Abstract
This paper describes a method and a precision optical sensor for remotely determining the coordinates of the center of a spherical interaction chamber (the target chamber) 10 m in diameter to within ±20 μm when the target of a multichannel laser installation intended for studies in high-temperature plasma physics is being automatically adjusted.
© 2014 Optical Society of America
PDF Article
More Like This
National Ignition Facility system alignment
S. C. Burkhart, E. Bliss, P. Di Nicola, D. Kalantar, R. Lowe-Webb, T. McCarville, D. Nelson, T. Salmon, T. Schindler, J. Villanueva, and K. Wilhelmsen
Appl. Opt. 50(8) 1136-1157 (2011)
Cited By
You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.
Contact your librarian or system administrator