Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group

Fiber-based angular filtering for high-resolution Brillouin spectroscopy in the 20-300 GHz frequency range

Open Access Open Access

Abstract

Brillouin spectroscopy emerges as a promising non-invasive tool for nanoscale imaging and sensing. One-dimensional semiconductor superlattice structures are eminently used for selectively enhancing the generation or detection of phonons at few GHz. While commercially available Brillouin spectrometers provide high-resolution spectra, they consist of complex experimental techniques and are not suitable for semiconductor cavities operating at a wide range of optical wavelengths. We develop a pragmatic experimental approach for conventional Brillouin spectroscopy that can integrate a widely tunable excitation-source. Our setup combines a fibered-based angular filtering and a spectral filtering based on a rotating single etalon and a double grating spectrometer for sequential reconstruction of Brillouin spectra. This configuration allows probing confined acoustic phonon modes in the 20-300 GHz frequency range with excellent laser rejection and high spectral resolution. Remarkably, our scheme based on the excitation and collection of the enhanced Brillouin scattering signals through the optical cavity allows for better angular filtering with decreasing phonon frequency. It can be implemented for the study of cavity optomechanics and stimulated Brillouin scattering over broadband optical and acoustic frequency ranges.

© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

1. Introduction

Recently, the acoustic phonons are harnessed, in coherent or incoherent form, for different applications including managing heat transport at the nanoscale, probing elastic properties of thin films and nanostructures, non-invasive imaging of biological membranes and cells, and non-contact inspection of solid-state interfaces in atomically thin heterostructures [1,2]. The urge to study and control the propagation of acoustic phonons has resulted in the emergence of a variety of artificial nanophononic structures presenting confinement of acoustic phonons in the gigahertz to terahertz (GHz-THz) regime [1,38]. One-dimensional semiconductor superlattice structures are eminently used for selectively enhancing the generation or detection of phonons at few GHz. The acoustic cavities designed using semiconductor superlattices exhibit discrete acoustic modes for the confinement of phonons. Moreover, the semiconductor optical cavities confining photons can be exploited to simultaneously confine GHz phonons [911]. The strong overlap of the optical and acoustical fields in a hybrid optophononic cavity leads to the enhancement of the Brillouin scattering signals [12]. The hybrid optophononic cavities in this acoustic frequency range offer a promising platform for optomechanics [13,14]. The presence of confined acoustic modes can be investigated in the frequency domain using Brillouin spectroscopy [8] and in the time domain using pump-probe techniques [15,16], Brownian motion schemes [17], or noise spectroscopy [18].

Conventional Raman spectroscopy techniques are used to study optical phonons in the THz range, which are spectrally far from the laser line. While these techniques are usually compatible with excitation sources over a wide range in optical wavelengths, they provide an insufficient stray-light rejection in order to observe Brillouin modes as low as a few tens of GHz =∼ 1 cm-1. Thus, Brillouin spectroscopy techniques are frequently employed to probe the tailored broadband acoustic spectrum of nanostructures. In the past few decades, Brillouin spectroscopy has taken a giant leap forward in terms of measuring the Brillouin frequency shifts ranging from 0.1 GHz - 1THz with ultra-high resolution of 0.003 cm-1 = 0.1 GHz [1924]. The widely used advanced Brillouin spectrometers providing superior performance are based on the virtually imaged phase array (VIPA) equipped with notch filters and on the scanning multiple pass tandem Fabry-Perot interferometers (TFPI) [24]. These spectrometers are very useful in characterizing the viscoelastic properties of matter with high accuracy and spectral resolution. However, the performance of these techniques strongly relies on an optimization of the optics and detectors to work at a fixed wavelength. Optical scans as a function of wavelength imply intricate optical alignments. Optophononic cavities present optical modes in a wide range of wavelengths. This limits the use of commercial Brillouin spectrometers in probing the confined acoustic modes in hybrid optophononic cavities.

In this paper, we discuss a custom-built accessible and versatile Brillouin spectroscopy scheme to measure longitudinal acoustic phonons in the 20-300 GHz frequency range without optical wavelength restriction, thereby overcoming the limitations of existing Raman and Brillouin spectrometers.

2. Methods

The experiments are performed on semiconductor optophononic planar cavities with a typical quality factor of 2000 where the Brillouin scattering signal is enhanced by the mode of the optical cavity [12,25,26]. In order to observe the confined acoustic modes in the Brillouin spectrum with sufficiently high spectral resolution and contrast, we propose a combination of angular and spectral filtering techniques. We implement the angular filtering with a single-mode fiber to efficiently filter out stray-light from the laser and increase the signal to background ratio. We realize the additional spectral filtering with a tandem of an etalon and a double Raman spectrometer. This combination has enabled us to observe the low frequency acoustic modes of a cavity at 20 GHz with a simple etalon, whose Brillouin signatures are otherwise concealed by the excitation laser background.

