Abstract
An optimum design of static Fourier-transform spectrometer based on Savert prisms is presented in this paper. A new method of increasing path difference and resolution of spectrometer is given. When the angle between the crystal optical axis of the first Savert prism and the incident interface is 58°and the angle between the crystal optical axis of the second Savert prism and the incident interface is 28°, the maximum path difference will be 0.63 mm, the maximum resolution will be 15.8 cm^(-1), and the whole field-of-view will reach 6°.
© 2005 Chinese Optics Letters