Transferring near infrared spectral calibration models without standards via multistep wavelength selection

Not Accessible

Your library or personal account may give you access

Abstract

Two case studies were conducted to verify calibration model transfer methods without standards by multi-step wavelength selection, using 3–7 near infrared spectrometers to predict ingredients in corn and total plant alkaloids (TPA) in tobacco leaves. Based on the characteristic wavelengths of Uc, which are selected using the scale-invariant feature transform (SIFT), this study advances two multistep wavelength selection methods by selecting wavelengths with high independence and a high standard deviation of the sample spectra (SDSS). The first method, SIFT-SDSS-CORX, selects important characteristic wavelengths Uc-i from Uc whose SDSS is greater than a threshold SDSSacrit. Subsequently, rx, the correlation coefficient matrix between spectral signals of Uc-i, is calculated, and only one wavelength is retained from those whose correlation coefficients exceed a threshold, rxacrit. The wavelength set Uc-i-rx, which is finally screened, is important and independent. In the second method, SIFT-CORX-SDSS, Uc-rx is first selected from Uc by retaining only one wavelength from those whose correlation coefficients between spectral signals of Uc exceed a threshold, rxbcrit. Subsequently, the wavelengths Uc-rx-i with SDSS exceeding a threshold SDSSbcrit are selected from Uc-rx. Near infrared spectroscopy calibration models for predicting protein and oil in corn and TPA in tobacco leaves were built using partial least squares regression (PLS) based on different wavelength sets of Uc, Uc-i, Uc-i-rx, Uc-rx, and Uc-rx-i, respectively. The latent variables used in the PLS models were determined by an accumulative contribution ratio over 99.9%. The results indicate that the PLS models built on Uc-i-rx and Uc-rx-i are effective on both primary and secondary units for corn and tobacco samples. This study utilises a three-step wavelength selection method to select highly independent, important, and characteristic spectral variables, thereby enhancing the robustness, simplicity, and interpretability of NIR) calibration models and facilitating their transfer to secondary units without standards.

© 2023 The Author(s)

PDF Article
More Like This
Accurate wavelength calibration in the near-infrared for multielement analysis without the need for reference spectra

George Asimellis, Aggelos Giannoudakos, and Michael Kompitsas
Appl. Opt. 45(35) 8855-8862 (2006)

Rapid determination of the main components of corn based on near-infrared spectroscopy and a BiPLS-PCA-ELM model

Lili Xu, Jinming Liu, Chunqi Wang, Zhijiang Li, and Dongjie Zhang
Appl. Opt. 62(11) 2756-2765 (2023)

Measurement of Interferometric Secondary Wavelength Standards in the Near Infrared*

D. H. Rank, J. M. Bennett, and H. E. Bennett
J. Opt. Soc. Am. 46(7) 477-484 (1956)

Supplementary Material (1)

NameDescription
Supplement 1       Supplemental Material - Transferring near infrared spectral calibration models without standards via multistep wavelength selection

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.