We have studied two samples (I and II) confining acoustic phonons in cavity resonances at 300 GHz and 18.3 GHz respectively by exploiting topological properties of semiconductor multilayers [27]. Each sample also constitutes an optical microcavity with a cavity mode around 900 nm. This optical cavity is designed to enhance the photoelastic response of the structure [25]. For the 300 GHz sample, we embedded the acoustic cavity into the optical cavity as detailed later on. For the 18.3 GHz sample, the phononic resonator simultaneously confines photons of the same wavelength [9,11,28].

Both samples are grown by molecular beam epitaxy on a (001) GaAs substrate. Sample I is made of two optical distributed Bragg reflectors (DBRs) enclosing an optical spacer with an optical path-length of 2.5λ [29] at a resonance optical wavelength around 910 nm. The optical spacer is composed of two concatenated acoustic DBRs with different topological properties designed to confine phonons at 300 GHz. The top (bottom) optical DBR is made of 14(18) periods of 65.1 nm/76.3 nm Al0.95Ga0.05As/Al0.1Ga0.9As. The acoustic top (bottom) DBR is formed by 16 periods (each) of 8.7 nm/8.4 nm (7.5 nm/10.0 nm) GaAs/AlAs layers. Sample II consists of two DBRs concatenated to confine simultaneously an acoustic interface mode at 18.3 GHz and an optical interface mode at 920 nm [27,30]. The DBRs are formed by 14 (16) periods of 65.1 nm / 231.1 nm (195.5 nm / 77.0 nm) GaAs/Al0.95Ga0.05As layers for the top (bottom). The samples were grown with a spatial gradient such that they present position dependent resonance wavelengths.

3. Results

The principal goal in Brillouin spectroscopy is the extraction of the low intensity Brillouin peaks with maximum suppression of the stray-light in the collected signal. Figure 1 shows the schematic representation of our home-built Brillouin spectroscopy setup. A collimated laser beam from a tunable continuous wave (cw) Ti:Sapphire laser (M2 SolsTis) operating at the wavelength in resonance with the fundamental optical cavity mode of the studied sample is used as an excitation source. The excitation laser with <5 MHz linewidth is focused on the sample with a spot diameter of 10 µm using a plano-convex lens OL (focal length, f = 13 mm). The same lens is used to collect the scattered signal from the sample. The excitation laser beam passes through a mirror M mounted on a translation stage that allows us to vary the incident angle with respect to the surface normal. We collect the signal into a single mode fiber, pass it through an etalon filter and finally analyze it with a double spectrometer. In the following, we discuss this implementation in detail.

 figure: Fig. 1.

Fig. 1. Schematic of the Brillouin spectroscopy setup. A tunable cw Ti:Sapphire laser excites the sample with an angle of incidence of 13°. The dispersion curves illustrate the DOR condition for different acoustic phonon frequencies providing an angular offset θ (see text for details). The Brillouin signal is collected into a single mode fiber, which allows us to filter out the laser spatially and sent through a tunable etalon into a double grating spectrometer. FC1, FC2, E, S1, S2 and BS stand for fiber coupler 1 and 2, etalon, spectrometer slits 1 and 2, and beam splitter, respectively.

Download Full Size | PDF

We designed the setup in an approximated backscattering geometry with near normal excitation. The measurements are performed in the double optical resonance (DOR) condition to enhance the Brillouin scattering [12,25,31]. We achieved the DOR condition by exploiting the in-plane photon dispersion of the optical cavity mode as shown in Fig. 1. Under this condition, the excitation laser and the Brillouin scattered signal are coupled to the optical cavity mode. The wavenumber k of the optical mode in the cavity can be decomposed as k = kz + k// where k// is the in-plane component and kz is the normal component. The resonance is achieved for a given kz. The in-plane component k// increases with the angle of incidence. Therefore, keeping kz constant and varying k// implies a blue-shift of the optical cavity resonance when tuning the angle of incidence away from the surface normal. We optimized the collection of the Brillouin signal resulting from the Stokes process. In this process, the energy of the incoming beam is higher than the energy of the scattered Brillouin signal which means that k// of the incoming beam is larger than that of the scattered signal. The energy of the scattered signal depends on the frequency of the phonons involved in the process. For an incident in-plane wave vector kept constant, we can observe two configurations. For phonons in the 300 GHz range, the energy shift is large enough that the outgoing signal is normal to the surface. Whereas for phonons in the 20 GHz range, the energy shift is significantly smaller so the outgoing signal has k// ≠ 0 and is scattered with an angle. We benefit from the DOR to spatially filter the Brillouin signal by selecting the scattered signal for a given k// with a fiber coupler [25,26].

