Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Impinged Droplet Evaporative Cooling for Optical Mirrors Subjected to High Thermal Flux Loads

Open Access Open Access

Abstract

Utilization of evaporative cooling for optical mirrors subjected to high thermal flux loads has been investigated. Analytical and experimental results show advantages over convective cooling.

© 1987 Optical Society of America

PDF Article
More Like This
Integrated-Flow Active Cooling for the Thermal Management of Reflective Optics Under High-Average-Power Load

E. P. Power, J. Bromage, and J. D. Zuegel
SW4E.2 CLEO: Science and Innovations (CLEO:S&I) 2020

Direct Simulation of Evaporative Cooling

Huang Wu and Christopher J. Foot
QTuG4 European Quantum Electronics Conference (EQEC) 1996

Evaporative cooling in optical dipole traps

R. Grimm, M. Hammes, D. Rychtarik, T. Weber, J. Herbig, H.-C. Nägerl, M. Mudrich, S. Kraft, K. Singer, A. Mosk, and M. Weidemüller
QFA1 Quantum Electronics and Laser Science Conference (CLEO:FS) 2001