, of the distance recorded for a static target mirror. The data, again recorded with $\Delta {f_{rep}} = $ 2430 Hz, show similar precisions to those obtained using full digitizer-based sampling, achieving sub-µm precision in 50 ms, and sub-100 nm precision in around 3 s.

 figure: Fig. 7.

Fig. 7. Allan deviation of the absolute distance measurements obtained from approximately 20 seconds of data. The distance is calculated using Eq. (7) from a continuous stream of cycle counts provided by the microcontroller. The dashed red line has a slope of -0.5.

Download Full Size | PDF

By using dedicated time-of-flight electronics we expect to be able to further improve the precision, and eliminate spurious distance values. Commercially available time-of-flight modules can achieve a timing resolution of 55 ps [19], which for $\Delta {f_{rep}} = $ 2430 Hz and ${f_{rep}} \approx $ 78 MHz implies a timing-limited distance precision of 250 nm.

While not all applications requiring high-speed, high-precision absolute distance measurements necessitate eye-safe power levels, we consider here the compatibility of the system with eye-safety constraints. Treating the lasers as cw 1560-nm sources because of their high repetition rates, American National Standard ANSI Z136.6-2005 permits a maximum permissible exposure (MPE) of 100 mW cm-2. Two-photon detection was possible with only 1.23 mW (per beam) incident on the detector, corresponding to attenuating the probe laser beam to 6 mW. At the MPE limit, this implies a minimum FWHM beam diameter of 2.3 mm, a criterion which is already easily satisfied by the beam sizes in our current system. Although the results presented here were obtained with higher powers, operation within eye-safety limits is entirely realistic.

4. Conclusions

Two-photon dual-comb cross-correlation time-of-flight metrology shows considerable potential for dynamic, absolute distance measurements. The non-interferometric nature of the measurement is unconstrained by the conventional dual-comb aliasing limit, allowing operation at considerably higher acquisition rates than interferometric dual-comb metrology. Polarization, wavelength and ${f_{CEO}}$ stability constraints on the lasers are considerably relaxed or removed entirely, while two-photon detection suppresses any contributions to the signal from ambient light or amplified spontaneous emission. The short, transient character of the two-photon signal is well suited to LiDAR-type timer-based detection, removing the vast data overhead normally associated with dual-comb techniques and allowing for dynamic and continuous absolute distance monitoring at few-µm, and potentially sub-µm resolution.

Funding

Renishaw plc; Engineering and Physical Sciences Research Council (EP/L01596X/1, EP/N002547/1).

Acknowledgement

We are grateful to Prof. Ron Hui and his group at the University of Kansas for early influential discussions on the Er:fiber laser design. We would like to thank Michael Erasmus for his assistance in creating Fig. 1(b).

Disclosures

The authors declare no conflicts of interest.

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

References

1. I Coddington, W C Swann, L Nenadovic, and N R Newbury, “Rapid and precise absolute distance measurements at long range,” Nat. Photonics 3(6), 351–356 (2009). [CrossRef]  

2. T-A Liu, N R Newbury, and I Coddington, “Sub-micron absolute distance measurements in sub-millisecond times with dual free-running femtosecond Er fiber-lasers,” Opt. Express 19(19), 18501–18509 (2011). [CrossRef]  

3. T-A Liu, Y-C Chuang, H-W Lee, P-E Hsu, and J-L Peng, “Large non-ambiguity range and precise absolute distance measurement with dual mode-locked fiber lasers,” Appl. Mech. Mater. 764-765, 1314–1318 (2015). [CrossRef]  

4. D Hu, Z Wu, H Cao, Y Shi, R Li, H Tian, Y Song, and M Hu, “Dual-comb absolute distance measurement of non-cooperative targets with a single free-running mode-locked fiber laser,” Opt. Commun. 482, 126566 (2021). [CrossRef]  

5. J Nürnberg, B Willenberg, C R Phillips, and U Keller, “Dual-comb ranging with frequency combs from single cavity free-running laser oscillators,” Opt. Express 29(16), 24910–24918 (2021). [CrossRef]  