Excitation laser as well as scattering signal can be collected through the cavity mode by tuning the angle of incidence and the collection angle (θ), respectively [25]. The angle θ defines the angular offset with respect to that of the excitation laser in order to achieve the Brillouin scattered signal at the required phonon frequency. The spatial gradient of the sample under study enables us to maximize the coupling of the scattering signal with the optical cavity by changing the excitation laser spot position. The combination of incident angle and sample position is set to obtain the maximal spectral coupling of the excitation and scattered Brillouin signal with the optical cavity mode. In our case for a certain position on the sample, the angle of incidence is fixed at 13° away from the normal for a 3 mm displacement of mirror M.

The Brillouin signal is then collected at input port FC1 consisting of an 11.17 mm focal length fiber coupler connected to a single mode fiber (Thorlabs 780HP, core diameter 4.5 µm) with an NA of 0.13. The single mode fiber allows us to spatially filter the Brillouin signal and reject the reflected excitation laser. The filtering with the fiber is essential to attenuate diffuse laser light that is elastically scattered on the sample and on the multiple optical elements. For phonons at ∼20 GHz, we take advantage of the small angular offset θ=2° to maximize the distance between the reflected laser beam and the Brillouin signal at the input port FC1. This is done by collecting the scattered signal on the same side of the normal as the incoming laser beam (see experimental setup in Fig. 1). In this second configuration, the angular filtering thus selects a circular section of NA=0.13*11.17/13 = 0.11 from the annular Brillouin radiation pattern. For the experimental quality factors and angle of incidence, we estimate a maximum Brillouin collection efficiency of 14% inside the fiber. Note that this efficiency is substantially larger for Brillouin emission at normal incidence due to the circular radiation pattern and its larger overlap with the fiber NA. In both configurations, we align the fiber port FC1 by mimicking the spatial mode of the Brillouin signal with the reflected excitation laser. That is, when detecting Brillouin modes around 300 GHz, we placed the movable mirror M such that the laser impinges on the sample under normal incidence and coupled the reflected laser into the collection fiber. Then, we translate mirror M such that the laser is again incident at 13° for the spectroscopy measurement. Similarly, we align FC1 for phonons at ∼20 GHz by injecting the laser under an angle of incidence of -11°. A careful pre-alignment of the objective lens OL guarantees that the laser focus maintains its position on the sample while translating mirror M.

The fiber-coupled signal is then passed through the etalon E and sent to the entrance slit S1 of a double grating spectrometer. Our setup consists of a tandem between a double spectrometer and a simple etalon E that permits us to reconstruct a Brillouin spectrum with high spectral resolution compared to the use of a single spectrometer. As the name suggests the double grating spectrometer is a combination of two monochromator chambers connected through an intermediate slit S2. The slit S2 allows us to select the measured optical wavelength range and is particularly used to reduce the level of the stray light generated inside the first chamber from the remaining excitation laser. The signal is then detected by a liquid nitrogen cooled charge-coupled device (CCD) at the exit of the spectrometer. The spectrometer provides an experimental resolution of 9 GHz which is measured as full width at half maximum (FWHM) of the laser source, prior to the use of the etalon. The etalon has a linewidth of 2 GHz and a free spectral range (FSR) of 60 GHz at a peak transmission of 83%. The etalon is mounted on a motorized rotation stage on a magnetic base and can be easily inserted or removed. We rotate the etalon to vary the angle of incidence and thereby tuning the transmission modes of the etalon. The Brillouin spectrum is a reconstruction from a series of measurements where a mode of the etalon is tuned over a full FSR. The broadband white light source is used to get the position of the transmission lines of the etalon (see Fig. 1). Figure 2(a) shows the design structure of sample I. The acoustic cavity composed of two concatenated distributed Bragg reflectors (DBRs) is enclosed by two optical DBRs forming an optical cavity. The measured optical reflectivity spectrum in the inset of Fig. 2(b) shows a dip associated with the optical cavity mode for sample I. The optical cavity mode is centered around 910 nm for an excitation angle of 13°, with FWHM of ∼0.4 nm. We have resonantly excited the sample I with an excitation laser tuned at 909.45 nm with an incident power of 16 mW measured before the lens OL.

 figure: Fig. 2.

Fig. 2. (a) Schematic of the optophononic cavity structure of sample I. (b) The calculated (red solid) and experimental (blue line and symbols) Brillouin spectrum with etalon measured for sample I. The Brillouin spectrum measured without etalon (grey dashed line with an offset of 0.5) is shown with an offset of 0.5 for comparison. Residual laser background contributions are fitted with an exponential decay over the frequency range of 0 to 100 GHz (light solid grey and blue line, respectively). The peak at 60 GHz marked with a black dot is parasitic light from the laser. The inset displays the optical cavity mode as a dip in the reflectivity spectrum measured for sample I at an incident angle of 13°.

