Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Journal of Near Infrared Spectroscopy
  • Vol. 19,
  • Issue 6,
  • pp. 507-519
  • (2011)

Developing Robust Faecal near Infrared Spectroscopy Calibrations to Predict Diet Dry Matter Digestibility in Cattle Consuming Tropical Forages

Not Accessible

Your library or personal account may give you access

Abstract

Various studies, mainly from temperate areas, have reported calibrations developed from the near infrared (NIR) spectra of faeces (F.NIRS) for predicting diet digestibility in ruminants and there has been substantial variation in predictive accuracy as indicated by calibration and validation statistics. The present study was conducted to develop and examine the reliability and robustness of F.NIRS calibration equations to estimate dry matter digestibility (DMD) of forage diets ingested by cattle grazing in the rangelands of northern Australia. A large and diverse calibration data set of matched diet–faecal pairs was obtained over 10 years using three sampling methods: (1) grazed pasture with diet samples collected from oesophageal fistulated steers and faeces collected from resident cattle; (2) in vivo digestibility experiments with penned cattle fed forage hays; and (3) penned cattle fed pasture freshly harvested from the field. Estimated in vivo DMD reference values were determined using pepsin–cellulase in vitro analysis of diet samples. The final calibration set of 1052 samples represented 264 diets with DMD ranging from 38% to 75%. Calibration statistics for DMD% were: standard error of calibration = 1.87, standard error of cross validation = 1.91, and the coefficient of determination, r2 = 0.90. Factors of particular importance, with regard to the accuracy of DMD reference values, are identified and discussed and recommendations made for minimising reference errors. A comprehensive series of independent validation tests was conducted by selecting validation sample sets from the entire sample set according to a range of criteria. Each validation sub-set was tested using the calibration calculated from the remainder of the sample set. These tests showed that sampling method and experimental site often had important effects on calibration statistics and performance and also that the standard error of performance of the overall calibration would likely be <2.5 DMD percentage units when applied to samples sourced from regions and pasture types represented in the calibration. Despite the large size and diversity of the calibration data set it was concluded that robustness would likely be improved by expansion of the calibration data set.

© 2011 IM Publications LLP

PDF Article
More Like This
Laser-induced breakdown spectroscopy used to detect endophyte-mediated accumulation of metals by tall fescue

Madhavi Z. Martin, Arthur J. Stewart, Kimberley D. Gwinn, and John C. Waller
Appl. Opt. 49(13) C161-C167 (2010)

Optical properties of drying wood studied by time-resolved near-infrared spectroscopy

Keiji Konagaya, Tetsuya Inagaki, Ryunosuke Kitamura, and Satoru Tsuchikawa
Opt. Express 24(9) 9561-9573 (2016)

Self-calibrating time-resolved near infrared spectroscopy

Stanislaw Wojtkiewicz, Anna Gerega, Marta Zanoletti, Aleh Sudakou, Davide Contini, Adam Liebert, Turgut Durduran, and Hamid Dehghani
Biomed. Opt. Express 10(5) 2657-2669 (2019)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.