Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Development of a large-field streak tube for underwater imaging lidar

Not Accessible

Your library or personal account may give you access

Abstract

Streak tube imaging lidar (STIL) can obtain 4-D images of a target, and its performance is mainly determined by the streak tube sensor. To obtain a large field of view, we developed a streak tube with a photocathode length as large as 35.3 mm, which is larger than the commonly used ST-HDR (30 mm). At the same time, the temporal resolution and dynamic spatial resolution are 60 ps and 12 lp/mm, which are very suitable to obtain accurate target coordinates for 4-D imaging. In addition, the streak tube has a high detection sensitivity of 46 mA/W at 500 nm and, hence, prospects in remote imaging. To test the performance of the streak tube, an underwater STIL experiment was conducted. Echo signal processing was performed by means of a bandpass filter and a matched filter, and then the peak detection algorithm was used to reconstruct the image. The results indicate that a spatial resolution better than 9 mm is achieved in the limpid water with a depth of 20 m, and a range accuracy of 1 cm is achieved in the turbid water with a depth of 10 m. Such a performance suggests that the large-field streak tube is of great potential for underwater target imaging and other remote imaging applications.

© 2022 Optica Publishing Group

Full Article  |  PDF Article
More Like This
Design and modeling of three-dimensional laser imaging system based on streak tube

Wenze Xia, Shaokun Han, Naeem Ullah, Jingya Cao, Liang Wang, Jie Cao, Yang Cheng, and Haoyong Yu
Appl. Opt. 56(3) 487-497 (2017)

Target classification of multislit streak tube imaging lidar based on deep learning

Wenhao Li, Shangwei Guo, Yu Zhai, Fei Liu, Zhengchao Lai, and Shaokun Han
Appl. Opt. 60(28) 8809-8817 (2021)

Signal-to-noise performance analysis of streak tube imaging lidar systems. I. Cascaded model

Hongru Yang, Lei Wu, Xiaopeng Wang, Chao Chen, Bing Yu, Bin Yang, Liang Yuan, Lipeng Wu, Zhanli Xue, Gaoping Li, and Baoning Wu
Appl. Opt. 51(36) 8825-8835 (2012)

Data availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request.

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (9)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (2)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (8)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.