Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Chinese Optics Letters
  • Vol. 18,
  • Issue 11,
  • pp. 113401-
  • (2020)

High efficiency X-ray diffraction diagnostic spectrometer with multi-curvature bent crystal

Not Accessible

Your library or personal account may give you access

Abstract

In spectral diagnostic physics experiments of inertial confinement fusion, the spectral signal is weak due to the low diffraction efficiency when using bent crystals. A spectral diagnostic instrument with high efficiency and wide spectral range is urgently needed. A multi-curvature bent crystal with multi-energy focusing ability is proposed based on the traditional conical crystal geometry. It has advantages of wide spectral range, strong focusing ability, and high spectral resolution. It also can eliminate the imaging aberration in principle due to rotational symmetry for the incoming X rays. A spectral diagnostic experiment based on a fabricated multi-curvature α-quartz crystal was accomplished using a titanium X-ray tube of the bent crystal, and the corresponding experimental data using a plane α-quartz crystal was also acquired to demonstrate the strong focusing ability. The result shows that the Kα intensity of the multi-curvature α-quartz crystal is 157 times greater than that of the plane crystal, and the corresponding energy range is about 4.51–5.14 keV. This diagnostic instrument could be combined with a streak camera at a vertical direction so as to intensify the diffracted X-ray signal with a wide spectral range.

© 2020 Chinese Laser Press

PDF Article
More Like This
High efficiency, high quality x-ray optic based on ellipsoidally bent highly oriented pyrolytic graphite crystal for ultrafast x-ray diffraction experiments

I. Uschmann, U. Nothelle, E. Förster, V. Arkadiev, N. Langhoff, A. Antonov, I. Grigorieva, R. Steinkopf, and A. Gebhardt
Appl. Opt. 44(24) 5069-5075 (2005)

Efficiency calibrations of cylindrically bent transmission crystals in the 20 to 80 keV x-ray energy range

Csilla I. Szabo, Uri Feldman, Stephen Seltzer, Lawrence T. Hudson, Michelle O’Brien, Hye-Sook Park, and John F. Seely
Opt. Lett. 36(8) 1335-1337 (2011)

X-ray spectrometer based on a bent diamond crystal for high repetition rate free-electron laser applications

Ulrike Boesenberg, Liubov Samoylova, Thomas Roth, Diling Zhu, Sergey Terentyev, Maurizio Vannoni, Yiping Feng, Tim Brandt van Driel, Sanghoon Song, Vladimir Blank, Harald Sinn, Aymeric Robert, and Anders Madsen
Opt. Express 25(3) 2852-2862 (2017)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.