6. T W Hänsch, “Nobel lecture: Passion for precision,” Rev. Mod. Phys. 78(4), 1297–1309 (2006). [CrossRef]  

7. J L Hall, “Nobel lecture: Defining and measuring optical frequencies,” Rev. Mod. Phys. 78(4), 1279–1295 (2006). [CrossRef]  

8. H R Telle, G Steinmeyer, A E Dunlop, J Stenger, D H Sutter, and U Keller, “Carrier-envelope offset phase control: A novel concept for absolute optical frequency measurement and ultrashort pulse generation,” Appl. Phys. B 69(4), 327–332 (1999). [CrossRef]  

9. H Zhang, H Wei, X Wu, H Yang, and Y Li, “Absolute distance measurement by dual-comb nonlinear asynchronous optical sampling,” Opt. Express 22(6), 6597–6604 (2014). [CrossRef]  

10. H Shi, Y Song, F Liang, L Xu, M Hu, and C Wang, “Dual-comb absolute ranging using balanced optical cross-correlator as time-of-flight detector,” In CLEO: Science and Innovations, pages SF2L-3. Optical Society of America, 2015.

11. S Han, Y-J Kim, and S-W Kim, “Parallel determination of absolute distances to multiple targets by time-of-flight measurement using femtosecond light pulses,” Opt. Express 23(20), 25874–25882 (2015). [CrossRef]  

12. D T Reid, M Padgett, C McGowan, W E Sleat, and W Sibbett, “Light-emitting diodes as measurement devices for femtosecond laser pulses,” Opt. Lett. 22(4), 233–235 (1997). [CrossRef]  

13. J M Dudley, D T Reid, W Sibbett, L P Barry, B Thomsen, and J D Harvey, “Commercial Semiconductor Devices for Two Photon Absorption Autocorrelation of Ultrashort Light Pulses,” Appl. Opt. 37(34), 8142–8144 (1998). [CrossRef]  

14. J-C M Diels, J J Fontaine, I C McMichael, and F Simoni, “Control and measurement of ultrashort pulse shapes (in amplitude and phase) with femtosecond accuracy,” Appl. Opt. 24(9), 1270–1282 (1985). [CrossRef]  

15. L C Sinclair, I Coddington, W C Swann, G B Rieker, A Hati, K Iwakuni, and N R Newbury, “Operation of an optically coherent frequency comb outside the metrology lab,” Opt. Express 22(6), 6996–7006 (2014). [CrossRef]  

16. L C Sinclair, J-D Deschenes, L Sonderhouse, W C Swann, I H Khader, E Baumann, N R Newbury, and I Coddington, “Invited article: A compact optically coherent fiber frequency comb,” Rev. Sci. Instrum. 86(8), 081301 (2015). [CrossRef]  

17. G. Vedala and R. Hui, “Auto-Start Mechanism of a Polarization-Multiplexed Dual-Frequency Femtosecond Fiber Laser,” in Conference on Lasers and Electro-Optics, OSA Technical Digest (online) (Optical Society of America, 2018), paper JW2A.147.

18. R. Hui, “Absorption spectroscopy based on polarization-multiplexed dual-frequency femtosecond fiber laser combs,” in Conference on Lasers and Electro-Optics, OSA Technical Digest (online) (Optical Society of America, 2017), paper AF1B.2.

19. An example of a dedicated time-of-flight measurement module is the Texas Instruments TDC7200 (https://www.ti.com/product/TDC7200), which achieves 55-ps resolution with a standard deviation of 35 ps.

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (7)