Download Full Size | PDF

Figure 2(b) presents the experimental Brillouin signal prior to (grey dashed line) and after (blue dotted line) the insertion of etalon for sample I. The peak at 300 GHz corresponds to the first interface mode between the two acoustic DBRs. The two peaks at ∼260 GHz and 335 GHz correspond to modes propagating in the acoustic DBRs [29]. The peaks at lower frequencies < 250 GHz correspond to acoustic modes propagating in the full optical structure. They are multiple harmonics of the mode at 37 GHz. The peak at 37 GHZ is related to the Brillouin mode arising due to the scattering from the GaAs substrate and is also due to modes propagating into the structure. We have compared our experimental results with a calculated Brillouin cross-section using a photoelastic model and transfer matrix method for the structure embedded in GaAs [29]. The calculated spectrum (red solid line) in Fig. 2(b) is convoluted with the linewidth of the etalon (2 GHz) to match the resolution of the experimental spectrum. The measured acoustic modes with small oscillations in the experimental spectrum are consistent with the calculations. The peak at 37 GHz also agrees well with our calculations.

The etalon serves two main purposes in our experiment: First, it increases the spectral resolution beyond the resolution of the double spectrometer. Second, it improves the rejection of scattered laser light in addition to the suppression of the fiber filter. In Fig. 2(b), we observe both these effects. For the Brillouin modes around 300 GHz, the main contribution of the etalon is an increase in resolution. This becomes particularly evident in the better-resolved shoulders around 290 GHz and 255 GHz. For the Brillouin peaks at 40 GHz and its multiples, the main contribution of the etalon is the better background rejection. To quantify this improvement, we fitted the background in the range from 0 to 100 GHz to an exponential decay (solid light grey and light blue line in Fig. 2(b)) and calculated the signal to background ratio (SBR) for the peak at 40 GHz with and without etalon. This calculation results in an SBR=24 without and SBR=162 with etalon, i.e., an almost sevenfold improvement.

Figure 3(a) (dashed line) displays the transmission function of the etalon measured by sending collimated white light through the etalon as shown in Fig. 1. By rotating the etalon, the transmission lines move and span all the frequencies. The angle of rotation is scanned from normal incidence to 1.8° to cover the FSR with a step of 0.02°. The principle of reconstruction of the Brillouin spectrum from the etalon measurements consists of the following steps:

 figure: Fig. 3.

Fig. 3. Data analysis using an etalon (a) (dashed grey) Transmission line spectrum measured using broadband white light at normal incidence. (black) Brillouin signal acquired through the etalon at normal incidence. (red) Lorentzian fit of the Brillouin spectrum. (b) Displacement of the etalon lines as a function of the angle of incidence of the light on the etalon (blue points) measured positions, (red lines) fitted position. (c) Brillouin signal acquired through the etalon as a function of the angle of incidence.

Download Full Size | PDF

First, the displacement of transmission lines as a function of the angle of rotation is extracted from the transmission measurement done with the white light; see Fig. 3(b). The displacement of each transmission peak with change in rotation angle represents a parabola. It provides one parabola for each mode of the etalon measured in the spectrometer window in Fig. 3(a). In this situation, the displacement of the transmission line is limited by the frequency resolution of the spectrometer and pixel size of the detector. Therefore, the transmission lines progress in a stepwise fashion. The displacement of each transmission line is fitted with a parabola to smooth the steps and increase the resolution.

Second, the Brillouin scattering signal is acquired in a similar way. Thus, for each Brillouin spectrum acquired through the etalon there is an associated white light spectrum with the position of the transmission lines. Figure 3(a) displays a Brillouin spectrum (black solid line) for the etalon placed at normal incidence on top of the corresponding transmission line (dashed grey line). The Brillouin spectrum is acquired as a function of the angle of rotation of the etalon. The Brillouin peaks appear in the measured spectrum as soon as they coincide with the transmission line of the etalon at that particular rotation angle; see Fig. 3(c). It is important to note that even after blocking the laser using slit S2, the background intensity of the measured spectrum increases when the transmission line coincides with the laser. The peak with the star on top in the measured spectrum shown in Fig. 2(b) is a parasitic line from the laser which arises when the laser is overlapped with the mode of the etalon. That corresponds to a rotation angle of ∼0.78°. The acquisition time over a full FSR depends on the acquisition time for one spectrum and is limited by the duration of rotation of the mount. The spectrum is acquired for 4 seconds at each data point. Therefore, if the Brillouin signal is strong enough, the scan can be performed in 10 minutes for a given step-size of 0.02°.

Third, the Brillouin scattering spectra acquired through the etalon are fitted with Lorentzian peaks centered at each transmission line of the etalon (see Fig. 3(a) red lines). It allows us to reduce the light due to the laser reflection on the sample.

