Current-Modulated Cavity Ring-Down Spectroscopy for Mobile Monitoring of Natural Gas Leaks

Not Accessible

Your library or personal account may give you access

Abstract

An improved current-modulated cavity ring-down spectroscopy(CRDS) approach is proposed and the experimental results reported in this article. The step-wise fine current modulation is imposed on the laser driving direct current (DC) component and achieves a proper wavelength matching between the incident laser beam and the resonating ringing cavity, which is then turned off to stop the laser injection. The feedback of this modulation at this matching point is used not only to monitor the status of the whole building-up process, but also to increase the measurement rate. The device exhibits a detection limit of 0.8 ppbv for CH4 in a 60 second averaging period and a detection limit of 10 ppbv for C2H6 in a 16 second averaging period. In the natural gas leak field test based on a vehicle platform, the background methane concentration in the atmosphere was measured to be 1.95 ppmv with a sensitivity of 18.2 ppbv; while the background ethane concentration of 0.0787 ppmv and sensitivity of 31.2 ppbv was recorded. A typical natural gas pipeline inspection process is introduced and performed in the field test in Beijing. A leakage found during the field test has been repaired by the gas company.

PDF Article
More Like This
Open-path cavity ring-down methane sensor for mobile monitoring of natural gas emissions

Laura E. Mchale, Benjamin Martinez, Thomas W. Miller, and Azer P. Yalin
Opt. Express 27(14) 20084-20097 (2019)

Multicomponent gas detection based on concise CW-cavity ring-down spectroscopy with a bow-tie design

Jinduo Wang, Jin Yu, Zeqiang Mo, Jianguo He, Shoujun Dai, Jingjing Meng, Yang Liu, Xue Zhang, and Hong Yi
Appl. Opt. 58(11) 2773-2781 (2019)

Ultra-sensitive ethylene post-harvest monitor based on cavity ring-down spectroscopy

Edward H. Wahl, Sze M. Tan, Sergei Koulikov, Boris Kharlamov, Christopher R. Rella, Eric R. Crosson, Dave Biswell, and Barbara A. Paldus
Opt. Express 14(4) 1673-1684 (2006)