Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of Near Infrared Spectroscopy
  • Vol. 30,
  • Issue 5,
  • pp. 270-278
  • (2022)

Non-destructive evaluation of strength and stiffness of Eucalyptus pellita. A comparison of near infrared spectroscopy and acoustic wave velocity assessment

Not Accessible

Your library or personal account may give you access

Abstract

Tree improvement programmes benefit from measured data for multiple phenotypes in order to potentially gain maximum genetic leverage for selection. Diameter at breast height, tree height and tree form have traditionally dominated the measured phenotype due to their ease of measurement, and the fact that logs are traded by volume. More complex traits, including those that potentially offer economic benefit in terms of quality and end-product performance such as strength and stiffness, are more difficult to measure in standing trees and are frequently overlooked. These traits are therefore in need of rapid methods of assessment. Tree improvement of Eucalyptus pellita in Malaysian Borneo for solid wood and veneer product utilisation is one such example of where selection for improved stiffness is desirable. Genetic trials of E. pellita were assessed using acoustic velocity measurements at several intervention points, including the standing tree, fallen stem, logs and boards, along with near infrared spectroscopic measurement of the final test samples. Calibrations were developed for modulus of elasticity (MOE), modulus of rupture (MOR) and compression parallel to the grain, using reference values obtained from 3-point bending of small clearwood test samples obtained from the trees following felling and sawing to ensure back-to-log recovery of the test sample location. Dynamic MOE calculated from the standing tree acoustic velocity showed good correlation with the mean MOE from static bending for the wood in the butt log, representing the location where standing tree acoustic velocity measurements were obtained. The Savitzky-Golay second derivative pre-treatment yields the best performing calibration for the microNIR and MPA on ground wood for MOE (R2Cal = 0.76, r2CV = 0.80, r2Pred = 0.46, RMSEC and RMSECV = 1.4 GPa, RMSEP = 2.3 GPa, LV = 3) for the microNIR and R2Cal = 0.98, r2CV and r2Pred = 0.70, RMSEC = 0.5 GPa, RMSECV and RMSEP =1.5 GPa, LV = 4 for the MPA.

© 2022 The Author(s)

PDF Article
More Like This
Stiffness measurement using terahertz and acoustic waves for biological samples

Jong-Hyun Yoon, Young-Joong Yang, Jinho Park, Heyjin Son, Hochong Park, Gun-Sik Park, and Chang-Beom Ahn
Opt. Express 23(25) 32671-32678 (2015)

Laser ultrasonic surface wave dispersion technique for non-destructive evaluation of human dental enamel

Hsiao-Chuan Wang, Simon Fleming, Yung-Chun Lee, Sue Law, Michael Swain, and Jing Xue
Opt. Express 17(18) 15592-15607 (2009)

High-sensitivity non-cooled near-infrared detector based on lithium niobate surface acoustic wave resonators combined with MXene Ti3C2Tx quantum dot thin films

Lihui Feng, Guodong Liu, Peng Guo, Ying Jiang, Xiaoxiao Ma, Yu Chen, and Jiajun Luo
Opt. Express 31(16) 25829-25839 (2023)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.