Fig. 1.
Fig. 1. (a) Design of the Er:fiber laser combs, in which a low-power master oscillator is free-space coupled into a two-stage amplifier with total gain of 16.5 dB. One comb was constructed to exactly this design, while the other was identical except for the use of a fiber-butt-coupled SESAM instead of free-space coupling. WDM: wavelength division multiplexer; PBS: polarizing beamsplitter; OC: output coupler. (b) Dual-comb two-photon-absorption (TPA) detection scheme. BS: non-polarizing beamsplitter; D: silicon avalanche photodetector; LPF: long-pass filter ($\lambda > $1300 nm). (c) Representative two-photon cross-correlation signal. (d) Optical spectra of the probe (blue) and LO combs (red).
Fig. 2.
Fig. 2. (a)–(d): Operation at 80% of the aliasing limit. (a) Conventional dual-comb interferometric signal before low-pass filtering and (b) after low-pass filtering at ${f_{rep}}/2$; (c) two-photon dual-comb signal before low-pass filtering and (d) after low-pass filtering at ${f_{rep}}/2$. (e)–(h): Operation at 400% of the aliasing limit, with figure descriptions otherwise the same as (a)–(d).
Fig. 3.
Fig. 3. (a)–(h): Conventional dual-comb interferograms collected for $\Delta {f_{rep}}$ values of 500 Hz, 1.0 kHz, 1.5 kHz, 2.0 kHz, 4.0 kHz, 8.0 kHz, 15.0 kHz and 20.0 kHz respectively. (i)–(p): Two-photon cross-correlation signals acquired simultaneously with the interferograms in (a)–(h). All data were acquired at a sampling rate of 200 MSa/s.
Fig. 4.
Fig. 4. (a) Two-photon dual-comb cross-correlations between the local oscillator and the target ($T$) and reference ($R$) reflections, recorded over a time of nearly two measurement periods ($2/\Delta {f_{rep}}$). The notation defines $t_i^{TR}$ as the time delay of the ${i^{th}}$ LO-reference cross-correlation after the previous LO-target cross-correlation, and $t_i^{RT}$ as the delay of the ${i^{th}}$ LO-target cross-correlation after the previous LO-reference cross-correlation. (b) Analysis of the digitizer dataset containing the measurements presented in (a), showing an Allan deviation with an instantaneous precision of 17.8 μm, falling to 150 nm for 1s of averaging. The dashed red line has a slope of -0.5.
Fig. 5.
Fig. 5. (a) Oscilloscope images showing pairs of two-photon cross-correlations between the LO pulses and successive target / reference pulses after first-stage amplification, and (b) a single pair of target / reference cross-correlations. (c) Example of a single cross-correlation after the Schmitt trigger circuit. After attenuation this was used as the input to the microprocessor.
Fig. 6.
Fig. 6. (a) Counted cycles over a 25 second interval. The inset shows, respectively, the counts $n_i^{RT}$ and $n_i^{TR}$ over a 10 ms interval. (b) The absolute distance, extracted using Eq. (7). (c) The instantaneous value of the repetition rate difference, $\Delta {f_{rep,i}}$, computed from Eq. (8) and shown on a timebase derived using Eq. (9). The arrows indicate small changes in $\Delta {f_{rep}}$ caused by environmental perturbations to one comb, and the consequent reaction of the locking electronics, which leads to a damped oscillation that restores the comb to the locked condition. (d) Dual-comb LiDAR measurement of a 2 Hz sinusoidally scanning mirror. Multiple datasets were recorded for increasing mirror amplitudes and are shown with a vertical offset of 1 mm. The measurement for zero amplitude lies under the time axis.
Fig. 7.
Fig. 7. Allan deviation of the absolute distance measurements obtained from approximately 20 seconds of data. The distance is calculated using Eq. (7) from a continuous stream of cycle counts provided by the microcontroller. The dashed red line has a slope of -0.5.

Equations (9)

Equations on this page are rendered with MathJax. Learn more.

E ( t ) = e a t 2 + i ω o t
a = 2 ln 2 Δ τ p 2
II I T 1 ( t ) = F 1 { e ( ω ) e i b ( ω ω o ) 2 / 2 II I f r e p , 1 }
II I T 2 ( t ) = F 1 { e ( ω ) e i b ( ω ω o ) 2 / 2 II I f r e p , 2 }
g 1 ( t ) = | II I T 1 ( t ) + II I T 2 ( t ) | 2
G 2 ( t ) = | II I T 1 ( t ) II I T 2 ( t ) | 2
d i = v g 2 f r e p n i T R n i T R + n i R T .
Δ f r e p , i = 1 τ C P U ( n i T R + n i R T ) .
t j = 1 j τ C P U ( n i T R + n i R T )
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.