Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of Lightwave Technology
  • Vol. 40,
  • Issue 9,
  • pp. 3090-3097
  • (2022)

Experimental Study on Dual-Parameter Sensing Based on Cascaded Sagnac Interferometers With Two PANDA Fibers

Not Accessible

Your library or personal account may give you access

Abstract

A sensitivity-amplifying optical fiber sensor using cascaded Sagnac interferometers (CSIs) was designed and experimentally demonstrated for the dual-parameter measurement of strain and temperature. The proposed CSIs sensor consisted of two Sagnac interferometers (SIs) in which two identical PANDA polarization-maintaining fibers (PMFs) for just slightly different lengths were inserted. An envelope with a period of 123.6 nm, which was amplified more than 10 times than the single SI, was observed in the interference spectrum. Experimental results showed that the strain sensitivity increased from 32.91 pm/με for the single SI to 336 pm/με for the CSIs, while the temperature sensitivity increased from −1.38 nm/°C for the single SI to −14.86 nm/°C for the CSIs, correspondingly. We also found that the envelope of the CSIs shifted in opposite directions when the longer or shorter PMF was selected as the sensing arm. Higher sensitivity could be realized by selecting longer PMF as the sensing arm. Our proposed CSIs sensor possesses the merits of simple structure, high sensitivity, low cost, and low hysteresis effect, which make it a competitive candidate for strain and temperature monitoring.

PDF Article
More Like This
Cascaded interferometers structure based on dual-pass Mach–Zehnder interferometer and Sagnac interferometer for dual-parameter sensing

Shun Wang, Ping Lu, Lili Mao, Deming Liu, and Shibin Jiang
Opt. Express 23(2) 674-680 (2015)

Ultrasensitive temperature sensor with Vernier-effect improved fiber Michelson interferometer

Yuanfang Zhao, Maolin Dai, Zhenmin Chen, Xuanyi Liu, M. S. Aruna Gandhi, Qian Li, and H. Y. Fu
Opt. Express 29(2) 1090-1101 (2021)

Vernier effect assisted sucrose sensor based on a cascaded Sagnac interferometer with no-core fiber

Yuanfang Zhao, Manthangal Sivanesan Aruna Gandhi, Qian Li, Zhengyong Liu, and H. Y. Fu
Biomed. Opt. Express 12(12) 7338-7347 (2021)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.