Simple and Precise Characterization of Full-Field Frequency Response for Coherent TOSA

Not Accessible

Your library or personal account may give you access

Abstract

The performance of high baud-rate fiber optical transmission with the use of advanced modulation formats is sensitive to the imperfection arising in transmitter optical sub-assembly (TOSA), and thus the effective calibration of the TOSA full-field response is essential. However, traditional TOSA frequency response characterization solutions are either inconvenient for the on-field measurement or unable to obtain the phase frequency response (PFR). Here, we report a simple and precise scheme to characterize the full-field frequency response of broadband TOSA, including both amplitude frequency response (AFR) and PFR, when only a single photodetector (PD) with narrow bandwidth is employed. A multiple dual-tone signals with specially designed frequency positions are implemented for electrical-to-optical modulation. Then, a few beat signals after direct detection occur at unique frequencies without the spectral overlapping. Thus, it is feasible to extract the full-field frequency response of broadband TOSA, under the single-shot measurement. Moreover, the in-phase and quadrature (IQ) skew can be obtained by comparing PFRs between I and Q tributaries. In the experiment, we successfully characterize a coherent TOSA with a 10 dB bandwidth of 40 GHz, when a single PD with a 3 dB bandwidth of 2 GHz is used. In comparison with the optical spectrum analyzer (OSA) based scheme, the measured AFR deviation is less than 1 dB over the 10 dB bandwidth. When multiple single-shot measurements are implemented within 1 minute, the fluctuation of measured PFR and IQ skew are less than 0.2 rad and 1 ps, respectively. With the help of the measured full-field frequency response, the coherent TOSA can be calibrated to realize 64 GBaud 16-quadrature amplitude modulation (QAM) back-to-back transmission, when the threshold of 7% hard-decision forward error correction (HD-FEC) is set.

PDF Article

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.