Fourth, the Lorentzian fits are integrated on areas with a window of 17 GHz centered on the transmission lines. Each integral is then associated to a position of the transmission line at a given angle. By doing it systematically for each angle, a piece of the Brillouin spectrum is attributed to one transmission line. Therefore, the Brillouin spectrum can be reconstructed by concatenating the pieces. One can note that the strongest Brillouin peaks are not fully rejected in between two transmission lines of the etalon. The method used here could be further optimized by always integrating the signal convoluted with the white light spectrum around the fixed position of the Brillouin peaks.

In order to test the technique at lower frequencies, we studied Sample II, which presents a confined acoustic mode at 18.3 GHz. The inset of Fig. 4(a) displays the schematic of the structure where two DBRs are concatenated to simultaneously confine the optical and acoustical fields at the interface. Sample II is also excited resonantly at an excitation laser wavelength of 924.72 nm, with an excitation power of 6.3 mW. The excitation laser is kept with the same angle of incidence of 13°. In this case to satisfy the DOR condition, the scattered signal is no longer collected at normal incidence but with an angle θ = 2° as shown in Fig. 1, designated for the Brillouin shift of 18.3 GHz which amounts to a difference in optical wavelength of 0.06 nm. Remarkably, the distance between the reflected laser and the signal at the input of the fiber is larger than in the previous case (see Fig. 1), enabling a better fiber-based angular filtering. Here, the mode of the etalon scanned the full FSR using a step of 0.01°.

 figure: Fig. 4.

Fig. 4. (a) The experimental Brillouin spectra without (grey dashed line with an offset of 0.5) and with etalon (blue line and symbols) along with the calculated spectrum (red solid) for sample II. Residual laser background contributions are fitted with an exponential decay over the frequency range of 0 to 100 GHz (light solid grey and blue line, respectively). The peak at 63 GHz marked with a black dot is parasitic light from the laser. Schematic of the DBR structure of sample II is displayed as an inset. (b) The acoustic displacement for the 1st, 3rd and 5th harmonic is represented at the interface.

Download Full Size | PDF

Figure 4(a) displays the Brillouin spectra measured with and without the etalon together with the calculated spectrum for sample II. The peak at 18.3 GHz is the first interface mode, which we observe in DOR condition. The peaks at 56 and 90 GHz also correspond to interface modes between the two DBRs at higher frequencies and are the third and fifth harmonics of the fundamental resonance. The acoustic displacement at the interface is displayed in Fig. 4(b) for the three harmonics observed in our measurement. As before, the peak at 37 GHz is related to the Brillouin mode arising due to the scattering from the GaAs substrate that agrees well with our calculations. The processed spectrum is obtained following the same reconstruction method as sample I. The calculated spectrum obtained for the structure is in complete agreement with the experimental result. The intense peak which appears close to the laser line on the Brillouin spectrum without etalon (grey dashed line) of Fig. 4(a) is due to laser light diffracted by the edge of the slit S2. Despite this scattered laser line, the peak corresponding to the interface mode at 18.3 GHz is already visible thanks to the efficiency of the angular filtering. However, its superposition with the remaining unwanted laser background leads to an artificial red shift of the peak. When adding the etalon to perform a better spectral filtering, this background is efficiently suppressed and the signal contrast is significantly improved for the mode at 18.3 GHz. To quantify this improvement, we fitted the background in the range from 0 to 100 GHz to an exponential decay (solid light grey and light blue line in Fig. 4(a)) following the same procedure as for Fig. 2(b). We calculated the SBR for the peak at 18.3 GHz resulting in SBR=0.65 without and SBR=2.53 with etalon, i.e., in a fourfold improvement.

A similar experimental technique has been discussed in Ref. [32], which presents a tandem of a gas-pressure controlled Fabry-Perot interferometer and a triple spectrometer to access broadband acoustic frequencies in DBR based microcavities. The technique presents Raman/Brillouin spectra with high resolution of ∼0.01cm-1 = 0.3 GHz. In contrast to our scheme, the study reports, the tuning of angle of incidence to remain in the DOR condition while collecting the scattered signal at normal incidence. There, a small aperture is used to filter out the Brillouin signal from the reflected laser which results in insufficient stray-light rejection for modes at lower acoustic frequencies with strong parasitic laser lines in the spectrum. In our scheme, we gain better laser rejection at 20 GHz by exciting and collecting the scattered signal away from the normal leading to spatial separation of the reflected laser and of the signal which is filtered by a single mode fiber.

