Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of Lightwave Technology
  • Vol. 38,
  • Issue 22,
  • pp. 6412-6421
  • (2020)

Simultaneous Measurement of Pressure and Temperature in Seawater with PDMS Sealed Microfiber Mach-Zehnder Interferometer

Not Accessible

Your library or personal account may give you access

Abstract

Simultaneous measurement of pressure and temperature in seawater is realized based on polydimethylsiloxane (PDMS) sealed microfiber Mach–Zehnder interferometer (MZI). Benefitting from the high thermal-optic coefficient and large elasticity of PDMS, high sensitivity and robust structure can be obtained. In theoretical modeling, significant enhanced pressure response in fiber is observed clearly, and pressure or temperature sensitivities are calculated theoretically. In experiment, PDMS sealed MZI is fabricated by a two-step sealing method. Using this MZI, sensitivity of 13.31 nm/MPa for pressure sensing and −7.41 nm/°C for temperature sensing are demonstrated, respectively, which are about one order higher than bare fiber MZIs (without PDMS sealing). To verify the accuracy of sensor, several tests under arbitrarily pressure and temperature are performed with average errors of 4.38% and 1.44%, respectively. In addition, effects of encapsulation on avoiding cross-sensitivity with salinity, PDMS thickness on pressure sensitivity, response time, repeatability, time stability, and polarization of the sensor are also evaluated by experiment. Sensors demonstrated here show advantages of low cost, simple fabrication, robust and compact structure, high-pressure resistance, high sensitivity, good repeatability, and long-term stability.

PDF Article
More Like This
Splicing point tapered fiber Mach-Zehnder interferometer for simultaneous measurement of temperature and salinity in seawater

Tianqi Liu, Jing Wang, Yipeng Liao, Lei Yang, and Shanshan Wang
Opt. Express 27(17) 23905-23918 (2019)

All-fiber Mach–Zehnder interferometer for tunable two quasi-continuous points’ temperature sensing in seawater

Tianqi Liu, Jing Wang, Yipeng Liao, Xin Wang, and Shanshan Wang
Opt. Express 26(9) 12277-12290 (2018)

Ultrasensitive measurement of tactile force based on a PDMS-embedded microfiber Mach-Zehnder interferometer

Lijun Li, Tianzong Xu, Qian Ma, Jie Wang, Mengge Xue, Fan Yang, and Zheng Lin
Opt. Express 32(3) 3251-3265 (2024)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.