Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of Near Infrared Spectroscopy
  • Vol. 13,
  • Issue 4,
  • pp. 177-186
  • (2005)

Sugar “Imaging” of Fruit Using a Low Cost Charge-Coupled Device Camera

Not Accessible

Your library or personal account may give you access

Abstract

Sugar “imaging” of fruit has previously been reported using NIR filters and relatively expensive (high signal-to-noise) charge-coupled device (CCD) instrumentation. In a bid to use lower cost CCD instrumentation (criterion of less than AU $5,000 total component costs), the signal-to-noise constraint on calibration model performance was investigated by artificially degrading spectra from a 15-bit AtoD system. A low cost 8-bit CCD camera was then used in conjunction with a filter wheel in a transmittance configuration employing three 50 W halogen lamps. Multiple linear regregression calibrations were developed based on absorbance data of five wavelengths (830, 850, 870, 905 and 930 nm) relevant to sugar and water. Calibration models for the sucrose concentration of solutions on a cellulose matrix were poor (R2 = 0.4) when based on individual pixel data, but acceptable (R2 = 0.98, RMSECV = 1.1) (n = 20, mean = 13.9% total soluble sugars (TSS), SD = 6.04) when based on an average of a 23 × 23 pixel block (i.e. 529 pixels). For a calibration based on melon tissue TSS, using spectral data averaged over groups of 529 pixels, results were poorer than expected (R2 = 0.4, RMSEP = 1.74 (n = 163, mean = 9.45, SD = 2.07% TSS). Predicted TSS output for all pixel blocks from an image was used to generate a false colour image. We conclude that this application requires a higher level of signal-to-noise (for example, 10-bit, > 60 dB CCD).

© 2005 NIR Publications

PDF Article
More Like This
Image recovery from data acquired with a charge-coupled-device camera

Donald L. Snyder, Abed M. Hammoud, and Richard L. White
J. Opt. Soc. Am. A 10(5) 1014-1023 (1993)

Progress in low-light-level charge-coupled device imaging in astronomy

J. A. Tyson
J. Opt. Soc. Am. A 7(7) 1231-1236 (1990)

Low-light-level charge-coupled device imaging in astronomy

J. Anthony Tyson
J. Opt. Soc. Am. A 3(12) 2131-2138 (1986)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.