4. Conclusion

In conclusion, we have applied a combination of optical filtering techniques that allow us to access the spontaneous Brillouin scattering signal originated by the confined acoustic mode of a semiconductor microcavity. The technique relies on the angular filtering with a single mode fiber permitted by the angular offset between the incoming laser and scattered signal. It helps to selectively collect the Brillouin signal and to attenuate stray light from the laser. In addition, this technique works over a large range of optical excitation wavelengths using the same set of broadband optics. The rotating etalon, which we use for the sequential point-by-point reconstruction of Brillouin spectra, has two functions here: On one hand, it is used to filter the signal to increase the spectral resolution. On the other, it blocks the remains of the laser before the spectrometer to gain high-contrast. Despite the simplicity of the proposed experimental setup, the resolutions (∼2 GHz) and stray-light rejection are remarkable in comparison to a Raman spectrometer. With an excitation power of 25 mW, we manage to get well-defined peaks within 1 second per datapoint. The resulting improvement in frequency-dependent SBR amounts to a sevenfold improvement at 40 GHz and a fourfold improvement at 18.3 GHz. The signal/noise ratio and integration time could be further improved by using annular apertures in a different collection approach. Our signals profit from the enhancement of both acoustic and optical fields and provide a prospective tool for the study of stimulated Brillouin scattering at 20 GHz with high-resolution. The simplified detection of high frequency acoustic phonons has implications in the study of phonon-assisted emission from a gain medium such as quantum well or dot embedded in an optophononic cavity. Such high-resolution spectroscopy could also be valuable to probe any change in the density of acoustic modes by probing the phonon sideband of quantum emitters coupled to an acoustic cavity. The proposed experimental scheme thus offers an accessible and versatile platform for exploring cavity optomechanics and phonon lasing at broadband acoustic frequencies.

Funding

European Research Council (715939); H2020 Future and Emerging Technologies (824140); French RENATECH Network; Agence Nationale de la Recherche (ANR-10-LABX-0035); Deutsche Forschungsgemeinschaft (401390650).

Acknowledgments

The authors acknowledge funding from European Research Council Starting Grant No. 715939, Nanophennec. This work was supported by the European Commission in the form of the H2020 FET Proactive project TOCHA (No. 824140). The authors acknowledge funding from the French RENATECH network and through a public grant overseen by the ANR as part of the “Investissements d'Avenir” program (Labex NanoSaclay Grant No. ANR-10-LABX-0035). M.E. acknowledges funding from the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) Project 401390650.

Disclosures

The authors declare no conflicts of interest.

References

1. S. Volz, J. Ordonez-Miranda, A. Shchepetov, M. Prunnila, J. Ahopelto, T. Pezeril, G. Vaudel, V. Gusev, P. Ruello, E. M. Weig, M. Schubert, M. Hettich, M. Grossman, T. Dekorsy, F. Alzina, B. Graczykowski, E. Chavez-Angel, J. Sebastian Reparaz, M. R. Wagner, C. M. Sotomayor-Torres, S. Xiong, S. Neogi, and D. Donadio, “Nanophononics: state of the art and perspectives,” Eur. Phys. J. B 89(1), 15 (2016). [CrossRef]  

2. J. L. Arlett, E. B. Myers, and M. L. Roukes, “Comparative advantages of mechanical biosensors,” Nat. Nanotechnol. 6(4), 203–215 (2011). [CrossRef]  

3. B. J. Eggleton, C. G. Poulton, P. T. Rakich, M. J. Steel, and G. Bahl, “Brillouin integrated photonics,” Nat. Photonics 13(10), 664–677 (2019). [CrossRef]  

4. C. Y. T. Huang, F. Kargar, T. Debnath, B. Debnath, M. D. Valentin, R. Synowicki, S. Schoeche, R. K. Lake, and A. A. Balandin, “Phononic and photonic properties of shape-engineered silicon nanoscale pillar arrays,” Nanotechnology 31(30), 30LT01 (2020). [CrossRef]  

5. M. Eichenfield, J. Chan, R. M. Camacho, K. J. Vahala, and O. Painter, “Optomechanical crystals,” Nature 462(7269), 78–82 (2009). [CrossRef]  

6. P. V. Santos, M. Msall, and S. Ludwig, “Acoustic Field for the Control of Electronic Excitations in Semiconductor Nanostructures,” in 2018 IEEE International Ultrasonics Symposium (IUS) (IEEE, 2018), pp. 1–4.

7. F. G. S. Santos, Y. A. V. Espinel, G. O. Luiz, R. S. Benevides, G. S. Wiederhecker, and T. P. M. Alegre, “Hybrid confinement of optical and mechanical modes in a bullseye optomechanical resonator,” Opt. Express 25(2), 508–529 (2017). [CrossRef]  

8. J.-C. Beugnot, S. Lebrun, G. Pauliat, H. Maillotte, V. Laude, and T. Sylvestre, “Brillouin light scattering from surface acoustic waves in a subwavelength-diameter optical fibre,” Nat. Commun. 5(1), 5242 (2014). [CrossRef]  

9. A. Fainstein, N. D. Lanzillotti-Kimura, B. Jusserand, and B. Perrin, “Strong Optical-Mechanical Coupling in a Vertical GaAs/AlAs Microcavity for Subterahertz Phonons and Near-Infrared Light,” Phys. Rev. Lett. 110(3), 037403 (2013). [CrossRef]  

