Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

High Repetition Rate Production of Picosecond Pulses at Wavelengths <250nm

Not Accessible

Your library or personal account may give you access

Abstract

In this paper we describe a laser system for generating picosecond pulses with wavelengths <250nm at a 5kHz repetition rate. Short pulses from a synchronously-pumped dye laser are amplified to a peak power >5MW in a dye medium pumped by a copper vapor laser. Nonlinear optical techniques can then be used to shift the wavelength well into the UV. The high repetition rate of the pulses is important for pump-probe picosecond spectroscopy. Other laser systems have generally fallen into one of two groups: one with large pulse energies at low repetition rates (>1MW at <100Hz) and one using very small pulses at high repetition rates ( < 3kW at >50MHz). The large pulse experiments can create a transient population large enough to change the sample absorbance considerably, but often unwanted nonlinear effects accompany the extremely high intensities created by squeezing a large number of photons into a pulse of few picoseconds duration. Lower intensities necessitate sensitive probing of the transient population with careful signal averaging. This need has led several research groups to develop the high repetition rate systems using lock-in amplifiers and/or extremely high frequency modulation with AM radio detection [1-6]. The low powers of the high repetition rate systems severely limits the use of nonlinear optical techniques needed to obtain picosecond pulses with UV and VUV wavelengths. Tunable pulses with peak powers of greater than 1MW have been available for several years using Nd:YAG laser pumped amplifiers at 10 Hz repetition [7–10] and more recently at 100Hz using excimer laser pumped amplifiers [11]. In the system to be described here the amplified pulses provide the fundamental wavelength for second harmonic generation and for sum-frequency mixing to generate the third harmonic. Stimulated Raman shifting in liquids is also posible for the generation of probe wavelengths.

© 1984 Optical Society of America

PDF Article
More Like This
Simple, inexpensive, high-repetition-rate tunable picosecond dye laser

V. Masilamani, L. Pozzi, and F. Docchio
TUB29 Conference on Lasers and Electro-Optics (CLEO:S&I) 1984

High repetition rate picosecond x-ray source

T. Anderson, I. V. Tomov, and P. M. Rentzepis
MP5 OSA Annual Meeting (FIO) 1992

Self-sustained Picosecond Pulse Generation in a GaAlAs Laser at an Electrically Tunable Repetition Rate

K.Y. Lau and A. Yariv
WB3 Integrated and Guided Wave Optics (IGWO) 1984

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.