Abstract
The injection locking experiments were divided into two regimes. The first was the short pulse regime in which injection pulses varying between 240 ns and 35 ns were used to injection lock optical pulses of ~600 ns duration. These experiments were performed at room temperature on the 353 nm band. The second was the long pulse regime in which ~600 ns optical pulses were injection locked with injection pulses of ~600 ns. These experiments were performed on the 353 nm band at room temperature and on the 351 nm and 353 nm bands at temperatures up to 170°C.
© 1983 Optical Society of America
PDF ArticleMore Like This
C.B. Edwards, F.O' Neill, M.J. Shaw, D. Baker, and D. Craddock
MB4 Excimer Lasers (EL) 1983
S.F. Fulghum, D.W. Trainor, C. Duzy, and H.A. Hyman
TuB2 Excimer Lasers (EL) 1983
Irving J. Bigio and Michael Slatkine