Evaluation of Ethene Addition to the Nebulizer Gas in Inductively Coupled Plasma-Mass Spectrometry for the Removal of Matrix-, Solvent-, and Support-Gas-Derived Polyatomic Ion Interferences

Not Accessible

Your library or personal account may give you access

Abstract

Ethene addition to the nebulizer gas is assessed as a means of reducing the levels of polyatomic ions in ICP-MS. It was found that, while the absolute analyte response was generally poorer with the addition of ethene, the levels of the interferences were greatly reduced, when compared to the all argon plasma. The plasma operating conditions, with the addition of ethene to the nebulizer gas, were optimized with the use of a variable-step-size Simplex procedure in order to remove or reduce the ArO<sup>+</sup>, ArCl<sup>+</sup>, ClO<sup>+</sup>, CeO<sup>+</sup>, ArNa<sup>+</sup>, SO<sub>2</sub><sup>+</sup>/S<sub>2</sub><sup>+</sup>, and PO<sub>2</sub><sup>+</sup>, interferences. Complete removal of the ArCl<sup>+</sup>, ArNa<sup>+</sup>, SO<sub>2</sub><sup>+</sup>/S<sub>2</sub><sup>+</sup>, and PO<sub>2</sub><sup>+</sup> was achieved, while the levels of the remaining interferences were very much reduced. Detection limits for As, Se, and V in 10% HCl were excellent (0.27, 2.7, and 2.04 ng cm<sup>-3</sup>, respectively), as was the detection limit for Cu in 1% H<sub>3</sub>PO<sub>4</sub> at 6.9 ng cm<sup>-3</sup>. Cu, Ni, and Zn detection limits in the presence of H<sub>2</sub>SO<sub>4</sub> and sodium ions were also improved, and the detection limit for Fe was 0.48 ng cm<sup>-3</sup>. Levels of CeO<sup>+</sup> were reduced to just 0.2% relative to Ce. Recovery tests and the analysis of certified reference materials further demonstrated the utility of the optimal conditions. A set of compromise ethene conditions was identified and shown to be of value in reducing the interferences simultaneously.

PDF Article
More Like This
Multielemental analysis of prehistoric animal teeth by laser-induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry

Michaela Galiová, Jozef Kaiser, Francisco J. Fortes, Karel Novotný, Radomír Malina, Lubomír Prokeš, Aleš Hrdlička, Tomáš Vaculovič, Miriam Nývltová Fišáková, Jiří Svoboda, Viktor Kanický, and Javier J. Laserna
Appl. Opt. 49(13) C191-C199 (2010)

Detection of trace elements in liquids by laser-induced breakdown spectroscopy with a Meinhard nebulizer

Akshaya Kumar, Fang Y. Yueh, Tracy Miller, and Jagdish P. Singh
Appl. Opt. 42(30) 6040-6046 (2003)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.