10. N. D. Lanzillotti-Kimura, A. Fainstein, and B. Jusserand, “Towards GHz–THz cavity optomechanics in DBR-based semiconductor resonators,” Ultrasonics 56, 80–89 (2015). [CrossRef]  

11. G. Arregui, N. D. Lanzillotti-Kimura, C. M. Sotomayor-Torres, and P. D. García, “Anderson Photon-Phonon Colocalization in Certain Random Superlattices,” Phys. Rev. Lett. 122(4), 043903 (2019). [CrossRef]  

12. N. D. Lanzillotti-Kimura, A. Fainstein, B. Jusserand, and A. Lemaître, “Resonant Raman scattering of nanocavity-confined acoustic phonons,” Phys. Rev. B 79(3), 035404 (2009). [CrossRef]  

13. M. Aspelmeyer, T. J. Kippenberg, and F. Marquardt, “Cavity optomechanics,” Rev. Mod. Phys. 86(4), 1391–1452 (2014). [CrossRef]  

14. D. Wigger, S. Lüker, D. E. Reiter, V. M. Axt, P. Machnikowski, and T. Kuhn, “Energy transport and coherence properties of acoustic phonons generated by optical excitation of a quantum dot,” J. Phys.: Condens. Matter 26(35), 355802 (2014). [CrossRef]  

15. C. Lagoin, B. Perrin, P. Atkinson, and D. Garcia-Sanchez, “High spectral resolution of GaAs/AlAs phononic cavities by subharmonic resonant pump-probe excitation,” Phys. Rev. B 99(6), 060101 (2019). [CrossRef]  

16. G. Arregui, O. Ortíz, M. Esmann, C. M. Sotomayor-Torres, C. Gomez-Carbonell, O. Mauguin, B. Perrin, A. Lemaître, P. D. García, and N. D. Lanzillotti-Kimura, “Coherent generation and detection of acoustic phonons in topological nanocavities,” APL Photonics 4(3), 030805 (2019). [CrossRef]  

17. T. J. Kippenberg and K. J. Vahala, “Cavity Optomechanics: Back-Action at the Mesoscale,” Science 321(5893), 1172–1176 (2008). [CrossRef]  

18. M. Sansa, M. Defoort, A. Brenac, M. Hermouet, L. Banniard, A. Fafin, M. Gely, C. Masselon, I. Favero, G. Jourdan, and S. Hentz, “Optomechanical mass spectrometry,” Nat. Commun. 11(1), 3781 (2020). [CrossRef]  

19. F. Scarponi, S. Mattana, S. Corezzi, S. Caponi, L. Comez, P. Sassi, A. Morresi, M. Paolantoni, L. Urbanelli, C. Emiliani, L. Roscini, L. Corte, G. Cardinali, F. Palombo, J. R. Sandercock, and D. Fioretto, “High-Performance Versatile Setup for Simultaneous Brillouin-Raman Microspectroscopy,” Phys. Rev. X 7(3), 031015 (2017). [CrossRef]  

20. G. Rozas, B. Jusserand, and A. Fainstein, “Fabry-Pérot-multichannel spectrometer tandem for ultra-high resolution Raman spectroscopy,” Rev. Sci. Instrum. 85(1), 013103 (2014). [CrossRef]  

21. X.-L. Liu, H.-N. Liu, J.-B. Wu, H.-X. Wu, T. Zhang, W.-Q. Zhao, and P.-H. Tan, “Filter-based ultralow-frequency Raman measurement down to 2 cm −1 for fast Brillouin spectroscopy measurement,” Rev. Sci. Instrum. 88(5), 053110 (2017). [CrossRef]  

22. G. Antonacci, S. De Panfilis, G. Di Domenico, E. DelRe, and G. Ruocco, “Breaking the Contrast Limit in Single-Pass Fabry-Pérot Spectrometers,” Phys. Rev. Appl. 6(5), 054020 (2016). [CrossRef]  

23. Y. Ike, S. Tsukada, and S. Kojima, “High-resolution Brillouin spectroscopy with angular dispersion-type Fabry-Perot interferometer and its application to a quartz crystal,” Rev. Sci. Instrum. 78(7), 076104 (2007). [CrossRef]  

24. Z. Coker, M. Troyanova-Wood, A. J. Traverso, T. Yakupov, Z. N. Utegulov, and V. V. Yakovlev, “Assessing performance of modern Brillouin spectrometers,” Opt. Express 26(3), 2400–2409 (2018). [CrossRef]  

25. A. Fainstein, B. Jusserand, and V. Thierry-Mieg, “Raman Scattering Enhancement by Optical Confinement in a Semiconductor Planar Microcavity,” Phys. Rev. Lett. 75(20), 3764–3767 (1995). [CrossRef]  

