Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of Near Infrared Spectroscopy
  • Vol. 12,
  • Issue 3,
  • pp. 167-176
  • (2004)

Experimental Design Procedures in the Calibration of Quality Parameters of Alfalfa Pellets from near Infrared Spectra

Not Accessible

Your library or personal account may give you access

Abstract

Large calibration matrices are usually needed to cover all the variability of forage samples. The present work applies experimental design techniques to reduce the number of samples necessary to calibrate quality properties of pellets of forage. Near infrared spectra were recorded from the raw material which consisted of dehydrated alfalfa milled, pressed and packed in cylindrical pellets, 5 mm in diameter. Partial least squares calibration models for moisture and crude protein, built up from 771 samples, were used as reference. Full factorial, central composite and Box–Behnken designs, using the principal components of the raw spectra as design factors were tested for sample reduction. The effect of increasing the number of replicates for each design point was also studied. Comparisons between models have been made in terms of prediction accuracy, but also looking at the model stability by means of Martens' uncertainty test. Results obtained indicate that the prediction accuracy is similar in all assayed designs and similar to that of the reference model, although the stability of the models obtained using a reduced sample set is lower. Increasing the number of replicates of the design points increases stability.

© 2004 NIR Publications

PDF Article
More Like This
Rapid determination of the main components of corn based on near-infrared spectroscopy and a BiPLS-PCA-ELM model

Lili Xu, Jinming Liu, Chunqi Wang, Zhijiang Li, and Dongjie Zhang
Appl. Opt. 62(11) 2756-2765 (2023)

Accurate wavelength calibration in the near-infrared for multielement analysis without the need for reference spectra

George Asimellis, Aggelos Giannoudakos, and Michael Kompitsas
Appl. Opt. 45(35) 8855-8862 (2006)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.