Abstract
The use of X-rays for gas discharge laser preionization offers the following potential advantages:
(i) a cleaner, higher penetration source of preionization electrons than that provided hy corona or uv spark sources, (ii) a more rugged, higher repetition rate source than electron beam preionization.
© 1982 Optical Society of America
PDF ArticleMore Like This
M. R. Osborne, M. H. R. Hutchinson, and Peter W. Smith
THP4 Conference on Lasers and Electro-Optics (CLEO:S&I) 1984
L. F. Champagne, A. J. Dudas, and B. L. Wexler
ThR8 Conference on Lasers and Electro-Optics (CLEO:S&I) 1984
S. BOLLANTI, P. Di LAZZARO, F. FLORA, I. GIAB-BAI, G. GIORDANO, T. LETARDI, and C. E. ZHENG
TUM17 Conference on Lasers and Electro-Optics (CLEO:S&I) 1988