26. P. Lacharmoise, A. Fainstein, B. Jusserand, and V. Thierry-Mieg, “Optical cavity enhancement of light–sound interaction in acoustic phonon cavities,” Appl. Phys. Lett. 84(17), 3274–3276 (2004). [CrossRef]  

27. M. Esmann, F. R. Lamberti, P. Senellart, I. Favero, O. Krebs, L. Lanco, C. Gomez Carbonell, A. Lemaître, and N. D. Lanzillotti-Kimura, “Topological nanophononic states by band inversion,” Phys. Rev. B 97(15), 155422 (2018). [CrossRef]  

28. F. R. Lamberti, Q. Yao, L. Lanco, D. T. Nguyen, M. Esmann, A. Fainstein, P. Sesin, S. Anguiano, V. Villafañe, A. Bruchhausen, P. Senellart, I. Favero, and N. D. Lanzillotti-Kimura, “Optomechanical properties of GaAs/AlAs micropillar resonators operating in the 18 GHz range,” Opt. Express 25(20), 24437–24447 (2017). [CrossRef]  

29. M. Esmann, F. R. Lamberti, A. Harouri, L. Lanco, I. Sagnes, I. Favero, G. Aubin, C. Gomez-Carbonell, A. Lemaître, O. Krebs, P. Senellart, and N. D. Lanzillotti-Kimura, “Brillouin scattering in hybrid optophononic Bragg micropillar resonators at 300 GHz,” Optica 6(7), 854–859 (2019). [CrossRef]  

30. M. Xiao, Z. Q. Zhang, and C. T. Chan, “Surface Impedance and Bulk Band Geometric Phases in One-Dimensional Systems,” Phys. Rev. X 4(2), 021017 (2014). [CrossRef]  

31. A. Fainstein and B. Jusserand, “Raman Scattering in Resonant Cavities,” in Light Scattering in Solid IX, Topics in Applied Physics (Springer, Berlin, Heidelberg, 2006), pp. 17–110.

32. S. Anguiano, G. Rozas, A. E. Bruchhausen, A. Fainstein, B. Jusserand, P. Senellart, and A. Lemaître, “Spectra of mechanical cavity modes in distributed Bragg reflector based vertical GaAs resonators,” Phys. Rev. B 90(4), 045314 (2014). [CrossRef]  

Cited By

Optica participates in Crossref's Cited-By Linking service. Citing articles from Optica Publishing Group journals and other participating publishers are listed here.

Alert me when this article is cited.


Figures (4)

Fig. 1.
Fig. 1. Schematic of the Brillouin spectroscopy setup. A tunable cw Ti:Sapphire laser excites the sample with an angle of incidence of 13°. The dispersion curves illustrate the DOR condition for different acoustic phonon frequencies providing an angular offset θ (see text for details). The Brillouin signal is collected into a single mode fiber, which allows us to filter out the laser spatially and sent through a tunable etalon into a double grating spectrometer. FC1, FC2, E, S1, S2 and BS stand for fiber coupler 1 and 2, etalon, spectrometer slits 1 and 2, and beam splitter, respectively.
Fig. 2.
Fig. 2. (a) Schematic of the optophononic cavity structure of sample I. (b) The calculated (red solid) and experimental (blue line and symbols) Brillouin spectrum with etalon measured for sample I. The Brillouin spectrum measured without etalon (grey dashed line with an offset of 0.5) is shown with an offset of 0.5 for comparison. Residual laser background contributions are fitted with an exponential decay over the frequency range of 0 to 100 GHz (light solid grey and blue line, respectively). The peak at 60 GHz marked with a black dot is parasitic light from the laser. The inset displays the optical cavity mode as a dip in the reflectivity spectrum measured for sample I at an incident angle of 13°.
Fig. 3.
Fig. 3. Data analysis using an etalon (a) (dashed grey) Transmission line spectrum measured using broadband white light at normal incidence. (black) Brillouin signal acquired through the etalon at normal incidence. (red) Lorentzian fit of the Brillouin spectrum. (b) Displacement of the etalon lines as a function of the angle of incidence of the light on the etalon (blue points) measured positions, (red lines) fitted position. (c) Brillouin signal acquired through the etalon as a function of the angle of incidence.
Fig. 4.
Fig. 4. (a) The experimental Brillouin spectra without (grey dashed line with an offset of 0.5) and with etalon (blue line and symbols) along with the calculated spectrum (red solid) for sample II. Residual laser background contributions are fitted with an exponential decay over the frequency range of 0 to 100 GHz (light solid grey and blue line, respectively). The peak at 63 GHz marked with a black dot is parasitic light from the laser. Schematic of the DBR structure of sample II is displayed as an inset. (b) The acoustic displacement for the 1st, 3rd and 5th harmonic is represented at the interface.
Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.